{"title":"ALL PRODUCTS","description":"","products":[{"product_id":"thql32060-ge-60-amp-circuit-breaker-plug-in-60-amp-3-pole-240-volt","title":"THQL32060 - GE - 60 Amp Circuit Breaker Plug-In - 60 Amp - 3 Pole - 240 Volt","description":"\u003cdiv id=\"tabb5a7adde1af5c87d7fd797b6245c2a39\" class=\"tab-content--body\"\u003e\r\\n\r\\nGeneral Electric THQL series three pole 60 ampere plug-in molded case circuit breaker with maximum voltage rating of 240V trip type thermal magnetic common trip and standard interrupting rating of 10 kiloampere at 240V complete with (LI) long-time and instantaneous trip functions suitable for reverse feed application.\r\\n\u003cp class=\"indent\"\u003e\u003c\/p\u003e\r\\n\r\\n\u003c\/div\u003e\r\\n\u003cdiv id=\"tab17989744c0ba77bb014035ff2d0a5e50\" class=\"tab-content--body\"\u003e\r\\n\u003cdiv class=\"tab-content--heading-text\"\u003e\u003c\/div\u003e\r\\n\u003c\/div\u003e","brand":"Alpha Brokers \u0026 Controls","offers":[{"title":"New","offer_id":48395464376568,"sku":"THQL32060-N","price":61.99,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":48395464409336,"sku":"THQL32060-U","price":29.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/CB-THQL32060-1_jpg.webp?v=1778782919"},{"product_id":"bab3060h-eaton-60a-3pole-240v-bolt-on-mccb","title":"BAB3060H - Eaton - 60A 3-Pole 240V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton BAB3060H\u003c\/strong\u003e is a 3-pole, 60-amp thermal magnetic molded case circuit breaker (MCCB) rated for 240VAC with bolt-on mounting. Manufactured by Eaton (formerly Cutler-Hammer), this compact BAB-frame breaker delivers reliable overload and short-circuit protection for residential and light commercial three-phase branch circuits. Its compact, easy-to-install bolt-on design makes it a versatile and cost-effective solution for 240V load centers and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eBAB3060H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton \/ Cutler-Hammer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e10kA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eBAB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCompact bolt-on design for easy installation in Eaton BAB-frame compatible load centers and panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable time-delay overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e60-amp, 240V rating for residential and light commercial three-phase branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 240V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eHigh in-stock availability for fast replacement and new installation applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e60A three-phase branch circuit protection in 240V residential and commercial load centers\u003c\/li\u003e\n\u003cli\u003eSmall motor and equipment branch circuit protection at 240V\u003c\/li\u003e\n\u003cli\u003eHVAC compressor and equipment branch circuits\u003c\/li\u003e\n\u003cli\u003eLight commercial and residential sub-panel main protection\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Eaton BAB-frame compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton BAB3060H?\u003c\/h3\u003e\u003cp\u003eThe Eaton BAB3060H is a 60-amp, 3-pole, 240V thermal magnetic bolt-on MCCB used for branch circuit protection in three-phase residential and light commercial 240V electrical distribution systems. It is a compact, cost-effective breaker commonly used in load centers and smaller panelboards.\u003c\/p\u003e\u003ch3\u003eWhat does the H suffix mean in BAB3060H?\u003c\/h3\u003e\u003cp\u003eThe H suffix in Eaton BAB-series part numbers typically denotes a specific interrupting rating or accessory option. The BAB3060H has a standard interrupting rating of 10kA at 240V. Consult Eaton product documentation for full suffix details.\u003c\/p\u003e\u003ch3\u003eIs the BAB3060H in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls keeps the Eaton BAB3060H in stock in new condition and ships quickly. Contact us for current pricing and availability.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395478958328,"sku":"BAB3060H-N","price":79.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/CB-BAB3060H-1_1800x1800_jpg.webp?v=1778783231"},{"product_id":"hom120pcafi-square-d-homeline-arc-fault-afci-circuit-breaker-plug-in-20-amp-1-pole-120-volt","title":"HOM120PCAFI - Square D - Homeline - Arc Fault (AFCI) Circuit Breaker Plug-In - 20 Amp - 1 Pole - 120 Volt","description":"\u003cp\u003eThe Square D Homeline HOM120PCAFI is a 20 Amp, single-pole, 120 Volt combination arc fault circuit interrupter (CAFCI) breaker, engineered to detect dangerous arcing conditions and cut power before an electrical fire can start. Common causes of arc faults include furniture pressing on damaged cord insulation, a drywall screw piercing wiring, or cable punctured by a nail or staple. Every Homeline CAFCI breaker includes the built-in TIME SAVER diagnostic feature, which helps identify the type of fault that last occurred on the circuit — cutting troubleshooting time without any special tools. This is a standard plug-in breaker designed for direct installation into compatible Square D Homeline load centers.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHOM120PCAFI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHomeline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombination Arc Fault Circuit Interrupter (CAFCI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D Homeline load centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTIME SAVER fault-type diagnostic feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhat does the HOM120PCAFI protect against?\u003c\/h4\u003e\n\u003cp\u003eIt protects against arc faults — dangerous electrical arcing caused by damaged insulation, punctured cable, or a nail or screw piercing a wire — which are a leading cause of residential electrical fires.\u003c\/p\u003e\n\n\u003ch4\u003eIs this breaker compatible with any load center?\u003c\/h4\u003e\n\u003cp\u003eNo. The HOM120PCAFI is a plug-in breaker built specifically for Square D Homeline load centers. It is not designed for use in other panel series.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the TIME SAVER feature?\u003c\/h4\u003e\n\u003cp\u003eTIME SAVER is a built-in diagnostic on Homeline CAFCI breakers that helps identify the type of fault that last tripped the breaker, so troubleshooting takes less time and no additional tools are required.\u003c\/p\u003e\n\n\u003ch4\u003eIs this a new or used breaker?\u003c\/h4\u003e\n\u003cp\u003eBoth options are available: choose the New or Used variant on this listing. Used units are tested for proper function before sale.\u003c\/p\u003e\n\n\u003ch4\u003eHow do I install this breaker?\u003c\/h4\u003e\n\u003cp\u003eThis is a plug-in style breaker that snaps directly into a compatible Homeline load center slot. Installation should be performed by a qualified, licensed electrician in accordance with local electrical code.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395482890488,"sku":"HOM120PCAFI-N","price":29.99,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":48395482923256,"sku":"HOM120PCAFI-U","price":14.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/cb-chom120pcafi-1_6c1b56f0-eb3c-4117-a8fc-fa3a3043bee7_1800x1800_jpg.webp?v=1778783297"},{"product_id":"edb34125-square-d-125a-3pole-480v-bolt-on-mccb","title":"EDB34125 - Square D - 125A 3-Pole 480V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D EDB34125\u003c\/strong\u003e is a 3-pole, 125-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC with bolt-on mounting. Manufactured by Schneider Electric, this ED-frame breaker delivers reliable overcurrent and short-circuit protection for industrial and commercial three-phase feeder and main circuits at 480V. The bolt-on design ensures secure, vibration-resistant installation in compatible Square D panelboards and load centers.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEDB34125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure, vibration-resistant installation in Square D ED-frame panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e125-amp, 480V rating for medium-capacity feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole design for balanced three-phase 480V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, fully NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D ED-frame accessories including shunt trip and aux contacts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e125A feeder and main circuit protection in industrial 480V panelboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) feeder circuit breakers at 480V\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial sub-panel main protection\u003c\/li\u003e\n\u003cli\u003eManufacturing facility distribution panel branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D ED-frame bolt-on compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D EDB34125?\u003c\/h3\u003e\u003cp\u003eThe EDB34125 is a 125-amp, 3-pole, 480V thermal magnetic bolt-on MCCB from Square D used for feeder and main circuit protection in three-phase commercial and industrial 480V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eHow does EDB34125 compare to EGB34125 and EJB34125?\u003c\/h3\u003e\u003cp\u003eAll three are Square D 125A, 3-pole, 480V bolt-on thermal magnetic MCCBs, but in different frame families: EDB is ED-frame, EGB is EG-frame, and EJB is EJ-frame. Frame differences affect interrupting ratings, physical dimensions, and panelboard bus compatibility. Always confirm the correct frame for your equipment before ordering.\u003c\/p\u003e\u003ch3\u003eIs the EDB34125 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D EDB34125 in new condition. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395489902840,"sku":"EDB34125-N","price":499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/EDB34125-All-New-1.webp?v=1789095074"},{"product_id":"egb34125-square-d-125a-3pole-480v-bolt-on-mccb","title":"EGB34125 - Square D - 125A 3-Pole 480V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D EGB34125\u003c\/strong\u003e is a 3-pole, 125-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC with bolt-on mounting. Manufactured by Schneider Electric, this EG-frame breaker delivers reliable overcurrent and short-circuit protection for industrial and commercial three-phase feeder and main circuits at 480V. Its bolt-on design provides a secure, consistent installation in compatible Square D panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEGB34125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Square D EG-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e125-amp, 480V rating for feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for three-phase 480V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D EG-frame accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e125A feeder and main protection in commercial and industrial 480V panelboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) feeder circuit breakers at 480V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility sub-panel main protection\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution panel branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D EG-frame bolt-on compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D EGB34125?\u003c\/h3\u003e\u003cp\u003eThe EGB34125 is a 125-amp, 3-pole, 480V thermal magnetic bolt-on MCCB from Square D used for feeder and main circuit protection in three-phase commercial and industrial 480V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eHow does EGB34125 compare to EDB34125 and EJB34125?\u003c\/h3\u003e\u003cp\u003eAll three are Square D 125A, 3-pole, 480V bolt-on thermal magnetic MCCBs in different frame families: EG, ED, and EJ. Frame differences affect interrupting ratings, physical dimensions, and panelboard compatibility. Always confirm the required frame series for your equipment before ordering.\u003c\/p\u003e\u003ch3\u003eIs the EGB34125 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D EGB34125. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395490132216,"sku":"EGB34125-N","price":799.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/EGB34125-All-New-1.jpg?v=1778783443"},{"product_id":"ejb34125-square-d-125a-3pole-480v-bolt-on-mccb","title":"EJB34125 - Square D - 125A 3-Pole 480V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D EJB34125\u003c\/strong\u003e is a 3-pole, 125-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC with bolt-on mounting. Manufactured by Schneider Electric, this EJ-frame breaker provides reliable overload and short-circuit protection for industrial and commercial three-phase feeder and main circuits at 480V. Its bolt-on design ensures secure installation in compatible Square D panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEJB34125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eEJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Square D EJ-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e125-amp, 480V rating for medium-capacity feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 480V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D EJ-frame accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e125A feeder and main circuit protection in industrial 480V panelboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) feeder circuit protection at 480V\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution panels at 480V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility sub-panel main protection\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D EJ-frame bolt-on compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D EJB34125?\u003c\/h3\u003e\u003cp\u003eThe EJB34125 is a 125-amp, 3-pole, 480V thermal magnetic bolt-on MCCB from Square D used for feeder and main circuit protection in three-phase commercial and industrial 480V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between EJB34125, EGB34125, and EDB34125?\u003c\/h3\u003e\u003cp\u003eAll three are Square D 125-amp, 3-pole, 480V thermal magnetic bolt-on MCCBs, but in different frame families: EJB is EJ-frame, EGB is EG-frame, and EDB is ED-frame. Frame differences affect interrupting ratings, physical size, and panelboard compatibility. Select the correct frame based on your equipment's requirements.\u003c\/p\u003e\u003ch3\u003eIs the EJB34125 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D EJB34125. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395490394360,"sku":"EJB34125-N","price":1199.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/ejb34125-All-New-1.jpg?v=1778783452"},{"product_id":"ted134100wl-ge-molded-case-circuit-breaker-feed-thru-100-amp-3-pole-480-volt","title":"TED134100WL - GE - Molded Case Circuit Breaker Feed-Thru - 100 Amp - 3 Pole - 480 Volt","description":"\u003cdiv id=\"tabb5a7adde1af5c87d7fd797b6245c2a39\" class=\"tab-content--body\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv class=\"tab-content--body\" id=\"tabb5a7adde1af5c87d7fd797b6245c2a39\"\u003e\n\u003cdiv class=\"tab-content--heading-text\"\u003eDescription\u003c\/div\u003e\nBuilt to handle demanding electrical loads, the GE TED134100 is a 3-pole, 100A molded case circuit breaker. It provides reliable long-time and instantaneous protection with an 18kAIC rating at 480VAC. This bolt-on MCCB is specifically designed to integrate with GE A-Series panelboards and Spectra Series switchboards. It is HACR rated and supports reverse feed configurations. For modern upgrades, this legacy E-frame model is officially replaced by the newer TEYD3100B.\u003c\/div\u003e\n\u003cdiv class=\"tab-content--body\" id=\"tab17989744c0ba77bb014035ff2d0a5e50\"\u003e\n\u003cdiv class=\"tab-content--heading-text\"\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"md-flex jsProductUpdate jsProductReplace\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTED134100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC, 480VAC, 600VAC, 250VDC, 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAIC Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFor Use With\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eGE A-Series Panelboards, Spectra Series Switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Adjustability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Thermal, Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AWG - 3\/0 AWG (Cu), 1 AWG - 3\/0 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMin Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AWG (Cu), 1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lugs (TCAL15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 5.1, HACR, UL 489, NEMA AB 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, CSA, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemp Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e40C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstruction Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make\/Quick-Break, Trip-Free Mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395500290296,"sku":"TED134100WL-N","price":479.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/TED134100_2_e573a097-dbed-4389-bbf4-2b75db08c5c6.webp?v=1778783659"},{"product_id":"ge-ted124100-2-pole-non-interchangeable-trip-thermal-magnetic-circuit-breakers","title":"TED124100 - GE - Molded Case Circuit Breaker Feed-Thru - 100 Amp - 2 Pole - 480 Volt","description":"\u003cdiv class=\"tab-content--body\" id=\"tabb5a7adde1af5c87d7fd797b6245c2a39\"\u003e\n\u003cdiv class=\"tab-content--heading-text\"\u003eDescription\u003c\/div\u003e\nBuilt for commercial power distribution, the GE TED124100 is a 2-pole, 100A bolt-on molded case circuit breaker. It provides reliable thermal magnetic overcurrent protection within the proven E150 frame architecture. This unit installs into GE A-Series and Spectra panelboards. When modernizing older electrical systems, this legacy breaker can be substituted with the newer Tmax XT1 platform using an appropriate retrofit kit.\u003c\/div\u003e\n\u003cdiv class=\"tab-content--body\" id=\"tab17989744c0ba77bb014035ff2d0a5e50\"\u003e\n\u003cdiv class=\"tab-content--heading-text\"\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"md-flex jsProductUpdate jsProductReplace\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTED124100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC, 480VAC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAIC Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFor Use With\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eGE A-Series Panelboards, GE Spectra Panelboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Adjustability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Thermal, Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AWG - 3\/0 AWG (Cu), 1 AWG - 3\/0 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMin Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AWG (Cu), 1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Motor Operator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLugs (TCAL15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemp Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e40C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstruction Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHACR Rated, Non-Interchangeable Trip, Reverse Feed, Quick-Make\/Quick-Break, Trip-Free Mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395500880120,"sku":"TED124100-N","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/THED124045WL-Ex_e6a2e8c6-5fd0-4dbf-a0ea-330914c9396e.webp?v=1789596457"},{"product_id":"ted136030wl-ge-molded-case-circuit-breaker-feed-thru-30-amp-3-pole-600-volt","title":"TED136030WL - GE - E150 Bolt-On Molded Case Circuit Breaker with Lugs - 30 Amp - 3 Pole - 600 Volt","description":"\u003cp\u003e\u003cstrong\u003eThe GE TED136030WL is a 30A, 3-pole E150-frame molded case circuit breaker supplied with wire lugs, using bolt-on mounting and rated 600VAC for GE A-Series and Spectra Series panelboards and switchboards.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WL suffix means the breaker ships as a factory catalog number with TCAL12 wire lugs already included, so there is no separate lug kit to order or install — useful when you are stocking spares or need the unit ready to terminate on arrival. Electrically it is identical to the base TED136030: fixed thermal-magnetic Long-Time and Instantaneous (LI) protection, 18kA interrupting at 480VAC and 14kA at 600VAC, with quick-make\/quick-break contacts, a trip-free mechanism, and common trip across all three poles. HACR and HID ratings cover multi-motor HVAC equipment and high-intensity discharge lighting circuits.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGE \/ ABB (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eE150 Line, Type TED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eTED136030WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e30A (150A frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e600VAC, 480VAC, 240VAC, 500VDC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAIC Rating\u003c\/th\u003e\n\u003ctd\u003e18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC (UL 489)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Style\u003c\/th\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eWire Lugs (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eGE A-Series Panelboards, GE Spectra Series Panelboards, Switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Technology\u003c\/th\u003e\n\u003ctd\u003eThermal Magnetic (LI — Long-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Adjustability\u003c\/th\u003e\n\u003ctd\u003eFixed Thermal \/ Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWire Range\u003c\/th\u003e\n\u003ctd\u003e#14–3 AWG (Cu), #12–1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccessories Included\u003c\/th\u003e\n\u003ctd\u003eTCAL12 Wire Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable Options\u003c\/th\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL 489, CSA C22.2 No. 5, NEMA AB 1, HACR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConstruction Features\u003c\/th\u003e\n\u003ctd\u003eHACR Rated, HID Rated, Common Trip, Quick-Make\/Quick-Break, Trip-Free Mechanism, Reverse Feed Capable, Non-Interchangeable Trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Dimensions\u003c\/th\u003e\n\u003ctd\u003e10 x 8 x 8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Weight\u003c\/th\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat does the WL suffix mean on the TED136030WL?\u003c\/h3\u003e\n\u003cp\u003eWL stands for \"with lugs.\" The breaker is a factory catalog number that ships with TCAL12 wire lugs included, rather than requiring a separately ordered lug kit.\u003c\/p\u003e\n\u003ch3\u003eIs the TED136030WL interchangeable with the TED136030?\u003c\/h3\u003e\n\u003cp\u003eYes. The breakers are electrically and mechanically identical; the only difference is factory-supplied lugs.\u003c\/p\u003e\n\u003ch3\u003eWhat is the interrupting rating of the TED136030WL?\u003c\/h3\u003e\n\u003cp\u003e18kA at 240VAC and 480VAC, 14kA at 600VAC, and 10kA at 250VDC and 500VDC.\u003c\/p\u003e\n\u003ch3\u003eWhat wire sizes do the included lugs accept?\u003c\/h3\u003e\n\u003cp\u003eTCAL12 lugs accept #14–3 AWG copper or #12–1 AWG aluminum conductors.\u003c\/p\u003e\n\u003ch3\u003eWhat panelboards does the TED136030WL fit?\u003c\/h3\u003e\n\u003cp\u003eGE A-Series and Spectra Series panelboards and switchboards using bolt-on mounting.\u003c\/p\u003e\n\u003ch3\u003eCan the TED136030WL be reverse fed?\u003c\/h3\u003e\n\u003cp\u003eYes. Reverse feed is permitted with no line\/load marking restriction under UL 489.\u003c\/p\u003e\n\u003ch3\u003eIs the 30A trip rating adjustable?\u003c\/h3\u003e\n\u003cp\u003eNo. The trip unit is fixed and non-interchangeable.\u003c\/p\u003e\n\u003ch3\u003eIs the TED136030WL UL listed?\u003c\/h3\u003e\n\u003cp\u003eYes. It is UL 489 listed, CSA certified to C22.2 No. 5, and HACR rated.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395500945656,"sku":"TED136030WL-N","price":399.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/TED136030WL-GE-MoldedCaseCircuitBreakerFeed-Thru-30Amp-3Pole-600Volt.webp?v=1786726846"},{"product_id":"ted136050wl-ge-molded-case-circuit-breaker-feed-thru-50-amp-3-pole-600-volt","title":"TED136050WL - GE - E150 Bolt-On Molded Case Circuit Breaker with Lugs - 50 Amp - 3 Pole - 600 Volt","description":"\u003cp\u003e\u003cstrong\u003eThe GE TED136050WL is a 50A, 3-pole E150-frame molded case circuit breaker supplied with wire lugs, using bolt-on mounting and rated 600VAC for GE A-Series and Spectra panelboards, switchboards, and motor control centers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe WL suffix identifies a factory catalog number that ships with TCAL12 wire lugs already included — no separate lug kit to source, which matters when you are buying spares or need a unit ready to terminate on arrival. Electrically it matches the base TED136050: fixed thermal-magnetic Long-Time and Instantaneous (LI) protection with an 18kA interrupting rating at 480VAC and 14kA at 600VAC. The bolt-on bus connection resists loosening under vibration, making it the standard choice for MCC buckets and switchboard sections. HACR and HID rated with reverse-feed capability.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGE \/ ABB (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eE150 Line, Type TED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eTED136050WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e50A (150A frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e600VAC, 480VAC, 240VAC, 500VDC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAIC Rating\u003c\/th\u003e\n\u003ctd\u003e18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC (UL 489)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Style\u003c\/th\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eWire Lugs (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eGE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers, E150 Enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Technology\u003c\/th\u003e\n\u003ctd\u003eThermal Magnetic (LI — Long-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Adjustability\u003c\/th\u003e\n\u003ctd\u003eFixed Thermal \/ Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWire Range\u003c\/th\u003e\n\u003ctd\u003e#14–2 AWG (Cu), #12–2 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccessories Included\u003c\/th\u003e\n\u003ctd\u003eTCAL12 Wire Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable Options\u003c\/th\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL 489, CSA C22.2 No. 5, NEMA AB 1, HACR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eUL, CSA, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConstruction Features\u003c\/th\u003e\n\u003ctd\u003eHACR Rated, HID Rated, Reverse Feed Capable, Non-Interchangeable Trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Dimensions\u003c\/th\u003e\n\u003ctd\u003e12 x 9 x 9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Weight\u003c\/th\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat does the WL suffix mean on the TED136050WL?\u003c\/h3\u003e\n\u003cp\u003eWL stands for \"with lugs.\" It is a factory catalog number that includes TCAL12 wire lugs, rather than requiring a separately ordered lug kit.\u003c\/p\u003e\n\u003ch3\u003eIs the TED136050WL interchangeable with the TED136050?\u003c\/h3\u003e\n\u003cp\u003eYes. The two are electrically and mechanically identical; the only difference is factory-supplied lugs.\u003c\/p\u003e\n\u003ch3\u003eWhat is the interrupting rating of the TED136050WL?\u003c\/h3\u003e\n\u003cp\u003e18kA at 240VAC and 480VAC, 14kA at 600VAC, and 10kA at 250VDC and 500VDC.\u003c\/p\u003e\n\u003ch3\u003eWhen should I use a THED instead?\u003c\/h3\u003e\n\u003cp\u003eIf your fault-current study shows more than 18kA available at the panel. The THED is the high-interrupting version of the same E150 frame, rated 25kA at 480VAC and 65kA at 240VAC.\u003c\/p\u003e\n\u003ch3\u003eWhat wire sizes do the included lugs accept?\u003c\/h3\u003e\n\u003cp\u003e#14–2 AWG copper or #12–2 AWG aluminum conductors.\u003c\/p\u003e\n\u003ch3\u003eCan the TED136050WL be reverse fed?\u003c\/h3\u003e\n\u003cp\u003eYes. Reverse feed is permitted with no line\/load marking restriction under UL 489.\u003c\/p\u003e\n\u003ch3\u003eIs the 50A trip rating adjustable?\u003c\/h3\u003e\n\u003cp\u003eNo. The trip unit is fixed and non-interchangeable.\u003c\/p\u003e\n\u003ch3\u003eIs the TED136050WL UL listed?\u003c\/h3\u003e\n\u003cp\u003eYes. It is UL 489 listed, CSA certified to C22.2 No. 5, CE marked, and HACR rated.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395501142264,"sku":"TED136050WL-N","price":449.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/62.png?v=1784933508"},{"product_id":"thed136020wl-ge-molded-case-circuit-breaker-feed-thru-20-amp-3-pole-600-volt","title":"THED136020WL - GE - Molded Case Circuit Breaker Feed-Thru - 20 Amp - 3 Pole - 600 Volt","description":"\u003cdiv class=\"tab-content--body\" id=\"tabb5a7adde1af5c87d7fd797b6245c2a39\"\u003e\n\u003cdiv class=\"tab-content--heading-text\"\u003eDescription\u003c\/div\u003e\nEngineered for commercial applications, the THED136020 is a 3-pole, 20A molded case circuit breaker from GE's E-Frame family. It provides reliable thermal-magnetic protection with fixed long-time and instantaneous trip functions. This bolt-on MCCB is designed to mount into GE A-Series and Spectra Series panelboards, as well as motor control centers. It serves as a high-interrupting replacement for standard TED136020 breakers. Rated for 600VAC, it delivers 25kAIC at 480V and is HACR certified.\u003c\/div\u003e\n\u003cdiv class=\"tab-content--body\" id=\"tab17989744c0ba77bb014035ff2d0a5e50\"\u003e\n\u003cdiv class=\"tab-content--heading-text\"\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"md-flex jsProductUpdate jsProductReplace\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED136020-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC, 480VAC, 600VAC, 250VDC, 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAIC Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFor Use With\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eGE A-Series Panelboards, GE Spectra Series Panelboards, Motor Control Centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Adjustability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Thermal, Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e14-3 AWG (Cu), 12-1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AWG (Cu), 1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMin Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG (Cu), 12 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Lugs (TCAL12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 5, NEMA AB 1, UL 489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, HACR, HID, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemp Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e40C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstruction Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHACR Rated, High Interrupting Capacity, Reverse Feed, Non-Interchangeable Trip, Common Trip, Quick-Make\/Quick-Break, Trip-Free Mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395501371640,"sku":"THED136020WL-N","price":649.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/3Ss7wbp2-THED136020WL_1_e046e0b2-4d66-48cc-b3e0-1c67342f5e45.webp?v=1778783679"},{"product_id":"thed136030wl-ge-30a-3pole-600v-feed-thru-wire-lug-mccb","title":"THED136030WL - GE - 30A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eGE THED136030WL\u003c\/strong\u003e is a 3-pole, 30-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting and factory-installed wire lugs. Manufactured by General Electric (now ABB), the THED series is a proven choice for commercial and industrial branch circuit and feeder protection in three-phase 600V systems. The WL suffix indicates factory-installed wire lugs for simplified conductor termination during installation.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eTHED136030WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE \/ ABB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Option\u003c\/td\u003e\n\u003ctd\u003eWire Lug (WL) — Factory Installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 18kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eTHED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFactory-installed wire lugs (WL) for simplified, code-compliant conductor termination\u003c\/li\u003e\n\u003cli\u003eFeed-through mounting for main circuit breaker and service entrance applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e30-amp, 600V rating for three-phase branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30A main and branch circuit protection in 600V three-phase panelboards\u003c\/li\u003e\n\u003cli\u003eService entrance protection for light industrial facilities\u003c\/li\u003e\n\u003cli\u003eCommercial building sub-panel main breakers at 600V\u003c\/li\u003e\n\u003cli\u003eSmall motor branch circuit protection\u003c\/li\u003e\n\u003cli\u003eReplacement in GE\/ABB THED-frame feed-through panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the GE THED136030WL?\u003c\/h3\u003e\u003cp\u003eThe GE THED136030WL is a 30-amp, 3-pole, 600V thermal magnetic feed-through MCCB with factory-installed wire lugs, used to protect three-phase branch circuits and feeders in commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does WL mean on the THED136030WL?\u003c\/h3\u003e\u003cp\u003eWL stands for Wire Lug — the breaker comes with factory-installed lug terminals on both line and load sides, making conductor termination easier and faster compared to the base THED136030 which requires separate lug accessories.\u003c\/p\u003e\u003ch3\u003eIs THED136030WL the same as THED136030?\u003c\/h3\u003e\u003cp\u003eBoth are electrically identical 30A, 3-pole, 600V thermal magnetic feed-through MCCBs. The only difference is the WL suffix indicates factory-installed wire lugs are included on the THED136030WL, while the base THED136030 does not include them.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395501404408,"sku":"THED136030WL-N","price":668.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260204_214620.jpg?v=1778783681"},{"product_id":"thed136050wl-ge-molded-case-circuit-breaker-feed-thru-50-amp-3-pole-600-volt","title":"THED136050WL - GE - E150 High-Interrupting Bolt-On Circuit Breaker with Lugs - 50 Amp - 3 Pole - 600 Volt","description":"\u003cp\u003e\u003cstrong\u003eThe GE THED136050WL is a 50A, 3-pole E150-frame high-interrupting molded case circuit breaker supplied with wire lugs, using bolt-on mounting and rated 600VAC for GE A-Series and Spectra Series panelboards.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis catalog number combines the two options most often needed on a 50A three-phase feeder. The H marks the high-interrupting version of the E150 frame — 65kA at 240VAC and 25kA at 480VAC, well beyond the standard TED's 18kA — for installations where the available fault current is substantial. The WL suffix means wire lugs ship in the box, so the breaker is ready to terminate without a separate accessory order. Protection is fixed thermal-magnetic Long-Time and Instantaneous (LI), with quick-make\/quick-break contacts, a trip-free mechanism, and common trip across all three poles.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGE \/ ABB (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eE150 Line, Type THED (High Interrupting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eTHED136050WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e50A (150A frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e600VAC, 480VAC, 240VAC, 500VDC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAIC Rating\u003c\/th\u003e\n\u003ctd\u003e65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC (UL 489)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Style\u003c\/th\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eWire Lugs (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eGE A-Series Panelboards, GE Spectra Series Panelboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Technology\u003c\/th\u003e\n\u003ctd\u003eThermal Magnetic (LI — Long-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Adjustability\u003c\/th\u003e\n\u003ctd\u003eFixed Thermal \/ Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWire Range\u003c\/th\u003e\n\u003ctd\u003e#14–3 AWG (Cu), #12–1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccessories Included\u003c\/th\u003e\n\u003ctd\u003eWire Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable Options\u003c\/th\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment, Alarm Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL 489, CSA C22.2 No. 5, NEMA AB 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eUL, CSA, HACR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConstruction Features\u003c\/th\u003e\n\u003ctd\u003eHigh Interrupting Capacity, HACR Rated, Common Trip, Quick-Make\/Quick-Break, Trip-Free Mechanism, Reverse Feed Capable, Non-Interchangeable Trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Dimensions\u003c\/th\u003e\n\u003ctd\u003e10 x 8 x 8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Weight\u003c\/th\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat does WL mean on the THED136050WL?\u003c\/h3\u003e\n\u003cp\u003eWL stands for \"with lugs.\" It is a factory catalog number that includes wire lugs, so no separate lug kit is required.\u003c\/p\u003e\n\u003ch3\u003eIs the THED136050WL interchangeable with the THED136050?\u003c\/h3\u003e\n\u003cp\u003eYes. The two are electrically and mechanically identical; only the factory-supplied lugs differ.\u003c\/p\u003e\n\u003ch3\u003eWhat is the interrupting rating of the THED136050WL?\u003c\/h3\u003e\n\u003cp\u003e65kA at 240VAC, 25kA at 480VAC, 18kA at 600VAC, and 10kA at 250VDC and 500VDC.\u003c\/p\u003e\n\u003ch3\u003eHow does this differ from a TED136050WL?\u003c\/h3\u003e\n\u003cp\u003eInterrupting capacity only. The THED is rated 25kA at 480VAC versus the TED's 18kA, in the same frame and footprint.\u003c\/p\u003e\n\u003ch3\u003eWhat wire sizes do the included lugs accept?\u003c\/h3\u003e\n\u003cp\u003e#14–3 AWG copper or #12–1 AWG aluminum conductors.\u003c\/p\u003e\n\u003ch3\u003eCan the THED136050WL be reverse fed?\u003c\/h3\u003e\n\u003cp\u003eYes. Reverse feed is permitted with no line\/load marking restriction under UL 489.\u003c\/p\u003e\n\u003ch3\u003eIs the 50A trip rating adjustable?\u003c\/h3\u003e\n\u003cp\u003eNo. The trip unit is fixed and non-interchangeable.\u003c\/p\u003e\n\u003ch3\u003eIs the THED136050WL UL listed?\u003c\/h3\u003e\n\u003cp\u003eYes. It is UL 489 listed, CSA certified to C22.2 No. 5, and HACR rated.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395501437176,"sku":"THED136050WL-N","price":694.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/ChatGPTImageAug14_2026_12_28_12PM.png?v=1786724907"},{"product_id":"thqb32060-ge-60-amp-3-pole-bolt-on-circuit-breaker","title":"THQB32060 - GE - 60 Amp 3 Pole Bolt-On Circuit Breaker","description":"\u003cp\u003eGeneral Electric THQB series three pole 60 ampere bolt-on molded case circuit breaker with maximum voltage rating of 240V tripping method thermal magnetic and standard interrupting rating of 10 kiloampere at 208V functions long-time and instantaneous used on AQ panelboards.\u003c\/p\u003e","brand":"Alpha Brokers \u0026 Controls","offers":[{"title":"New","offer_id":48395505565944,"sku":"THQB32060-N","price":127.99,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":48395505598712,"sku":"THQB32060-U","price":64.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/CB-THQB32060-1_1800x1800_jpg.webp?v=1778783704"},{"product_id":"hfd2150-eaton-150a-2pole-600v-bolt-on-mccb","title":"HFD2150 - Eaton - 150A 2-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton HFD2150\u003c\/strong\u003e is a 2-pole, 150-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. Manufactured by Eaton (formerly Cutler-Hammer), this HFD-frame, 2-pole breaker delivers reliable overcurrent and short-circuit protection for single-phase and two-wire feeder and branch circuits in commercial and industrial 600V power distribution systems. Available in reconditioned condition for cost-effective replacement applications.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHFD2150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton \/ Cutler-Hammer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e2-pole configuration for single-phase and two-wire 150A circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Eaton\/Cutler-Hammer HFD-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e150-amp, 600V rating for medium-capacity feeder and branch circuits\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eAvailable in used\/reconditioned condition — tested and inspected prior to shipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e150A single-phase feeder circuit protection in 600V commercial and industrial panels\u003c\/li\u003e\n\u003cli\u003eTwo-wire large equipment and motor circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial building single-phase distribution circuits at 600V\u003c\/li\u003e\n\u003cli\u003eIndustrial control and equipment branch circuit protection\u003c\/li\u003e\n\u003cli\u003eReplacement in Eaton HFD-frame 2-pole compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton HFD2150?\u003c\/h3\u003e\u003cp\u003eThe Eaton HFD2150 is a 150-amp, 2-pole, 600V thermal magnetic bolt-on MCCB used for overcurrent and short-circuit protection of single-phase and two-wire feeder and branch circuits in commercial and industrial 600V electrical systems.\u003c\/p\u003e\u003ch3\u003eIs the HFD2150 available new or used?\u003c\/h3\u003e\u003cp\u003eAlpha Brokers \u0026amp; Controls stocks the Eaton HFD2150 in used\/reconditioned condition. All used circuit breakers are tested and inspected before shipping to ensure reliable performance.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between HFD2150 (2-pole) and a 3-pole HFD breaker?\u003c\/h3\u003e\u003cp\u003eA 2-pole HFD breaker like the HFD2150 protects two conductors in single-phase or two-wire applications, while a 3-pole HFD breaker protects three conductors in three-phase circuits. Select based on your circuit's phase configuration.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Used","offer_id":48395540234488,"sku":"HFD2150-U","price":364.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HFD2150-All-New-1_522d0ab4-5023-4def-bd48-ac6c47576560.jpg?v=1778784199"},{"product_id":"ge-sela36at0030-3-pole-interchangeable-trip-electronic-cb-frames-only","title":"SELA36AT0030 - GE - Molded Case Circuit Breaker Bolt-On - 30 Amp - 3 Pole - 600 Volt","description":"\u003cp\u003eMOLDED CASE ELECTRONIC SOLID STATE TRIP CURRENT LIMITING TYPE 4.12 INCH WIDTH X 3.38 INCH DEPTH X 6.31 INCH HEIGHT SIZE 600 VOLT MAX. AC VOLTAGE RATING UL CSA APPROVAL 600 VOLT AC VOLTAGE RATING 100 KILOAMP AT 240 VOLT AC 65 KILOAMP AT 480 VOLT AC 25 KILOAMP AT 600 VOLT AC (UL) 100 KILOAMP AT 220 TO 240 VOLT AC 20 KILOAMP AT 380 TO 415 VOLT AC 8 KILOAMP AT 500 VOLT AC 3 KILOAMP AT 690 VOLT AC (IEC) INTERRUPTING RATING 30 AMP CURRENT RATING 3 POLE(S) E FRAME TYPE BUYLOG  SPECTRA RMS BRAND TRIP FUNCTION LSI WIRE SIZE 12 TO 3\/0 AWG (COPPER\/ALUMINUM) INCLUDES LONG\/SHORT\/INSTANTANEOUS TIME TRIP APPLICATION HEATING AIR CONDITIONING REFRIGERATION APPLICABLE STANDARD IEC SHL MODEL\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395556225272,"sku":"SELA36AT0030-N","price":499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/SELA36AT0030.webp?v=1790112213"},{"product_id":"thed136100-ge-molded-case-circuit-breaker-feed-thru-100-amp-3-pole-600-volt","title":"THED136100 - GE - Molded Case Circuit Breaker Feed-Thru - 100 Amp - 3 Pole - 600 Volt","description":"\u003cdiv class=\"product-description\"\u003e\n\u003cp\u003eThe General Electric THED136100 is a 3-pole, 100-amp molded case circuit breaker rated for 600V AC, built for reliable overcurrent protection in industrial and commercial electrical systems. Part of GE's E150 Line, this THED-series breaker uses thermal magnetic (LI) trip technology in a Feed-Thru, bolt-on configuration, allowing it to pass power through a panel section to a secondary compartment — a common setup in switchboards and panelboards that need through-feed distribution. Long-time and instantaneous trip functions guard connected loads against both sustained overloads and short-circuit faults, while an interrupting rating up to 65kA at 240V and 25kA at 480V gives it the fault-clearing capacity industrial panels demand. Every unit ships new and UL listed, ready to install.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eTHED136100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries \/ Family\u003c\/td\u003e\n\u003ctd\u003eTHED, E150 Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eMolded case, fixed thermal magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru, Bolt-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e100 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600V AC (120\/240\/277\/480 VAC; 125\/250 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating (AIC)\u003c\/td\u003e\n\u003ctd\u003e65 kA @ 240VAC · 25 kA @ 480VAC · 10 kA @ 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Functions\u003c\/td\u003e\n\u003ctd\u003eLI — Long-Time \u0026amp; Instantaneous (Thermal Magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eNon-interchangeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eAluminum\/Copper Line \u0026amp; Load Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 4-1\/8\" W x 3-3\/8\" D x 6-5\/16\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhat is the GE THED136100 used for?\u003c\/h3\u003e\n\u003cp\u003eIt's used to provide 3-phase overcurrent protection on 600V-class electrical systems, typically as a feeder or main breaker in industrial and commercial panelboards and switchboards.\u003c\/p\u003e\n\n\u003ch3\u003eWhat does \"Feed-Thru\" mean on this breaker?\u003c\/h3\u003e\n\u003cp\u003eFeed-Thru refers to a mounting configuration that lets power pass through the breaker's compartment to a downstream section of the panel, rather than terminating there — useful in switchboards that need to distribute power to additional sections.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the interrupting rating of the THED136100?\u003c\/h3\u003e\n\u003cp\u003eIt's rated to interrupt up to 65kA at 240VAC, 25kA at 480VAC, and 10kA at 250VDC, giving it enough fault-clearing capacity for most industrial 480V distribution systems.\u003c\/p\u003e\n\n\u003ch3\u003eIs the GE THED136100 UL listed?\u003c\/h3\u003e\n\u003cp\u003eYes. It's UL listed and suitable for HACR (heating, air conditioning, and refrigeration) duty applications.\u003c\/p\u003e\n\n\u003ch3\u003eDoes this breaker use a fixed or interchangeable trip unit?\u003c\/h3\u003e\n\u003cp\u003eIt uses a non-interchangeable thermal magnetic trip unit, meaning the trip settings are factory-fixed rather than field-adjustable.\u003c\/p\u003e\n\n\u003ch3\u003eIs this a new or refurbished unit?\u003c\/h3\u003e\n\u003cp\u003eThis listing is for a new GE THED136100, not a reconditioned or surplus unit.\u003c\/p\u003e","brand":"Alpha Brokers \u0026 Controls","offers":[{"title":"New","offer_id":48395561599224,"sku":"THED136100-N","price":708.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/THED136100-R_a36d1964-4901-46b0-b4ae-82f9da259b81.webp?v=1778784604"},{"product_id":"hgb2b100b-siemens-100a-2pole-600v-bolt-on-mccb","title":"HGB2B100B - Siemens - 100A 2-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens HGB2B100B\u003c\/strong\u003e is a 2-pole, 100-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. This HGB-frame, 2-pole breaker delivers reliable overcurrent and short-circuit protection for single-phase and two-phase branch and feeder circuits in commercial and industrial 600V power distribution systems. Its bolt-on design provides a secure installation in compatible Siemens panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHGB2B100B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e2-pole design for single-phase and two-wire 100A circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Siemens HGB-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e100-amp, 600V rating for medium-capacity branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompact HGB frame for efficient switchboard installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e100A single-phase feeder and branch circuit protection in 600V panels\u003c\/li\u003e\n\u003cli\u003eTwo-wire equipment and motor circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial single-phase distribution circuits\u003c\/li\u003e\n\u003cli\u003eControl equipment and instrumentation panel feeders\u003c\/li\u003e\n\u003cli\u003eReplacement in Siemens HGB-frame 2-pole compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Siemens HGB2B100B?\u003c\/h3\u003e\u003cp\u003eThe Siemens HGB2B100B is a 100-amp, 2-pole, 600V thermal magnetic bolt-on MCCB used for overcurrent and short-circuit protection of single-phase and two-wire branch and feeder circuits in commercial and industrial 600V electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between HGB2B100B (2-pole) and HGB3B020B (3-pole)?\u003c\/h3\u003e\u003cp\u003eThe HGB2B100B is a 2-pole, 100A breaker for single-phase and two-wire circuits, while HGB3B020B is a 3-pole, 20A breaker for three-phase circuits. Both are Siemens HGB-frame bolt-on MCCBs, but differ in pole count and amperage rating.\u003c\/p\u003e\u003ch3\u003eIs the HGB2B100B in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Siemens HGB2B100B. Contact us for current availability and pricing.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395578343672,"sku":"HGB2B100B-N","price":214.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260210_231928.jpg?v=1778784890"},{"product_id":"hgb3b020b-siemens-20a-3pole-600v-bolt-on-mccb","title":"HGB3B020B - Siemens - 20A 3-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens HGB3B020B\u003c\/strong\u003e is a 3-pole, 20-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. This HGB-frame breaker delivers reliable overload and short-circuit protection for commercial and industrial three-phase branch circuits at 600V. Its bolt-on design ensures secure, vibration-resistant installation in compatible Siemens panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHGB3B020B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Siemens HGB-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e20-amp, 600V rating for light commercial and industrial three-phase branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V circuit protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompact HGB frame for space-efficient installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e20A three-phase branch circuit protection in 600V commercial and industrial panels\u003c\/li\u003e\n\u003cli\u003eControl panel and small equipment branch circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eLight industrial branch circuits and instrumentation feeders\u003c\/li\u003e\n\u003cli\u003eManufacturing facility small branch circuit distribution\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Siemens HGB-frame compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Siemens HGB3B020B?\u003c\/h3\u003e\u003cp\u003eThe Siemens HGB3B020B is a 20-amp, 3-pole, 600V thermal magnetic bolt-on MCCB used for branch circuit protection in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does the B suffix mean in HGB3B020B?\u003c\/h3\u003e\u003cp\u003eIn Siemens HGB-series part numbers, the trailing B typically indicates a specific factory-configured terminal or mounting option. Consult Siemens product documentation for the full suffix breakdown for this model.\u003c\/p\u003e\u003ch3\u003eIs the HGB3B020B in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Siemens HGB3B020B. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395579916536,"sku":"HGB3B020B-N","price":299.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260210_234150.jpg?v=1778784923"},{"product_id":"jxd63b400-siemens-400a-3pole-600v-bolt-on-mccb","title":"JXD63B400 - Siemens - 400A 3-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens JXD63B400\u003c\/strong\u003e is a 3-pole, 400-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. Engineered for heavy industrial and commercial three-phase power distribution, this JXD-frame breaker delivers high-capacity overload and short-circuit protection for large feeder and main circuits. The bolt-on design provides a secure, vibration-resistant installation in compatible Siemens panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJXD63B400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 35kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJXD6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on design for secure installation in Siemens JXD-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e400A high-capacity rating for main and large feeder circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V industrial distribution systems\u003c\/li\u003e\n\u003cli\u003eHigh interrupting capacity for demanding industrial environments\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e400A main and large feeder circuit protection in industrial 600V panelboards\u003c\/li\u003e\n\u003cli\u003eHeavy manufacturing plant main distribution protection\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) main incoming feeder protection\u003c\/li\u003e\n\u003cli\u003eIndustrial switchboard main circuit breaker applications\u003c\/li\u003e\n\u003cli\u003eUtility and process industry high-capacity power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Siemens JXD63B400?\u003c\/h3\u003e\u003cp\u003eThe Siemens JXD63B400 is a 400-amp, 3-pole, 600V thermal magnetic bolt-on MCCB used as a main or large feeder circuit breaker in heavy industrial and commercial three-phase 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat panelboards are compatible with the JXD63B400?\u003c\/h3\u003e\u003cp\u003eThe JXD63B400 uses bolt-on mounting and is compatible with Siemens JXD6-frame panelboards and switchboards. Always verify frame and bus compatibility with your specific equipment before installation.\u003c\/p\u003e\u003ch3\u003eIs the JXD63B400 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Siemens JXD63B400 in new condition and ships quickly. Contact us for current pricing and availability.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395582210296,"sku":"JXD63B400-N","price":1199.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/shopping-scaled.jpg?v=1778784946"},{"product_id":"lgb3b090b-siemens-90a-3pole-600v-bolt-on-mccb","title":"LGB3B090B - Siemens - 90A 3-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens LGB3B090B\u003c\/strong\u003e is a 3-pole, 90-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. Engineered for industrial and commercial three-phase power distribution, this LGB-frame breaker delivers reliable overload and short-circuit protection. Its bolt-on design provides a secure, vibration-resistant connection in compatible Siemens panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLGB3B090B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e90A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eLGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on design for secure, vibration-resistant mounting in Siemens-compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable time-delay overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e90-amp, 600V rating for industrial and commercial branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003e3-pole design for balanced three-phase 600V protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eField-installable accessories available for enhanced functionality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e90A three-phase branch and feeder circuit protection in 600V industrial panels\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit and feeder protection in switchboards\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution panels up to 600V\u003c\/li\u003e\n\u003cli\u003eHVAC and process equipment feeders at 600V\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Siemens LGB-frame compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Siemens LGB3B090B?\u003c\/h3\u003e\u003cp\u003eThe Siemens LGB3B090B is a 90-amp, 3-pole, 600V thermal magnetic bolt-on MCCB used for branch circuit and feeder protection in three-phase industrial and commercial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does the B suffix mean in LGB3B090B?\u003c\/h3\u003e\u003cp\u003eThe B suffix in Siemens LGB-series part numbers typically indicates a specific terminal or accessory configuration. Consult Siemens product documentation for the exact meaning and available options for this model.\u003c\/p\u003e\u003ch3\u003eIs the LGB3B090B in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Siemens LGB3B090B. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395584045304,"sku":"LGB3B090B-N","price":249.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/8OqVHdzS-LGB3B090B-All-New-1_4d5b4ac0-f708-4b34-a893-961edbd727ce.jpg?v=1778784971"},{"product_id":"schneider-electric-bda36050-3-pole-non-interchangeable-trip-thermal-magnetic-circuit-breakers","title":"BDA36050 - Square D - 3-Pole 50A Thermal Magnetic Circuit Breaker — PowerPacT B, I-Line, Non-Interchangeable Trip","description":"\u003cp\u003eThe Schneider Electric BDA36050 is a 3-pole, 50A PowerPacT B-Frame molded case circuit breaker built for reliable overload and short-circuit protection in commercial and industrial power distribution systems. It features a non-interchangeable thermal magnetic trip unit with Long-Time and Instantaneous (LI) protection functions, dual-break rotating contacts to reduce peak current during short-circuit events, and an I-Line style plug-in mounting design with ABC phase connection for fast installation into compatible panelboards. The load side terminates in mechanical lugs, and the breaker includes an integral push-to-trip button for manual testing. Rated 600Y\/347VAC and UL 489 listed, the BDA36050 is a direct fit replacement or new-install option for facilities standardizing on Square D PowerPacT B distribution equipment.\u003c\/p\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowerPacT B-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBDA36050\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600Y\/347 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Rating (AIC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kA @ 240VAC | 18kA @ 480VAC | 14kA @ 600Y\/347VAC | 10kA @ 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic, Non-Interchangeable, LI (Long-Time + Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80% Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixed Magnetic Trip\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHold: 480A \/ Trip: 720A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In, ABC Phase Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine (ON end): I-Line \/ Load (OFF end): Mechanical Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWG 14 – AWG 2\/0, Aluminum\/Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles @ 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards \/ Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed, CSA Certified, IEC Rated, NOM, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e137mm x 81mm x 89mm (5.39\" x 3.19\" x 3.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.315 kg (2.9 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhat does \"non-interchangeable trip\" mean on the BDA36050?\u003c\/h3\u003e\n\u003cp\u003eIt means the thermal magnetic trip unit is factory-set and permanently fixed to the breaker frame — it cannot be swapped for a different trip rating like interchangeable-trip breakers allow. This makes it a fixed 50A trip breaker.\u003c\/p\u003e\n\n\u003ch3\u003eWhat panels is the BDA36050 compatible with?\u003c\/h3\u003e\n\u003cp\u003eThe BDA36050 uses I-Line style plug-in mounting with ABC phase connection, designed for Square D I-Line panelboards and switchboards rated for PowerPacT B-Frame breakers.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the interrupting (AIC) rating of this breaker?\u003c\/h3\u003e\n\u003cp\u003eIt's rated 14kA at 600Y\/347VAC, 18kA at 480VAC, 25kA at 240VAC, and 10kA at 250VDC, per UL 489.\u003c\/p\u003e\n\n\u003ch3\u003eIs the BDA36050 UL listed?\u003c\/h3\u003e\n\u003cp\u003eYes. It's UL 489 Listed and also CSA Certified and IEC Rated for use in commercial and industrial distribution equipment.\u003c\/p\u003e\n\n\u003ch3\u003eWhat size wire does the BDA36050 accept?\u003c\/h3\u003e\n\u003cp\u003eThe load-side mechanical lugs accept AWG 14 through AWG 2\/0 aluminum or copper conductors.\u003c\/p\u003e\n\n\u003ch3\u003eCan I test the BDA36050 without removing it from the panel?\u003c\/h3\u003e\n\u003cp\u003eYes, it includes an integral push-to-trip button for manual trip testing without de-energizing or removing the breaker.\u003c\/p\u003e\n","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395599937784,"sku":"BDA36050-N","price":474.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/BDA36050-1.webp?v=1786137972"},{"product_id":"square-d-bda36125-3-pole-non-interchangeable-trip-thermal-magnetic-circuit-breakers","title":"BDA36125 - Square D - 3 Pole Non-Interchangeable Trip Thermal Magnetic Circuit Breakers","description":"\u003cp\u003eTHERMAL MAGNETIC TYPE 3.19 INCH WIDTH X 3.5 INCH DEPTH X 5.39 INCH HEIGHT SIZE 347 VOLT MAX. AC VOLTAGE RATING 250 VOLT MAX. DC VOLTAGE RATING UL CSA CE APPROVAL 600 STAR\/347 VOLT AC 50\/60 HERTZ 250 VOLT DC VOLTAGE RATING 14 KILOAMP AT 600 STAR\/347 VOLT AC 10 KILOAMP AT 250 VOLT DC INTERRUPTING RATING 125 AMP CURRENT RATING 3 POLE(S) I-LINE CONNECTION LINE LUG LOAD TERMINAL TYPE B FRAME TYPE POWERPACT[TM] BRAND ROHS\/REACH COMPLIANT TRIP SETTING 1000 AMP (HOLD) 1500 AMP (TRIP) MOUNTING TYPE I-LINE CONTROL TYPE TOGGLE TERMINAL WIRE SIZE 14 TO 2\/0 AWG (COPPER\/ALUMINUM) CONTINUOUS CURRENT RATING 80 PERCENT PHASE CONNECTION TYPE ABC OPERATION AMBIENT AIR TEMPERATURE RATING -13 TO 158 DEG F APPLICATION DISTRIBUTION APPLICABLE STANDARD EAC NOM IEC CCC NEMA AB1 EN\/IEC 60947-2\/60947-5-1 NMX J-266 GB 14048.2 BD MODEL\u003c\/p\u003e","brand":"Alpha Brokers \u0026 Controls","offers":[{"title":"New","offer_id":48395600331000,"sku":"BDA36125-N","price":664.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/BDA36050-1_a18278bd-b9df-4568-8f13-3ad1229da609.webp?v=1786138133"},{"product_id":"schneider-electric-bja36015-3-pole-din-rail-mount-circuit-breakers","title":"BJA36015 - Square D - 3 Pole Din Rail Mount Circuit Breakers","description":"\u003cp\u003eTHERMAL MAGNETIC TYPE 3.19 INCH WIDTH X 3.5 INCH DEPTH X 5.39 INCH HEIGHT SIZE 347 VOLT MAX. AC VOLTAGE RATING 250 VOLT MAX. DC VOLTAGE RATING UL CSA CE APPROVAL 600 STAR\/347 VOLT AC 50\/60 HERTZ 250 VOLT DC VOLTAGE RATING 25 KILOAMP AT 600 STAR\/347 VOLT 50 KILOAMP AT 250 VOLT DC INTERRUPTING RATING 15 AMP CURRENT RATING 3 POLE(S) I-LINE CONNECTION LINE LUG LOAD TERMINAL TYPE B FRAME TYPE POWERPACT[TM] BRAND ROHS\/REACH COMPLIANT TRIP SETTING 400 AMP (HOLD) 600 AMP (TRIP) MOUNTING TYPE I-LINE CONTROL TYPE TOGGLE TERMINAL WIRE SIZE 14 TO 2\/0 AWG (COPPER\/ALUMINUM) CONTINUOUS CURRENT RATING 80 PERCENT PHASE CONNECTION TYPE ABC OPERATION AMBIENT AIR TEMPERATURE RATING -13 TO 158 DEG F APPLICATION DISTRIBUTION APPLICABLE STANDARD EAC NOM IEC CCC NEMA AB1 EN\/IEC 60947-2\/60947-5-1 NMX J-266 GB 14048.2 BJ MODEL\u003c\/p\u003e","brand":"Alpha Brokers \u0026 Controls","offers":[{"title":"New","offer_id":48395602362616,"sku":"BJA36015-N","price":1928.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/BJA36015-1_e5bf9fe6-3fe2-4bd5-b700-1cbc56facdaa.webp?v=1788892800"},{"product_id":"bja36020-square-d-20a-3pole-600v-iline-thermal-magnetic-mccb","title":"BJA36020 - Square D - 20A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D BJA36020\u003c\/strong\u003e is a 3-pole, 20-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this BJ-frame breaker provides reliable overload and short-circuit protection for commercial and industrial three-phase branch circuits in 600V electrical distribution systems. Its compact I-Line plug-in design makes it easy to install and replace in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eBJA36020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eBJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for tool-free installation in Square D BJ-frame switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e20-amp, 600V rating for light industrial and commercial three-phase branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for balanced three-phase protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D BJ-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e20A three-phase branch circuit protection in 600V industrial panels\u003c\/li\u003e\n\u003cli\u003eControl equipment and small motor branch circuit protection\u003c\/li\u003e\n\u003cli\u003eManufacturing facility distribution switchboard branch circuits\u003c\/li\u003e\n\u003cli\u003eCommercial building branch circuits at 600V\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Square D BJ-frame I-Line compatible switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D BJA36020?\u003c\/h3\u003e\u003cp\u003eThe BJA36020 is a 20-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB from Square D used for branch circuit protection in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eHow does the BJA36020 differ from the HDA36020?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 20-amp, 3-pole, 600V thermal magnetic I-Line MCCBs, but in different frames: BJA is BJ-frame and HDA is HD-frame. Frame differences affect interrupting ratings, physical size, and switchboard bus compatibility. Always confirm the required frame type before ordering.\u003c\/p\u003e\u003ch3\u003eIs the BJA36020 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D BJA36020. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395602428152,"sku":"BJA36020-N","price":749.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/BJA36030-1_65ade324-5dd2-45b3-8bf8-4fd773a215de.webp?v=1784172755"},{"product_id":"bja36030-square-d-i-line-circuit-breaker-30-amp-3-pole-600-volt","title":"BJA36030 - Square D - PowerPacT B I-Line Molded Case Circuit Breaker - 30 Amp - 3 Pole - 600 Volt","description":"\u003cp\u003e\u003cstrong\u003eThe Square D BJA36030 is a 30A, 3-pole PowerPacT B-Frame molded case circuit breaker with an I-Line plug-in line-side connection, rated 600Y\/347VAC and built for Square D I-Line panelboards and switchboards.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis thermal-magnetic breaker provides fixed Long-Time and Instantaneous (LI) protection with a 65kA interrupting rating at 480VAC and a J-level breaking capacity across its full voltage range. Dual-break rotating contacts limit peak let-through current during a short circuit, and the compact B-Frame body delivers more capacity in roughly two-thirds the footprint of legacy Square D F-Frame breakers — so it drops into existing I-Line mounting spaces during retrofits and panel expansions. Line side is I-Line plug-in with ABC phase sequence; load side ships with mechanical lugs.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePowerPacT B-Frame, I-Line, Type BJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eBJA36030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e30A (125A frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e600Y\/347VAC, 480VAC, 240VAC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAIC Rating\u003c\/th\u003e\n\u003ctd\u003e100kA @ 208Y\/120VAC, 100kA @ 240VAC, 65kA @ 480VAC and 480\/277VAC, 25kA @ 600Y\/347VAC, 50kA @ 250VDC (UL 489)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Style\u003c\/th\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eI-Line jaws on line side, mechanical lugs on load side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase Sequence\u003c\/th\u003e\n\u003ctd\u003eABC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eContinuous Current Rating\u003c\/th\u003e\n\u003ctd\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eSquare D I-Line Panelboards, Switchboards, and Busway Plug-In Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Technology\u003c\/th\u003e\n\u003ctd\u003eThermal Magnetic (LI — Long-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Adjustability\u003c\/th\u003e\n\u003ctd\u003eFixed Thermal \/ Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWire Range\u003c\/th\u003e\n\u003ctd\u003e#14–10 AWG, #8–2\/0 AWG (Al\/Cu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReplaces\u003c\/th\u003e\n\u003ctd\u003eLegacy Square D F-Frame (FA \/ FH) I-Line breakers, per Schneider F-Frame to B-Frame conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL 489, CSA, NOM, IEC 60947-2, CCC, CE marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEndurance\u003c\/th\u003e\n\u003ctd\u003e20,000 mechanical \/ 10,000 electrical cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the interrupting rating of the BJA36030?\u003c\/h3\u003e\n\u003cp\u003e65kA at 480VAC, 100kA at 240VAC, 25kA at 600Y\/347VAC, and 50kA at 250VDC. The \"J\" in the catalog number identifies this 65kA interrupting class.\u003c\/p\u003e\n\u003ch3\u003eWhat does BJA36030 stand for?\u003c\/h3\u003e\n\u003cp\u003eB = PowerPacT B-Frame, J = 65kA interrupting rating at 480VAC, A = I-Line plug-in with ABC phase sequence, 3 = 3 poles, 6 = 600V class, and 030 = 30 amps.\u003c\/p\u003e\n\u003ch3\u003eWhat older Square D breaker does the BJA36030 replace?\u003c\/h3\u003e\n\u003cp\u003eIt is the current replacement for legacy Square D F-Frame I-Line breakers (FA and FH series), which were discontinued. The B-Frame keeps the same I-Line mounting space, so it retrofits into existing I-Line panelboards.\u003c\/p\u003e\n\u003ch3\u003eIs the BJA36030 trip setting adjustable?\u003c\/h3\u003e\n\u003cp\u003eNo. It uses a fixed thermal and fixed magnetic (LI) trip unit, so the 30A rating is not field-adjustable.\u003c\/p\u003e\n\u003ch3\u003eHow does the BJA36030 connect on the line and load sides?\u003c\/h3\u003e\n\u003cp\u003eThe line side uses I-Line jaws that plug directly onto the panelboard bus. The load side is supplied with mechanical lugs accepting #14–10 AWG and #8–2\/0 AWG conductors.\u003c\/p\u003e\n\u003ch3\u003eCan the BJA36030 be used on a 600V system?\u003c\/h3\u003e\n\u003cp\u003eYes, on 600Y\/347VAC wye systems with a 25kA interrupting rating. It is not rated for 600V corner-grounded delta service.\u003c\/p\u003e\n\u003ch3\u003eIs the BJA36030 UL listed?\u003c\/h3\u003e\n\u003cp\u003eYes. It is UL 489 listed and also certified to CSA, NOM, IEC 60947-2, and CCC standards, with CE marking.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395602460920,"sku":"BJA36030-N","price":634.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/BJA36030-1_c54f23b1-5863-47de-8ae8-aa08d80d8895.webp?v=1786488752"},{"product_id":"square-d-ecb34020g3-3-pole-standard-trip-bolt-on-circuit-breakers","title":"ECB34020G3 - Square D - 3 Pole Standard Trip Bolt-On Circuit Breakers","description":"\u003cp\u003eMOLDED CASE TYPE 2.25 INCH W X 2.97 INCH D X 3.5 INCH SIZE POWERLINK LIGHTING CONTROL SYSTEM USED ON 12 TO 8 AWG (ALUMINUM) 10 TO 8 AWG (COPPER) WIRE SIZE UL APPROVAL 240 VAC 480 VAC STAR\/277 VAC VOLTAGE RATING BOLT-ON MOUNTING 65 KILOAMPERE AT 240 VAC 14 KILOAMPERE AT 480 VAC STAR\/277 VAC INTERRUPTING RATING 20 AMPERE CURRENT RATING 3 POLE(S) POWERLINK[TM] BRAND ECB MODEL\u003c\/p\u003e","brand":"Alpha Brokers \u0026 Controls","offers":[{"title":"New","offer_id":48395604590840,"sku":"ECB34020G3-N","price":649.99,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":48395604623608,"sku":"ECB34020G3-U","price":494.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/ECB34020G3-new-1.webp?v=1786043988"},{"product_id":"hda36060u31x-square-d-60a-3pole-600v-iline-solid-state-mccb","title":"HDA36060U31X - Square D - 60A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HDA36060U31X\u003c\/strong\u003e is a 3-pole, 60-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this HD-frame breaker features an adjustable electronic trip unit for precise overcurrent protection in industrial and commercial three-phase 600V branch and feeder circuits. The U31X rating plug provides specific adjustable trip current ranges for selective protection coordination.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHDA36060U31X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolid-state electronic trip unit with adjustable long-time, short-time, and instantaneous protection settings\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D HD-frame switchboards\u003c\/li\u003e\n\u003cli\u003e60A rating for branch and feeder circuit protection in industrial 600V systems\u003c\/li\u003e\n\u003cli\u003e3-pole design for complete three-phase 600V protection\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e60A branch and feeder circuit protection in industrial 600V distribution systems\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection requiring selective coordination\u003c\/li\u003e\n\u003cli\u003eProcess control and manufacturing facility switchboard panels\u003c\/li\u003e\n\u003cli\u003eSystems requiring adjustable electronic trip for coordination studies\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D HD-frame I-Line compatible switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HDA36060U31X?\u003c\/h3\u003e\u003cp\u003eThe HDA36060U31X is a 60-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D (Schneider Electric) used for precise adjustable overcurrent protection of branch and feeder circuits in three-phase 600V industrial electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat does the U31X suffix mean on the HDA36060U31X?\u003c\/h3\u003e\u003cp\u003eThe U31X suffix identifies the electronic trip unit rating plug configuration, which determines the minimum and maximum adjustable current pickup range of the solid-state trip. Consult Schneider Electric documentation to confirm the specific settings for U31X.\u003c\/p\u003e\u003ch3\u003eHow does HDA36060U31X compare to HGA36060U31X?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 60A, 3-pole, 600V I-Line solid-state MCCBs with U31X rating plugs, but in different frame families: HDA is HD-frame and HGA is HG-frame. Frame differences can affect interrupting capacity, accessory options, and switchboard bus compatibility. Verify which frame your equipment requires before ordering.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395606524152,"sku":"HDA36060U31X-N","price":949.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260216_124838-1.jpg?v=1778785378"},{"product_id":"hga36060u31x-square-d-60a-3pole-600v-iline-solid-state-mccb","title":"HGA36060U31X - Square D - 60A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HGA36060U31X\u003c\/strong\u003e is a 3-pole, 60-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this HG-frame breaker features an adjustable electronic trip unit for precise, selective overcurrent protection in industrial and commercial three-phase 600V branch and feeder circuits.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHGA36060U31X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolid-state electronic trip unit with adjustable long-time, short-time, and instantaneous settings\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for quick installation in Square D HG-frame switchboards\u003c\/li\u003e\n\u003cli\u003e60A rating for branch and feeder circuit protection in 600V industrial systems\u003c\/li\u003e\n\u003cli\u003e3-pole design for complete three-phase protection\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e60A branch and feeder circuit protection in industrial 600V switchboards\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection requiring precise trip coordination\u003c\/li\u003e\n\u003cli\u003eProcess plant and manufacturing facility distribution panels\u003c\/li\u003e\n\u003cli\u003eSystems requiring selective coordination with adjustable trip settings\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D HG-frame I-Line compatible switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HGA36060U31X?\u003c\/h3\u003e\u003cp\u003eThe HGA36060U31X is a 60-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D used for precise overcurrent protection of branch and feeder circuits in three-phase 600V industrial and commercial electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat does U31X mean in the HGA36060U31X part number?\u003c\/h3\u003e\u003cp\u003eU31X identifies the rating plug configuration of the solid-state electronic trip unit, determining the adjustable current pickup range available on the breaker. Consult Schneider Electric documentation for the specific settings ranges for the U31X plug.\u003c\/p\u003e\u003ch3\u003eHow does HGA36060U31X differ from HDA36060U31X?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 60A, 3-pole, 600V I-Line solid-state MCCBs with U31X rating plugs. The HGA36060U31X is in the HG frame and the HDA36060U31X is in the HD frame. Frame differences affect interrupting ratings, accessory compatibility, and compatible switchboard bus types.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395607539960,"sku":"HGA36060U31X-N","price":994.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/square-d-hga36060u31x-3-pole-60-amp-600v-circuit-breaker-front-600.jpg?v=1778785406"},{"product_id":"hga36125-square-d-125a-3pole-600v-iline-thermal-magnetic-mccb","title":"HGA36125 - Square D - 125A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HGA36125\u003c\/strong\u003e is a 3-pole, 125-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this HG-frame breaker delivers dependable overcurrent and short-circuit protection for industrial and commercial feeder and main circuits in three-phase 600V distribution systems. The I-Line plug-in design allows for quick, reliable installation in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHGA36125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D HG-frame switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e125A rating for medium-capacity feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D HG-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e125A feeder and branch circuit protection in 600V industrial switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) branch feeder protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial main sub-panel protection at 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing plant distribution panels\u003c\/li\u003e\n\u003cli\u003eReplacement for Square D HG-frame I-Line compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HGA36125?\u003c\/h3\u003e\u003cp\u003eThe HGA36125 is a 125-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB from Square D used for feeder and branch circuit protection in three-phase 600V commercial and industrial electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between HGA36125 and HGA36060U31X?\u003c\/h3\u003e\u003cp\u003eThe HGA36125 is rated at 125A with a fixed thermal magnetic trip, while the HGA36060U31X is rated at 60A with an adjustable solid-state electronic trip unit. Both are Square D HG-frame, 600V I-Line plug-in MCCBs, but they differ in amperage, trip type, and adjustability.\u003c\/p\u003e\u003ch3\u003eIs the HGA36125 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D HGA36125 and ships quickly. Contact us for current availability and pricing.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395607769336,"sku":"HGA36125-N","price":894.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HGA36125-1.webp?v=1789044044"},{"product_id":"square-d-hga36150-3-pole-non-interchangeable-trip-thermal-magnetic-circuit-breakers","title":"HGA36150 - Square D - Molded Case Circuit Breaker I-Line Plug-In - 150 Amp - 3 Pole - 600 Volt","description":"\u003ch2\u003eSquare D HGA36150 – 150 Amp Molded Case Circuit Breaker, I-Line Plug-In\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eSquare D HGA36150\u003c\/strong\u003e is a heavy-duty, 3-pole thermal-magnetic molded case circuit breaker (MCCB) engineered for reliable overcurrent protection in commercial and industrial power distribution systems. Part of the \u003cstrong\u003ePowerPacT H-Frame\u003c\/strong\u003e family, it delivers 150A of continuous protection with fixed long-time and instantaneous (LI) trip functions, and mounts directly into Square D I-Line panelboards and switchboards.\u003c\/p\u003e\u003cp\u003eThe HGA36150 replaces older KA36150 and KH36150 catalog numbers, giving facilities an in-production, HACR-rated upgrade path without panel modifications. With a 35 kAIC interrupting rating at 480VAC, it provides dependable current-limiting performance for demanding branch and feeder circuits.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHGA (PowerPacT H-Frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHGA36150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e208Y\/120VAC, 240VAC, 480Y\/277VAC, 480VAC, 600Y\/347VAC, 600VAC, 250VDC, 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAIC Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e65kA @ 208Y\/120VAC \u0026amp; 240VAC, 35kA @ 480Y\/277VAC \u0026amp; 480VAC, 18kA @ 600Y\/347VAC \u0026amp; 600VAC, 20kA @ 250VDC \u0026amp; 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFor Use With\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D I-Line Panelboards, Switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic (Non-Interchangeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLI – Long-Time, Instantaneous (Fixed Thermal, Fixed Magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG – 3\/0 AWG (Al\/Cu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment, Motor Operator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lugs Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, CSA, HACR, IEC, NOM, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemp Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstruction Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHACR Rated, Current Limiting, Reverse Feed, Visual Trip Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003chr\u003e\u003ch2\u003eWhy Choose the Square D HGA36150?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect I-Line Compatibility:\u003c\/strong\u003e Plugs straight into Square D I-Line panelboards and switchboards — no extra mounting hardware needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal-Magnetic Protection:\u003c\/strong\u003e Fixed long-time and instantaneous trip elements guard against sustained overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHACR Rated \u0026amp; Current Limiting:\u003c\/strong\u003e Suitable for heating, air conditioning, and refrigeration branch circuits with demanding fault currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-In Replacement:\u003c\/strong\u003e Cross-references KA36150 and KH36150 for fast, compatible upgrades.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCommercial and industrial power distribution panels\u003c\/li\u003e\n\u003cli\u003eHVAC and mechanical equipment feeders\u003c\/li\u003e\n\u003cli\u003eManufacturing and process control systems\u003c\/li\u003e\n\u003cli\u003eSwitchboard and panelboard retrofits\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat panels is the HGA36150 compatible with?\u003c\/strong\u003e\u003cbr\u003eIt's built for Square D I-Line style panelboards and switchboards that accept plug-in breakers — no additional mounting hardware is required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the interrupting rating of the HGA36150?\u003c\/strong\u003e\u003cbr\u003e35 kA at 480Y\/277VAC and 480VAC, 65 kA at 208Y\/120VAC and 240VAC, and 18 kA at 600VAC — see the specifications table for the full voltage breakdown.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the HGA36150 use a fixed or adjustable trip?\u003c\/strong\u003e\u003cbr\u003eIt uses a fixed thermal-magnetic (non-interchangeable) trip with LI (long-time, instantaneous) function.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat does the HGA36150 replace?\u003c\/strong\u003e\u003cbr\u003eIt's a direct upgrade path for the discontinued KA36150 and KH36150 breakers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this a new unit?\u003c\/strong\u003e\u003cbr\u003eYes — this listing (SKU HGA36150-N) is new-in-box and ready for immediate installation.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395607834872,"sku":"HGA36150-N","price":994.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HGA36150-1.webp?v=1789044621"},{"product_id":"hja36060-square-d-60a-3pole-600v-iline-thermal-magnetic-mccb","title":"HJA36060 - Square D - 60A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HJA36060\u003c\/strong\u003e is a 3-pole, 60-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this HJ-frame breaker provides reliable overload and short-circuit protection for commercial and industrial three-phase branch and feeder circuits. The I-Line plug-in interface allows fast, tool-free installation in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHJA36060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for tool-free installation in Square D HJ-frame I-Line equipment\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for accurate overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e60-amp rating for industrial and commercial branch and feeder circuit applications\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D HJ-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e60A branch circuit protection in 600V three-phase industrial panels\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit and feeder protection in switchboards\u003c\/li\u003e\n\u003cli\u003eHVAC and process equipment branch circuits at 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility distribution panels\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Square D HJ-frame I-Line compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HJA36060?\u003c\/h3\u003e\u003cp\u003eThe HJA36060 is a 60-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB from Square D used to protect three-phase branch and feeder circuits in industrial and commercial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between HJA36060 and HGA36060U31X?\u003c\/h3\u003e\u003cp\u003eThe HJA36060 is a thermal magnetic MCCB in the HJ frame, while the HGA36060U31X is a solid-state electronic trip MCCB in the HG frame with an adjustable rating plug. The HGA36060U31X offers adjustable trip settings for selective coordination; the HJA36060 provides fixed thermal magnetic protection.\u003c\/p\u003e\u003ch3\u003eIs the HJA36060 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D HJA36060 and offers fast shipping. Contact us for current availability and pricing.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395608555768,"sku":"HJA36060-N","price":594.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HJA36060-1.jpg?v=1778785430"},{"product_id":"square-d-hla36150-3-pole-non-interchangeable-trip-thermal-magnetic-circuit-breakers","title":"HLA36150 - Square D - Molded Case Circuit Breaker I-Line Plug-In - 150 Amp - 3 Pole - 600 Volt","description":"\u003ch2\u003eSquare D HLA36150 – 150 Amp Molded Case Circuit Breaker, I-Line Plug-In\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eSquare D HLA36150\u003c\/strong\u003e is a heavy-duty, 3-pole thermal-magnetic molded case circuit breaker built for commercial and industrial power distribution. Part of the \u003cstrong\u003ePowerPacT H-Frame\u003c\/strong\u003e family, it delivers 150A of continuous protection and mounts directly into Square D I-Line panelboards and switchboards via a plug-on phase connection.\u003c\/p\u003e\u003cp\u003eRated at 100 kAIC at 480VAC, the HLA36150 uses a dual-break rotary contact structure that reduces peak current during short-circuit faults, giving it exceptional current-limiting performance for demanding electrical systems.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHLA (PowerPacT H-Frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHLA36150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC, 480VAC, 600VAC, 250VDC, 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAIC Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e125kA @ 240VAC, 100kA @ 480VAC, 50kA @ 600VAC, 20kA @ 250VDC, 50kA @ 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFor Use With\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D I-Line Panelboards, Switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic (Non-Interchangeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLI – Long-Time, Instantaneous (Fixed Thermal, Adjustable Magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG – 3\/0 AWG (Al\/Cu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle, Lug Kits, Terminal Shields\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lugs Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, CSA, IEC, NOM, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemp Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstruction Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Limiting, HACR Rated, Reverse Feed, Non-Interchangeable Trip, 80% Rated, Dual-Break Rotary Contact Structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003chr\u003e\u003ch2\u003eWhy Choose the Square D HLA36150?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Interrupting Capacity:\u003c\/strong\u003e 100 kAIC at 480VAC for demanding fault-current environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Break Rotary Contacts:\u003c\/strong\u003e Reduces peak let-through current during short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect I-Line Compatibility:\u003c\/strong\u003e Plugs straight into Square D I-Line panelboards and switchboards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e80% Rated, HACR Rated:\u003c\/strong\u003e Suited to continuous commercial and HVAC loads.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCommercial and industrial power distribution panels\u003c\/li\u003e\n\u003cli\u003eHVAC and mechanical equipment feeders\u003c\/li\u003e\n\u003cli\u003eManufacturing and process control systems\u003c\/li\u003e\n\u003cli\u003eSwitchboard and panelboard retrofits\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat panels is the HLA36150 compatible with?\u003c\/strong\u003e\u003cbr\u003eSquare D I-Line style panelboards and switchboards that accept plug-in breakers — no additional mounting hardware required.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the interrupting rating of the HLA36150?\u003c\/strong\u003e\u003cbr\u003e100 kA at 480VAC, 125 kA at 240VAC, and 50 kA at 600VAC and 500VDC — see the specifications table for the full breakdown.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the trip unit fixed or adjustable?\u003c\/strong\u003e\u003cbr\u003eIt's a thermal-magnetic breaker with fixed thermal and adjustable magnetic settings, non-interchangeable trip.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat accessories are available?\u003c\/strong\u003e\u003cbr\u003eShunt trip, auxiliary switch, undervoltage release, alarm switch, padlock attachment, motor operator, rotary handle, lug kits, and terminal shields.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this a new unit?\u003c\/strong\u003e\u003cbr\u003eYes — this listing (SKU HLA36150-N) is new-in-box and ready for immediate installation.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395609407736,"sku":"HLA36150-N","price":2184.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HLA-FR_8bd0d77f-7a08-4aae-8d92-de5793d03cd0.webp?v=1789048758"},{"product_id":"jja36200-square-d-200a-3pole-600v-iline-thermal-magnetic-mccb","title":"JJA36200 - Square D - 200A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36200\u003c\/strong\u003e is a 3-pole, 200-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this JJ-frame breaker provides dependable overload and short-circuit protection for industrial feeder and main circuits in three-phase 600V power distribution systems. Its I-Line plug-in interface makes installation and replacement fast and straightforward in compatible Square D switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJJA36200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D JJ-frame switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e200A rating for medium-to-large industrial feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D JJ-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e200A feeder and sub-main protection in 600V three-phase switchboards\u003c\/li\u003e\n\u003cli\u003eIndustrial motor control center (MCC) feeder circuit protection\u003c\/li\u003e\n\u003cli\u003eManufacturing and process plant distribution systems\u003c\/li\u003e\n\u003cli\u003eCommercial facility main and sub-main circuit protection\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Square D JJ-frame I-Line equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D JJA36200?\u003c\/h3\u003e\u003cp\u003eThe Square D JJA36200 is a 200-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB used for feeder and main circuit protection in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between JJA36200 and JJA36250?\u003c\/h3\u003e\u003cp\u003eThe JJA36200 is rated at 200A while the JJA36250 is rated at 250A. Both are Square D JJ-frame, 600V, 3-pole, thermal magnetic I-Line plug-in MCCBs. Select based on your calculated load and NEC requirements.\u003c\/p\u003e\u003ch3\u003eIs the JJA36200 compatible with Square D I-Line switchboards?\u003c\/h3\u003e\u003cp\u003eYes. The JJA36200 uses I-Line plug-in mounting and is compatible with Square D switchboards and panelboards designed for JJ-frame breakers. Verify bus rating and frame compatibility before installation.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395611013368,"sku":"JJA36200-N","price":1299.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/JJA36200-New-1_00f769cb-5ef0-404d-8347-994d10564bbb-1.jpg?v=1778785481"},{"product_id":"jja36250-square-d-250a-3pole-600v-iline-thermal-magnetic-mccb","title":"JJA36250 - Square D - 250A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36250\u003c\/strong\u003e is a 3-pole, 250-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this JJ-frame breaker delivers dependable overload and short-circuit protection for large industrial feeder and main circuits in three-phase 600V power distribution systems. The I-Line plug-in interface enables fast, reliable installation in compatible Square D switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJJA36250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for quick installation in Square D JJ-frame compatible switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e250A rating for large industrial feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D JJ-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e250A feeder and sub-main circuit protection in industrial 600V switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) feeder circuit breakers\u003c\/li\u003e\n\u003cli\u003eHeavy manufacturing and process plant distribution panels\u003c\/li\u003e\n\u003cli\u003eCommercial building main and sub-main protection\u003c\/li\u003e\n\u003cli\u003eIndustrial three-phase 600V power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D JJA36250?\u003c\/h3\u003e\u003cp\u003eThe Square D JJA36250 is a 250-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB used for overcurrent and short-circuit protection of feeder and main circuits in three-phase 600V industrial and commercial electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between JJA36250 and JJA36250U31X or JJA36250U33X?\u003c\/h3\u003e\u003cp\u003eThe JJA36250 uses a fixed thermal magnetic trip unit, while the U31X, U33X, and U44X variants use an adjustable solid-state electronic trip unit. The solid-state versions offer adjustable settings for selective coordination; the thermal magnetic version provides fixed, straightforward protection at a lower cost.\u003c\/p\u003e\u003ch3\u003eIs the JJA36250 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D JJA36250 in new condition and ships quickly. Contact us to confirm current availability and lead time.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395611046136,"sku":"JJA36250-N","price":1399.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/JJA36250-New-1_e02139e4-b5f9-4658-863c-b01e55e2b45e.jpg?v=1778785483"},{"product_id":"jja36250u31x-square-d-250a-3pole-600v-iline-solid-state-mccb","title":"JJA36250U31X - Square D - 250A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36250U31X\u003c\/strong\u003e is a 3-pole, 250-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this JJ-frame breaker features an adjustable electronic trip unit for precise overcurrent protection of large industrial feeder and main circuits in three-phase 600V systems.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJJA36250U31X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable solid-state trip unit with long-time, short-time, and instantaneous settings for selective coordination\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D JJ-frame compatible switchboards\u003c\/li\u003e\n\u003cli\u003e250A rating for large industrial feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V protection\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial feeder and sub-main protection in 600V switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) main incoming protection\u003c\/li\u003e\n\u003cli\u003eHeavy manufacturing and process facility power distribution\u003c\/li\u003e\n\u003cli\u003eSystems requiring selective coordination with adjustable trip settings\u003c\/li\u003e\n\u003cli\u003eData center and critical infrastructure 600V feeder circuits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D JJA36250U31X?\u003c\/h3\u003e\u003cp\u003eThe JJA36250U31X is a 250-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D used to protect large feeder and main circuits in three-phase 600V industrial and commercial electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does U31X mean in the JJA36250U31X part number?\u003c\/h3\u003e\u003cp\u003eThe U31X suffix identifies the rating plug configuration of the solid-state electronic trip unit, which sets the adjustable current pickup range. This differs from U33X and U44X variants. Consult Schneider Electric documentation to confirm the correct plug for your coordination study.\u003c\/p\u003e\u003ch3\u003eHow does the JJA36250U31X differ from JJA36250U33X or JJA36250U44X?\u003c\/h3\u003e\u003cp\u003eAll three are Square D 250A, 3-pole, 600V I-Line solid-state JJ-frame MCCBs. The U31X, U33X, and U44X suffixes indicate different rating plug configurations that affect the adjustable trip current range of the electronic trip unit. Select the correct suffix based on your protection coordination requirements.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395611078904,"sku":"JJA36250U31X-N","price":2199.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/shopping-2-1-scaled.jpg?v=1778785485"},{"product_id":"jja36250u43x-square-d-250a-3-pole-600v-iline-solid-state-mccb","title":"JJA36250U43X - Square D - 250A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36250U43X\u003c\/strong\u003e is a 3-pole, 250-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this JJ-frame electronic trip breaker delivers adjustable, highly accurate overcurrent protection for large industrial feeder circuits and main distribution applications. Available in new and used (reconditioned) condition, it is a high-performance solution for three-phase 600V systems requiring selective coordination.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJJA36250U43X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolid-state electronic trip unit with adjustable long-time, short-time, and instantaneous settings\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for quick installation in Square D JJ-frame compatible switchboards\u003c\/li\u003e\n\u003cli\u003e250-amp rating for large feeder and sub-main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600V industrial power systems\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V for demanding environments\u003c\/li\u003e\n\u003cli\u003eAvailable new and reconditioned — all units tested prior to shipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e250A feeder and main circuit protection in industrial 600V switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) main incoming feeds\u003c\/li\u003e\n\u003cli\u003eSub-main protection in large industrial and commercial facilities\u003c\/li\u003e\n\u003cli\u003eProcess plant and manufacturing facility power distribution\u003c\/li\u003e\n\u003cli\u003eSelective coordination systems requiring adjustable trip settings\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D JJA36250U43X?\u003c\/h3\u003e\u003cp\u003eThe JJA36250U43X is a 250-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D (Schneider Electric). It is used for main and feeder overcurrent protection in three-phase industrial and commercial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between JJA36250U43X and JJA36250U44X?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 250A, 3-pole, 600V I-Line solid-state MCCBs in the JJ frame. The U43X and U44X suffixes indicate different rating plug configurations for the electronic trip unit, which affects the adjustable current pickup range. Consult Schneider Electric to confirm which plug is correct for your system coordination study.\u003c\/p\u003e\u003ch3\u003eIs the JJA36250U43X available in used condition?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the JJA36250U43X in both new and used (reconditioned) condition. All used breakers are inspected and tested before shipping to ensure reliable operation.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395611111672,"sku":"JJA36250U43X-N","price":3499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/CB-JJA36250U43X-1.jpg?v=1778785486"},{"product_id":"lja36400u43x-square-d-400a-3-pole-600v-iline-solid-state-mccb","title":"LJA36400U43X - Square D - 400A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D LJA36400U43X\u003c\/strong\u003e is a 3-pole, 400-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this LJ-frame breaker features an adjustable electronic solid-state trip unit for precise, selective overcurrent protection in high-capacity industrial feeder and main circuit applications. It combines high interrupting capacity with flexible trip settings for demanding three-phase 600V power systems.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLJA36400U43X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eLJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable solid-state trip unit with long-time, short-time, and instantaneous settings for selective coordination\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D LJ-frame I-Line switchboards\u003c\/li\u003e\n\u003cli\u003e400-amp capacity for heavy industrial main and feeder circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V protection\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e400A main and feeder breaker in heavy industrial I-Line switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) main incoming protection\u003c\/li\u003e\n\u003cli\u003eLarge manufacturing plant main distribution panels\u003c\/li\u003e\n\u003cli\u003eProcess plant and refinery electrical distribution systems\u003c\/li\u003e\n\u003cli\u003eHigh fault-current industrial environments requiring 65kA interrupting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D LJA36400U43X?\u003c\/h3\u003e\u003cp\u003eThe LJA36400U43X is a 400-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D used for main and feeder circuit protection in heavy industrial three-phase 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does U43X mean in the LJA36400U43X part number?\u003c\/h3\u003e\u003cp\u003eThe U43X suffix on Square D solid-state MCCBs identifies the rating plug configuration of the electronic trip unit, which determines the adjustable current range (pickup and delay settings) available on the breaker. Consult Schneider Electric documentation for the specific ranges associated with U43X.\u003c\/p\u003e\u003ch3\u003eIs the LJA36400U43X available as new and used?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D LJA36400U43X in new condition. Contact us for current pricing and availability.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395611832568,"sku":"LJA36400U43X-N","price":4499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/EfSZpneA-LJA36400U33X_Illustration_Front.jpg?v=1778785499"},{"product_id":"la36400-square-d-400a-3-pole-600v-iline-mccb","title":"LA36400 - Square D - 400A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D LA36400\u003c\/strong\u003e is a 3-pole, 400-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, the LA-frame breaker delivers high-capacity overcurrent and short-circuit protection for large industrial feeder and main circuits. The I-Line plug-in interface allows for fast installation and replacement in compatible Square D switchboards and panelboards, making it a standard choice for heavy industrial power distribution.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLA36400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e30kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eLA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in design for quick installation and removal in Square D I-Line switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e400-amp capacity for high-current main and feeder circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600VAC industrial distribution systems\u003c\/li\u003e\n\u003cli\u003eLA frame standard in Square D I-Line switchboard applications\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e400A main or feeder breaker in industrial I-Line switchboards\u003c\/li\u003e\n\u003cli\u003eLarge motor control center (MCC) incoming feeder protection\u003c\/li\u003e\n\u003cli\u003eHeavy manufacturing plant distribution panels\u003c\/li\u003e\n\u003cli\u003eIndustrial sub-main circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eUtility and process industry high-capacity power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D LA36400?\u003c\/h3\u003e\u003cp\u003eThe Square D LA36400 is a 400-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB used as a main or feeder circuit breaker in heavy industrial and commercial three-phase 600VAC switchboards and panelboards.\u003c\/p\u003e\u003ch3\u003eWhat is the interrupting rating of the LA36400?\u003c\/h3\u003e\u003cp\u003eThe Square D LA36400 has a standard interrupting capacity of 30kA at 480V. This is suitable for most industrial distribution systems; for higher available fault current environments, consider the LJA36400U43X with a solid-state trip and higher interrupting rating.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between LA36400 and LJA36400U43X?\u003c\/h3\u003e\u003cp\u003eThe LA36400 uses a thermal magnetic trip unit (fixed settings), while the LJA36400U43X uses an adjustable solid-state electronic trip unit, offering higher interrupting capacity and flexible protection coordination. The LJA is preferred for systems requiring selective coordination or higher fault-current protection.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395624939768,"sku":"LA36400-N","price":1019.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260302_154526.jpg?v=1778785708"},{"product_id":"pdg23m0050tffj-eaton-50a-3-pole-600v-feed-thru-mccb","title":"PDG23M0050TFFJ - Eaton - 50A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton PDG23M0050TFFJ\u003c\/strong\u003e is a 3-pole, 50-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by Eaton, this PDG-frame breaker delivers dependable overcurrent and short-circuit protection for commercial and industrial three-phase branch and feeder circuits at 600V. The feed-through mounting makes it suitable for use in service entrance and main distribution panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003ePDG23M0050TFFJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003ePDG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main and branch circuit applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e50-amp rating for light industrial and commercial branch and feeder circuits at 600V\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase power system protection\u003c\/li\u003e\n\u003cli\u003eRobust Eaton PDG frame construction for industrial environments\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e50A three-phase branch circuit protection in 600V industrial panels\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection in commercial and industrial applications\u003c\/li\u003e\n\u003cli\u003eHVAC and process equipment feeder circuits at 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing plant branch circuit distribution\u003c\/li\u003e\n\u003cli\u003eFeed-through sub-panel main protection in 600VAC systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton PDG23M0050TFFJ?\u003c\/h3\u003e\u003cp\u003eThe Eaton PDG23M0050TFFJ is a 50-amp, 3-pole, 600V thermal magnetic feed-through MCCB used to protect three-phase branch and feeder circuits in industrial and commercial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eIs the PDG23M0050TFFJ available in feed-thru only, or other mounting styles?\u003c\/h3\u003e\u003cp\u003eThe PDG23M0050TFFJ is specifically configured for feed-through (feed-thru) mounting. Eaton offers other PDG series models with different mounting configurations. Check the full PDG series catalog or contact Alpha Brokers \u0026amp; Controls for alternatives.\u003c\/p\u003e\u003ch3\u003eWhat is the interrupting capacity of the PDG23M0050TFFJ?\u003c\/h3\u003e\u003cp\u003eThe PDG23M0050TFFJ carries an interrupting rating of 65kA at 240V and 25kA at 600V, making it suitable for the majority of commercial and industrial 600V power systems.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395627823352,"sku":"PDG23M0050TFFJ-N","price":534.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/PDG23M0050TFFJ-All-New-1_664ebb18-55c3-4f45-9104-cfe3132a24a9.jpg?v=1778785760"},{"product_id":"pdg23m0125tffj-eaton-125a-3-pole-600v-feed-thru-mccb","title":"PDG23M0125TFFJ - Eaton - 125A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton PDG23M0125TFFJ\u003c\/strong\u003e is a 3-pole, 125-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by Eaton, this PDG-frame breaker provides reliable overcurrent and short-circuit protection for commercial and industrial three-phase feeder and main circuits. Its feed-through configuration makes it well-suited for panelboard main breaker and service entrance applications at 600V.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003ePDG23M0125TFFJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003ePDG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main breaker and service entrance applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip mechanism for accurate overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e125-amp rating for main and feeder circuit applications in 600V systems\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase power protection\u003c\/li\u003e\n\u003cli\u003eHeavy-duty PDG frame construction for industrial reliability\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e125A main circuit breaker in industrial and commercial 600V panelboards\u003c\/li\u003e\n\u003cli\u003eService entrance protection for three-phase 600VAC systems\u003c\/li\u003e\n\u003cli\u003eFeeder circuit protection in manufacturing and process facilities\u003c\/li\u003e\n\u003cli\u003eSub-panel main protection in large commercial buildings\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Eaton PDG-frame compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton PDG23M0125TFFJ?\u003c\/h3\u003e\u003cp\u003eThe Eaton PDG23M0125TFFJ is a 125-amp, 3-pole, 600V thermal magnetic feed-through MCCB used to protect main and feeder circuits in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eCan the PDG23M0125TFFJ be used as a service entrance breaker?\u003c\/h3\u003e\u003cp\u003eYes. The feed-through mounting and 125A, 600V rating make the PDG23M0125TFFJ suitable for service entrance and main distribution board applications. Verify compliance with local codes and NEC requirements for your specific installation.\u003c\/p\u003e\u003ch3\u003eHow does the PDG23M0125TFFJ compare to PDG23M0200TFFJ?\u003c\/h3\u003e\u003cp\u003eBoth are Eaton PDG-frame, 600V, 3-pole, thermal magnetic feed-through MCCBs. The PDG23M0125TFFJ is rated at 125A, while the PDG23M0200TFFJ is rated at 200A. Choose based on your calculated load requirements per NEC.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395627856120,"sku":"PDG23M0125TFFJ-N","price":984.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/jVsx01vX-PDG23M0125TFFJ-New-1_a3910adb-c193-40ad-bfad-a76901783986_jpg.webp?v=1778785762"},{"product_id":"pdg23m0200tffj-eaton-200a-3-pole-600v-feed-thru-mccb","title":"PDG23M0200TFFJ - Eaton - 200A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton PDG23M0200TFFJ\u003c\/strong\u003e is a 3-pole, 200-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by Eaton, this PDG-frame breaker delivers reliable overcurrent and fault protection for main and feeder circuits in industrial and commercial three-phase power distribution systems. The feed-through design is ideal for service entrance and main distribution board configurations.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003ePDG23M0200TFFJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003ePDG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main breaker and service entrance panelboard applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e200-amp rating for medium-to-large main and feeder circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V system protection\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade PDG frame with robust construction\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, fully NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e200A main circuit breaker in industrial and commercial 600V panelboards\u003c\/li\u003e\n\u003cli\u003eService entrance protection for three-phase systems\u003c\/li\u003e\n\u003cli\u003eFeeder circuit protection in manufacturing facilities\u003c\/li\u003e\n\u003cli\u003eSub-main breaker in large-scale commercial electrical distribution\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Eaton PDG-compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton PDG23M0200TFFJ?\u003c\/h3\u003e\u003cp\u003eThe Eaton PDG23M0200TFFJ is a 200-amp, 3-pole, 600V thermal magnetic feed-through MCCB used as a main or feeder circuit breaker in three-phase industrial and commercial 600V electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between PDG23M0200TFFJ and PDG23M0225TFFJ?\u003c\/h3\u003e\u003cp\u003eThe primary difference is the amperage rating: the PDG23M0200TFFJ is rated at 200A, while the PDG23M0225TFFJ is rated at 225A. Both share the same PDG frame, 600V rating, feed-through mount, and thermal magnetic trip type. Select based on your circuit's load requirements and NEC calculations.\u003c\/p\u003e\u003ch3\u003eIs the PDG23M0200TFFJ in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Eaton PDG23M0200TFFJ and ships quickly. Contact us to confirm current availability.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395627921656,"sku":"PDG23M0200TFFJ-N","price":945.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/PDG23M0200TFFJ-All-New-1_43235bad-2f05-47f4-8a53-b3abe02ad193.jpg?v=1778785763"},{"product_id":"pdg23m0225tffj-eaton-225a-3-pole-600v-bolt-on-mccb","title":"PDG23M0225TFFJ - Eaton - 225A 3-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton PDG23M0225TFFJ\u003c\/strong\u003e is a 3-pole, 225-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. Manufactured by Eaton, the PDG series is designed for reliable main and feeder circuit protection in industrial and commercial three-phase 600V power distribution systems. The bolt-on configuration ensures secure mechanical attachment and consistent contact pressure in panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003ePDG23M0225TFFJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e225A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003ePDG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure, vibration-resistant installation in compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable time-delay overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e225-amp capacity for main circuit and large feeder protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V power systems\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade PDG frame construction\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e225A main circuit breaker in commercial and industrial panelboards\u003c\/li\u003e\n\u003cli\u003eFeeder circuit protection in 600V three-phase systems\u003c\/li\u003e\n\u003cli\u003eManufacturing plant distribution panel main breaker\u003c\/li\u003e\n\u003cli\u003eIndustrial switchboard branch circuit protection\u003c\/li\u003e\n\u003cli\u003eSub-main breaker in large commercial electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton PDG23M0225TFFJ?\u003c\/h3\u003e\u003cp\u003eThe Eaton PDG23M0225TFFJ is a 225-amp, 3-pole, 600V thermal magnetic bolt-on MCCB used as a main or feeder circuit breaker in three-phase industrial and commercial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does TFFJ mean in the Eaton PDG23M0225TFFJ part number?\u003c\/h3\u003e\u003cp\u003eIn Eaton PDG series part numbers, the suffix characters indicate options such as trip rating, frame size, and terminal\/lug configuration. TFFJ identifies specific factory-configured trip and accessory options. Consult Eaton product documentation for the full breakdown of suffix meanings for this model.\u003c\/p\u003e\u003ch3\u003eIs the PDG23M0225TFFJ compatible with Eaton panelboards?\u003c\/h3\u003e\u003cp\u003eYes. The PDG23M0225TFFJ is designed for bolt-on installation in Eaton and compatible third-party panelboards that accept PDG-frame MCCBs. Verify bus rating and mounting compatibility before installation.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395627987192,"sku":"PDG23M0225TFFJ-N","price":945.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/PDG23M0225TFFJ-All-New-1_7845656f-7504-4f6f-af09-ba5c394958cc.jpg?v=1778785765"},{"product_id":"ted134020-ge-20a-3pole-480v-feed-thru-mccb","title":"TED134020 - GE - 20A 3-Pole 480V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eGE TED134020\u003c\/strong\u003e is a 3-pole, 20-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC with feed-through (feed-thru) mounting. Manufactured by General Electric (now ABB), the TED1 series delivers reliable overload and short-circuit protection for commercial and light industrial three-phase 480V branch and feeder circuits. Its feed-through configuration is suitable for main and branch breaker applications in compatible GE panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eTED134020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE \/ ABB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eTED1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main and branch circuit applications in GE-compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e20-amp, 480V rating for light commercial and industrial three-phase branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole design for balanced three-phase 480V circuit protection\u003c\/li\u003e\n\u003cli\u003eCompact TED1 frame for GE and compatible switchgear\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e20A three-phase branch circuit protection in 480V distribution panels\u003c\/li\u003e\n\u003cli\u003eSmall motor and equipment branch circuit protection\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial feeder circuits at 480V\u003c\/li\u003e\n\u003cli\u003eControl panel branch circuit protection\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in GE\/ABB TED1-compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the GE TED134020?\u003c\/h3\u003e\u003cp\u003eThe GE TED134020 is a 20-amp, 3-pole, 480V thermal magnetic feed-through MCCB used for branch circuit and feeder protection in three-phase commercial and light industrial 480V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eIs the TED134020 the same as TED134020WL?\u003c\/h3\u003e\u003cp\u003eThe TED134020WL adds a factory-installed wire lug (WL suffix) for simplified wiring connections. Both are electrically identical — the only difference is the included terminal hardware.\u003c\/p\u003e\u003ch3\u003eWhat panelboards are compatible with the GE TED134020?\u003c\/h3\u003e\u003cp\u003eThe TED134020 is designed for GE and ABB TED1-frame compatible panelboards. Always verify frame compatibility and bus rating before installation.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395651449080,"sku":"TED134020-N","price":414.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260203_153410_897af32f-a3c3-4389-bd7d-446b84e1e42a.jpg?v=1778786135"},{"product_id":"ted134100-ge-molded-case-circuit-breaker-feed-thru-100-amp-3-pole-480-volt","title":"TED134100 - GE - Molded Case Circuit Breaker Feed-Thru - 100 Amp - 3 Pole - 480 Volt","description":"\u003cdiv id=\"tabb5a7adde1af5c87d7fd797b6245c2a39\" class=\"tab-content--body\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv class=\"tab-content--body\" id=\"tabb5a7adde1af5c87d7fd797b6245c2a39\"\u003e\n\u003cdiv class=\"tab-content--heading-text\"\u003eDescription\u003c\/div\u003e\nBuilt to handle demanding electrical loads, the GE TED134100 is a 3-pole, 100A molded case circuit breaker. It provides reliable long-time and instantaneous protection with an 18kAIC rating at 480VAC. This bolt-on MCCB is specifically designed to integrate with GE A-Series panelboards and Spectra Series switchboards. It is HACR rated and supports reverse feed configurations. For modern upgrades, this legacy E-frame model is officially replaced by the newer TEYD3100B.\u003c\/div\u003e\n\u003cdiv class=\"tab-content--body\" id=\"tab17989744c0ba77bb014035ff2d0a5e50\"\u003e\n\u003cdiv class=\"tab-content--heading-text\"\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"md-flex jsProductUpdate jsProductReplace\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTED134100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC, 480VAC, 600VAC, 250VDC, 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAIC Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFor Use With\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eGE A-Series Panelboards, Spectra Series Switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Adjustability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Thermal, Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AWG - 3\/0 AWG (Cu), 1 AWG - 3\/0 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMin Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AWG (Cu), 1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lugs (TCAL15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 5.1, HACR, UL 489, NEMA AB 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, CSA, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemp Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e40C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstruction Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make\/Quick-Break, Trip-Free Mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395651907832,"sku":"TED134100-N","price":479.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/TED134100_2_78ef8c6e-6c0e-48f7-af47-fa39ba17b80a.webp?v=1778786144"},{"product_id":"ted136030-ge-molded-case-circuit-breaker-feed-thru-30-amp-3-pole-600-volt","title":"TED136030 - GE - E150 Bolt-On Molded Case Circuit Breaker - 30 Amp - 3 Pole - 600 Volt","description":"\u003cp\u003e\u003cstrong\u003eThe GE TED136030 is a 30A, 3-pole E150-frame molded case circuit breaker with bolt-on mounting, rated 600VAC and built for GE A-Series and Spectra Series panelboards and switchboards.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThirty amps at 600 volts covers most small three-phase motor feeders, transformer primaries, and equipment disconnect circuits in commercial buildings. The TED136030 delivers fixed thermal-magnetic Long-Time and Instantaneous (LI) protection with an 18kA interrupting rating at 480VAC and 14kA at 600VAC. Quick-make\/quick-break contacts and a trip-free mechanism ensure the breaker opens on a fault even if the handle is held closed, and common trip links all three poles so a single-phase fault de-energizes the whole circuit. TCAL12 load lugs are included, and the unit is HACR and HID rated for HVAC and discharge lighting duty.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGE \/ ABB (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eE150 Line, Type TED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eTED136030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e30A (150A frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e600VAC, 480VAC, 240VAC, 500VDC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAIC Rating\u003c\/th\u003e\n\u003ctd\u003e18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC (UL 489)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Style\u003c\/th\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eGE A-Series Panelboards, GE Spectra Series Panelboards, Switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Technology\u003c\/th\u003e\n\u003ctd\u003eThermal Magnetic (LI — Long-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Adjustability\u003c\/th\u003e\n\u003ctd\u003eFixed Thermal \/ Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWire Range\u003c\/th\u003e\n\u003ctd\u003e#14–3 AWG (Cu), #12–1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccessories Included\u003c\/th\u003e\n\u003ctd\u003eTCAL12 Load Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable Options\u003c\/th\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL 489, CSA C22.2 No. 5, NEMA AB 1, HACR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConstruction Features\u003c\/th\u003e\n\u003ctd\u003eHACR Rated, HID Rated, Common Trip, Quick-Make\/Quick-Break, Trip-Free Mechanism, Reverse Feed Capable, Non-Interchangeable Trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Dimensions\u003c\/th\u003e\n\u003ctd\u003e10 x 8 x 8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Weight\u003c\/th\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the difference between the TED136030 and the TED136030WL?\u003c\/h3\u003e\n\u003cp\u003eThe WL suffix designates a factory catalog number that ships with wire lugs installed. Electrically and mechanically the breakers are identical; both units listed here include TCAL12 lugs.\u003c\/p\u003e\n\u003ch3\u003eWhat is the interrupting rating of the TED136030?\u003c\/h3\u003e\n\u003cp\u003e18kA at 240VAC and 480VAC, 14kA at 600VAC, and 10kA at 250VDC and 500VDC.\u003c\/p\u003e\n\u003ch3\u003eHow does the TED differ from the THED?\u003c\/h3\u003e\n\u003cp\u003eThe THED is the high-interrupting version of the same E150 frame, rated 25kA at 480VAC and 65kA at 240VAC versus the TED's 18kA. Choose based on the available fault current at the panel.\u003c\/p\u003e\n\u003ch3\u003eWhat does trip-free mean?\u003c\/h3\u003e\n\u003cp\u003eThe mechanism will open the contacts on an overcurrent even if the operating handle is held in the ON position, so the breaker cannot be defeated manually.\u003c\/p\u003e\n\u003ch3\u003eWhat panelboards accept the TED136030?\u003c\/h3\u003e\n\u003cp\u003eGE A-Series and Spectra Series panelboards and switchboards using bolt-on mounting hardware.\u003c\/p\u003e\n\u003ch3\u003eCan the TED136030 be reverse fed?\u003c\/h3\u003e\n\u003cp\u003eYes. Reverse feed is permitted with no line\/load marking restriction under UL 489.\u003c\/p\u003e\n\u003ch3\u003eIs the 30A trip rating adjustable?\u003c\/h3\u003e\n\u003cp\u003eNo. The trip unit is fixed and non-interchangeable.\u003c\/p\u003e\n\u003ch3\u003eIs the TED136030 UL listed?\u003c\/h3\u003e\n\u003cp\u003eYes. It is UL 489 listed and CSA certified to C22.2 No. 5, and it is HACR rated.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395652038904,"sku":"TED136030-N","price":399.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/TED136030-GE-MoldedCaseCircuitBreakerFeed-Thru-30Amp-3Pole-600Volt.webp?v=1786726718"},{"product_id":"ted136050-ge-molded-case-circuit-breaker-feed-thru-50-amp-3-pole-600-volt","title":"TED136050 - GE - E150 Bolt-On Molded Case Circuit Breaker - 50 Amp - 3 Pole - 600 Volt","description":"\u003cp\u003e\u003cstrong\u003eThe GE TED136050 is a 50A, 3-pole E150-frame molded case circuit breaker with bolt-on mounting, rated 600VAC and built for GE A-Series and Spectra panelboards, switchboards, motor control centers, and E150 enclosures.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFifty amps at 600 volts is one of the most-specified sizes in commercial and light industrial distribution — rooftop units, pump panels, and small transformer primaries all land in this range. The TED136050 delivers fixed thermal-magnetic Long-Time and Instantaneous (LI) protection with an 18kA interrupting rating at 480VAC and 14kA at 600VAC. The bolt-on connection torques directly to the bus for a vibration-resistant joint, which is why it is preferred in MCC and switchboard applications over plug-on styles. HACR and HID rated, reverse-feed capable, and supplied with TCAL12 lugs.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGE \/ ABB (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eE150 Line, Type TED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eTED136050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e50A (150A frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e600VAC, 480VAC, 240VAC, 500VDC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAIC Rating\u003c\/th\u003e\n\u003ctd\u003e18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC (UL 489)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Style\u003c\/th\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eGE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers, E150 Enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Technology\u003c\/th\u003e\n\u003ctd\u003eThermal Magnetic (LI — Long-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Adjustability\u003c\/th\u003e\n\u003ctd\u003eFixed Thermal \/ Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWire Range\u003c\/th\u003e\n\u003ctd\u003e#14–2 AWG (Cu), #12–2 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccessories Included\u003c\/th\u003e\n\u003ctd\u003eTCAL12 Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable Options\u003c\/th\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL 489, CSA C22.2 No. 5, NEMA AB 1, HACR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eUL, CSA, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConstruction Features\u003c\/th\u003e\n\u003ctd\u003eHACR Rated, HID Rated, Reverse Feed Capable, Non-Interchangeable Trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Dimensions\u003c\/th\u003e\n\u003ctd\u003e12 x 9 x 9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Weight\u003c\/th\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the interrupting rating of the TED136050?\u003c\/h3\u003e\n\u003cp\u003e18kA at 240VAC and 480VAC, 14kA at 600VAC, and 10kA at 250VDC and 500VDC.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the TED136050 and the THED136050?\u003c\/h3\u003e\n\u003cp\u003eInterrupting capacity. The THED is the high-interrupting version of the same E150 frame, rated 25kA at 480VAC and 65kA at 240VAC. If your fault-current study shows more than 18kA available at the panel, specify the THED.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the TED136050 and the TED134050?\u003c\/h3\u003e\n\u003cp\u003eVoltage class. The \"6\" designates 600V and the \"4\" designates 480V maximum.\u003c\/p\u003e\n\u003ch3\u003eCan the TED136050 be used in a motor control center?\u003c\/h3\u003e\n\u003cp\u003eYes. The bolt-on connection suits MCC buckets and other vibration-prone installations, and it is listed for GE A-Series and Spectra assemblies.\u003c\/p\u003e\n\u003ch3\u003eWhat wire sizes does the TED136050 accept?\u003c\/h3\u003e\n\u003cp\u003e#14–2 AWG copper or #12–2 AWG aluminum through the supplied TCAL12 lugs.\u003c\/p\u003e\n\u003ch3\u003eCan the TED136050 be reverse fed?\u003c\/h3\u003e\n\u003cp\u003eYes. Reverse feed is permitted with no line\/load marking restriction under UL 489.\u003c\/p\u003e\n\u003ch3\u003eIs the 50A trip rating adjustable?\u003c\/h3\u003e\n\u003cp\u003eNo. The trip unit is fixed and non-interchangeable.\u003c\/p\u003e\n\u003ch3\u003eIs the TED136050 UL listed?\u003c\/h3\u003e\n\u003cp\u003eYes. It is UL 489 listed, CSA certified to C22.2 No. 5, CE marked, and HACR rated.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395652169976,"sku":"TED136050-N","price":435.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/TED134_cb2de3a4-f64b-4876-b6b6-9891b076dd8c.webp?v=1789326179"},{"product_id":"thed136020-ge-molded-case-circuit-breaker-feed-thru-20-amp-3-pole-600-volt","title":"THED136020 - GE - Molded Case Circuit Breaker Feed-Thru - 20 Amp - 3 Pole - 600 Volt","description":"\u003cdiv class=\"tab-content--body\" id=\"tabb5a7adde1af5c87d7fd797b6245c2a39\"\u003e\n\u003cdiv class=\"tab-content--heading-text\"\u003eDescription\u003c\/div\u003e\nEngineered for commercial applications, the THED136020 is a 3-pole, 20A molded case circuit breaker from GE's E-Frame family. It provides reliable thermal-magnetic protection with fixed long-time and instantaneous trip functions. This bolt-on MCCB is designed to mount into GE A-Series and Spectra Series panelboards, as well as motor control centers. It serves as a high-interrupting replacement for standard TED136020 breakers. Rated for 600VAC, it delivers 25kAIC at 480V and is HACR certified.\u003c\/div\u003e\n\u003cdiv class=\"tab-content--body\" id=\"tab17989744c0ba77bb014035ff2d0a5e50\"\u003e\n\u003cdiv class=\"tab-content--heading-text\"\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"md-flex jsProductUpdate jsProductReplace\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eABB \/ General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTHED136020-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC, 480VAC, 600VAC, 250VDC, 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAIC Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFor Use With\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eGE A-Series Panelboards, GE Spectra Series Panelboards, Motor Control Centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLong-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Adjustability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Thermal, Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire Gauge\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e14-3 AWG (Cu), 12-1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AWG (Cu), 1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMin Wire\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG (Cu), 12 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Lugs (TCAL12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 5, NEMA AB 1, UL 489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApproval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA, HACR, HID, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemp Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e40C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstruction Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHACR Rated, High Interrupting Capacity, Reverse Feed, Non-Interchangeable Trip, Common Trip, Quick-Make\/Quick-Break, Trip-Free Mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395653873912,"sku":"THED136020-N","price":529.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/THED136020-R.webp?v=1778786186"},{"product_id":"thed136030-ge-30a-3-pole-600v-feed-thru-mccb","title":"THED136030 - GE - 30A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eGE THED136030\u003c\/strong\u003e is a 3-pole, 30-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by General Electric (now ABB), the THED series is a trusted choice for commercial and industrial branch circuit and feeder protection in three-phase 600V electrical distribution systems. Its feed-through design makes it suitable for panelboard main breaker and service entrance applications.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eTHED136030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE \/ ABB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 18kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eTHED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main circuit breaker and service entrance applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip provides reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e30-amp rating for light industrial and commercial branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eCompact THED frame compatible with GE panelboards and switchboards\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed for NEC compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30A branch circuit and feeder protection in 600V three-phase panels\u003c\/li\u003e\n\u003cli\u003eSmall motor branch circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial building sub-panel main breakers\u003c\/li\u003e\n\u003cli\u003eIndustrial control panel branch circuit protection\u003c\/li\u003e\n\u003cli\u003eService entrance protection in light industrial facilities\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the GE THED136030 circuit breaker?\u003c\/h3\u003e\u003cp\u003eThe GE THED136030 is a 30-amp, 3-pole, 600V thermal magnetic feed-through MCCB used to protect three-phase branch circuits and feeders in commercial and industrial panelboards and switchboards.\u003c\/p\u003e\u003ch3\u003eWho manufactures the GE THED136030 now?\u003c\/h3\u003e\u003cp\u003eThe GE industrial circuit breaker product line, including the THED series, was acquired by ABB. The THED136030 may be sourced as a GE or ABB equivalent depending on manufacturing date. Alpha Brokers \u0026amp; Controls stocks original GE parts.\u003c\/p\u003e\u003ch3\u003eIs THED136030 the same as THED136030WL?\u003c\/h3\u003e\u003cp\u003eThe THED136030WL includes a factory-installed wire lug (WL suffix) for simplified installation. The base THED136030 does not include the lug accessory. Both are electrically identical; the difference is only in the included terminal hardware.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395653906680,"sku":"THED136030-N","price":668.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260204_214620_64eeb609-c3fc-4efa-90c8-401e0e53061f.jpg?v=1778786187"},{"product_id":"hdl36150-square-d-150a-3-pole-600v-feed-thru-mccb","title":"HDL36150 - Square D - 150A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HDL36150\u003c\/strong\u003e is a 3-pole, 150-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by Schneider Electric, this HD-frame breaker provides dependable overload and short-circuit protection for industrial and commercial main and feeder circuits. The feed-through design makes it well-suited for service entrance and main distribution board applications where top and bottom terminal access is required.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHDL36150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main breaker and service entrance applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for accurate overload (time-delay) and short-circuit (instantaneous) protection\u003c\/li\u003e\n\u003cli\u003e150-amp rating for medium-capacity main and feeder circuits\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eCompact HD-frame fits a range of Square D panelboards and switchboards\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e150A main breaker in commercial and light industrial panelboards\u003c\/li\u003e\n\u003cli\u003eService entrance protection for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eIndustrial sub-panel feeder protection\u003c\/li\u003e\n\u003cli\u003eManufacturing facility distribution boards\u003c\/li\u003e\n\u003cli\u003eFeed-through circuit breaker in switchboard assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HDL36150?\u003c\/h3\u003e\u003cp\u003eThe Square D HDL36150 is a 150-amp, 3-pole, 600V thermal magnetic feed-through MCCB used as a main or feeder breaker in three-phase commercial and industrial electrical distribution systems up to 600VAC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between feed-thru and I-Line plug-in mounting?\u003c\/h3\u003e\u003cp\u003eFeed-through breakers connect to the bus and have separate line and load terminal connections for hard-wiring, commonly used as main breakers. I-Line plug-in breakers physically plug into a bus in a panelboard or switchboard for faster installation and removal without hard-wiring each phase.\u003c\/p\u003e\u003ch3\u003eWhat are the terminal options on the HDL36150?\u003c\/h3\u003e\u003cp\u003eThe HDL36150 has standard lug terminals on both the line (top) and load (bottom) sides, accepting conductors sized for 150A feeders per NEC requirements. Consult Square D installation documentation for specific conductor sizing and torque specifications.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395672518904,"sku":"HDL36150-N","price":799.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HDL36150-1.jpg?v=1778786496"}],"url":"https:\/\/alphabreakersandcontrols.com\/collections\/all-products.oembed?page=7","provider":"Alpha Breakers \u0026 Controls","version":"1.0","type":"link"}