{"title":"OPTIMIZED","description":"","products":[{"product_id":"bab3060h-eaton-60a-3pole-240v-bolt-on-mccb","title":"Eaton - BAB3060H 60A 3-Pole 240V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton BAB3060H\u003c\/strong\u003e is a 3-pole, 60-amp thermal magnetic molded case circuit breaker (MCCB) rated for 240VAC with bolt-on mounting. Manufactured by Eaton (formerly Cutler-Hammer), this compact BAB-frame breaker delivers reliable overload and short-circuit protection for residential and light commercial three-phase branch circuits. Its compact, easy-to-install bolt-on design makes it a versatile and cost-effective solution for 240V load centers and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eBAB3060H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton \/ Cutler-Hammer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e10kA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eBAB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCompact bolt-on design for easy installation in Eaton BAB-frame compatible load centers and panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable time-delay overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e60-amp, 240V rating for residential and light commercial three-phase branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 240V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eHigh in-stock availability for fast replacement and new installation applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e60A three-phase branch circuit protection in 240V residential and commercial load centers\u003c\/li\u003e\n\u003cli\u003eSmall motor and equipment branch circuit protection at 240V\u003c\/li\u003e\n\u003cli\u003eHVAC compressor and equipment branch circuits\u003c\/li\u003e\n\u003cli\u003eLight commercial and residential sub-panel main protection\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Eaton BAB-frame compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton BAB3060H?\u003c\/h3\u003e\u003cp\u003eThe Eaton BAB3060H is a 60-amp, 3-pole, 240V thermal magnetic bolt-on MCCB used for branch circuit protection in three-phase residential and light commercial 240V electrical distribution systems. It is a compact, cost-effective breaker commonly used in load centers and smaller panelboards.\u003c\/p\u003e\u003ch3\u003eWhat does the H suffix mean in BAB3060H?\u003c\/h3\u003e\u003cp\u003eThe H suffix in Eaton BAB-series part numbers typically denotes a specific interrupting rating or accessory option. The BAB3060H has a standard interrupting rating of 10kA at 240V. Consult Eaton product documentation for full suffix details.\u003c\/p\u003e\u003ch3\u003eIs the BAB3060H in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls keeps the Eaton BAB3060H in stock in new condition and ships quickly. Contact us for current pricing and availability.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395478958328,"sku":"BAB3060H-N","price":84.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/CB-BAB3060H-1_1800x1800_jpg.webp?v=1778783231"},{"product_id":"edb34045-square-d-45a-3pole-480v-bolt-on-mccb","title":"Square D - EDB34045 45A 3-Pole 480V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D EDB34045\u003c\/strong\u003e is a 3-pole, 45-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC with bolt-on mounting. Manufactured by Schneider Electric, this ED-frame breaker provides reliable overload and short-circuit protection for commercial and industrial three-phase branch circuits at 480V. Its compact bolt-on design ensures a secure, consistent installation in compatible Square D panelboards and load centers.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEDB34045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e45A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure, vibration-resistant installation in Square D ED-frame panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e45-amp, 480V rating for commercial and industrial three-phase branch circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole design for balanced three-phase 480V circuit protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompact ED-frame fits Square D and compatible load centers and panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e45A three-phase branch circuit protection in 480V industrial and commercial panels\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection up to 45A at 480V\u003c\/li\u003e\n\u003cli\u003eHVAC and process equipment branch circuits at 480V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility branch circuit distribution\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D ED-frame bolt-on compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D EDB34045?\u003c\/h3\u003e\u003cp\u003eThe EDB34045 is a 45-amp, 3-pole, 480V thermal magnetic bolt-on MCCB from Square D used for branch circuit and feeder protection in three-phase commercial and industrial 480V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between EDB34045 and EDB34125?\u003c\/h3\u003e\u003cp\u003eBoth are Square D ED-frame, 3-pole, 480V bolt-on thermal magnetic MCCBs. The EDB34045 is rated at 45A for lighter branch circuit applications, while the EDB34125 is rated at 125A for larger feeder and main circuits. Select based on your NEC load calculations.\u003c\/p\u003e\u003ch3\u003eIs the EDB34045 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D EDB34045 in new condition. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395489575160,"sku":"EDB34045-N","price":159.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/EDB34045-All-New-1.jpg?v=1778783425"},{"product_id":"edb34125-square-d-125a-3pole-480v-bolt-on-mccb","title":"Square D - EDB34125 125A 3-Pole 480V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D EDB34125\u003c\/strong\u003e is a 3-pole, 125-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC with bolt-on mounting. Manufactured by Schneider Electric, this ED-frame breaker delivers reliable overcurrent and short-circuit protection for industrial and commercial three-phase feeder and main circuits at 480V. The bolt-on design ensures secure, vibration-resistant installation in compatible Square D panelboards and load centers.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEDB34125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure, vibration-resistant installation in Square D ED-frame panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e125-amp, 480V rating for medium-capacity feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole design for balanced three-phase 480V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, fully NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D ED-frame accessories including shunt trip and aux contacts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e125A feeder and main circuit protection in industrial 480V panelboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) feeder circuit breakers at 480V\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial sub-panel main protection\u003c\/li\u003e\n\u003cli\u003eManufacturing facility distribution panel branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D ED-frame bolt-on compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D EDB34125?\u003c\/h3\u003e\u003cp\u003eThe EDB34125 is a 125-amp, 3-pole, 480V thermal magnetic bolt-on MCCB from Square D used for feeder and main circuit protection in three-phase commercial and industrial 480V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eHow does EDB34125 compare to EGB34125 and EJB34125?\u003c\/h3\u003e\u003cp\u003eAll three are Square D 125A, 3-pole, 480V bolt-on thermal magnetic MCCBs, but in different frame families: EDB is ED-frame, EGB is EG-frame, and EJB is EJ-frame. Frame differences affect interrupting ratings, physical dimensions, and panelboard bus compatibility. Always confirm the correct frame for your equipment before ordering.\u003c\/p\u003e\u003ch3\u003eIs the EDB34125 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D EDB34125 in new condition. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395489902840,"sku":"EDB34125-N","price":565.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/shopping-2-scaled.jpg?v=1778783434"},{"product_id":"egb34125-square-d-125a-3pole-480v-bolt-on-mccb","title":"Square D - EGB34125 125A 3-Pole 480V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D EGB34125\u003c\/strong\u003e is a 3-pole, 125-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC with bolt-on mounting. Manufactured by Schneider Electric, this EG-frame breaker delivers reliable overcurrent and short-circuit protection for industrial and commercial three-phase feeder and main circuits at 480V. Its bolt-on design provides a secure, consistent installation in compatible Square D panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEGB34125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Square D EG-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e125-amp, 480V rating for feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for three-phase 480V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D EG-frame accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e125A feeder and main protection in commercial and industrial 480V panelboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) feeder circuit breakers at 480V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility sub-panel main protection\u003c\/li\u003e\n\u003cli\u003eIndustrial distribution panel branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D EG-frame bolt-on compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D EGB34125?\u003c\/h3\u003e\u003cp\u003eThe EGB34125 is a 125-amp, 3-pole, 480V thermal magnetic bolt-on MCCB from Square D used for feeder and main circuit protection in three-phase commercial and industrial 480V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eHow does EGB34125 compare to EDB34125 and EJB34125?\u003c\/h3\u003e\u003cp\u003eAll three are Square D 125A, 3-pole, 480V bolt-on thermal magnetic MCCBs in different frame families: EG, ED, and EJ. Frame differences affect interrupting ratings, physical dimensions, and panelboard compatibility. Always confirm the required frame series for your equipment before ordering.\u003c\/p\u003e\u003ch3\u003eIs the EGB34125 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D EGB34125. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395490132216,"sku":"EGB34125-N","price":699.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/EGB34125-All-New-1.jpg?v=1778783443"},{"product_id":"ejb34125-square-d-125a-3pole-480v-bolt-on-mccb","title":"Square D - EJB34125 125A 3-Pole 480V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D EJB34125\u003c\/strong\u003e is a 3-pole, 125-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC with bolt-on mounting. Manufactured by Schneider Electric, this EJ-frame breaker provides reliable overload and short-circuit protection for industrial and commercial three-phase feeder and main circuits at 480V. Its bolt-on design ensures secure installation in compatible Square D panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEJB34125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eEJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Square D EJ-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e125-amp, 480V rating for medium-capacity feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 480V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D EJ-frame accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e125A feeder and main circuit protection in industrial 480V panelboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) feeder circuit protection at 480V\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution panels at 480V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility sub-panel main protection\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D EJ-frame bolt-on compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D EJB34125?\u003c\/h3\u003e\u003cp\u003eThe EJB34125 is a 125-amp, 3-pole, 480V thermal magnetic bolt-on MCCB from Square D used for feeder and main circuit protection in three-phase commercial and industrial 480V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between EJB34125, EGB34125, and EDB34125?\u003c\/h3\u003e\u003cp\u003eAll three are Square D 125-amp, 3-pole, 480V thermal magnetic bolt-on MCCBs, but in different frame families: EJB is EJ-frame, EGB is EG-frame, and EDB is ED-frame. Frame differences affect interrupting ratings, physical size, and panelboard compatibility. Select the correct frame based on your equipment's requirements.\u003c\/p\u003e\u003ch3\u003eIs the EJB34125 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D EJB34125. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395490394360,"sku":"EJB34125-N","price":837.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/ejb34125-All-New-1.jpg?v=1778783452"},{"product_id":"thed136030wl-ge-30a-3pole-600v-feed-thru-wire-lug-mccb","title":"GE - THED136030WL 30A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eGE THED136030WL\u003c\/strong\u003e is a 3-pole, 30-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting and factory-installed wire lugs. Manufactured by General Electric (now ABB), the THED series is a proven choice for commercial and industrial branch circuit and feeder protection in three-phase 600V systems. The WL suffix indicates factory-installed wire lugs for simplified conductor termination during installation.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eTHED136030WL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE \/ ABB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Option\u003c\/td\u003e\n\u003ctd\u003eWire Lug (WL) — Factory Installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 18kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eTHED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFactory-installed wire lugs (WL) for simplified, code-compliant conductor termination\u003c\/li\u003e\n\u003cli\u003eFeed-through mounting for main circuit breaker and service entrance applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e30-amp, 600V rating for three-phase branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30A main and branch circuit protection in 600V three-phase panelboards\u003c\/li\u003e\n\u003cli\u003eService entrance protection for light industrial facilities\u003c\/li\u003e\n\u003cli\u003eCommercial building sub-panel main breakers at 600V\u003c\/li\u003e\n\u003cli\u003eSmall motor branch circuit protection\u003c\/li\u003e\n\u003cli\u003eReplacement in GE\/ABB THED-frame feed-through panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the GE THED136030WL?\u003c\/h3\u003e\u003cp\u003eThe GE THED136030WL is a 30-amp, 3-pole, 600V thermal magnetic feed-through MCCB with factory-installed wire lugs, used to protect three-phase branch circuits and feeders in commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does WL mean on the THED136030WL?\u003c\/h3\u003e\u003cp\u003eWL stands for Wire Lug — the breaker comes with factory-installed lug terminals on both line and load sides, making conductor termination easier and faster compared to the base THED136030 which requires separate lug accessories.\u003c\/p\u003e\u003ch3\u003eIs THED136030WL the same as THED136030?\u003c\/h3\u003e\u003cp\u003eBoth are electrically identical 30A, 3-pole, 600V thermal magnetic feed-through MCCBs. The only difference is the WL suffix indicates factory-installed wire lugs are included on the THED136030WL, while the base THED136030 does not include them.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395501404408,"sku":"THED136030WL-N","price":368.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260204_214620.jpg?v=1778783681"},{"product_id":"ehd3025-eaton-25a-3pole-480v-bolt-on-mccb","title":"Eaton - EHD3025 25A 3-Pole 480V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton EHD3025\u003c\/strong\u003e is a 3-pole, 25-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC with bolt-on mounting. Manufactured by Eaton, this EHD-frame breaker delivers reliable overload and short-circuit protection for light commercial and industrial three-phase branch circuits in 480V distribution systems. Its bolt-on design provides a secure, vibration-resistant installation in compatible Eaton panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eEHD3025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eEHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Eaton EHD-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e25-amp, 480V rating for light industrial and commercial three-phase branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole design for balanced three-phase 480V circuit protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompact EHD frame for space-efficient panelboard installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e25A three-phase branch circuit protection in 480V industrial and commercial panels\u003c\/li\u003e\n\u003cli\u003eSmall motor and equipment branch circuit protection\u003c\/li\u003e\n\u003cli\u003eHVAC and control equipment branch circuits at 480V\u003c\/li\u003e\n\u003cli\u003eLight manufacturing facility branch circuit distribution\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Eaton EHD-frame compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton EHD3025?\u003c\/h3\u003e\u003cp\u003eThe Eaton EHD3025 is a 25-amp, 3-pole, 480V thermal magnetic bolt-on MCCB used for branch circuit protection in three-phase commercial and light industrial 480V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat panelboards are compatible with the Eaton EHD3025?\u003c\/h3\u003e\u003cp\u003eThe EHD3025 is designed for bolt-on installation in Eaton EHD-frame panelboards. Always verify frame and bus compatibility with your specific panelboard before installation.\u003c\/p\u003e\u003ch3\u003eIs the EHD3025 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Eaton EHD3025 in new condition. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395535778040,"sku":"EHD3025-N","price":295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/ehd3025l-1_43576afc-f15c-42e0-b2ba-e2b66db9d866.jpg?v=1778784112"},{"product_id":"hfd2150-eaton-150a-2pole-600v-bolt-on-mccb","title":"Eaton - HFD2150 150A 2-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton HFD2150\u003c\/strong\u003e is a 2-pole, 150-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. Manufactured by Eaton (formerly Cutler-Hammer), this HFD-frame, 2-pole breaker delivers reliable overcurrent and short-circuit protection for single-phase and two-wire feeder and branch circuits in commercial and industrial 600V power distribution systems. Available in reconditioned condition for cost-effective replacement applications.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHFD2150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton \/ Cutler-Hammer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHFD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e2-pole configuration for single-phase and two-wire 150A circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Eaton\/Cutler-Hammer HFD-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e150-amp, 600V rating for medium-capacity feeder and branch circuits\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eAvailable in used\/reconditioned condition — tested and inspected prior to shipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e150A single-phase feeder circuit protection in 600V commercial and industrial panels\u003c\/li\u003e\n\u003cli\u003eTwo-wire large equipment and motor circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial building single-phase distribution circuits at 600V\u003c\/li\u003e\n\u003cli\u003eIndustrial control and equipment branch circuit protection\u003c\/li\u003e\n\u003cli\u003eReplacement in Eaton HFD-frame 2-pole compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton HFD2150?\u003c\/h3\u003e\u003cp\u003eThe Eaton HFD2150 is a 150-amp, 2-pole, 600V thermal magnetic bolt-on MCCB used for overcurrent and short-circuit protection of single-phase and two-wire feeder and branch circuits in commercial and industrial 600V electrical systems.\u003c\/p\u003e\u003ch3\u003eIs the HFD2150 available new or used?\u003c\/h3\u003e\u003cp\u003eAlpha Brokers \u0026amp; Controls stocks the Eaton HFD2150 in used\/reconditioned condition. All used circuit breakers are tested and inspected before shipping to ensure reliable performance.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between HFD2150 (2-pole) and a 3-pole HFD breaker?\u003c\/h3\u003e\u003cp\u003eA 2-pole HFD breaker like the HFD2150 protects two conductors in single-phase or two-wire applications, while a 3-pole HFD breaker protects three conductors in three-phase circuits. Select based on your circuit's phase configuration.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Used","offer_id":48395540234488,"sku":"HFD2150-U","price":364.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HFD2150-All-New-1_522d0ab4-5023-4def-bd48-ac6c47576560.jpg?v=1778784199"},{"product_id":"fxd63b250-siemens-250a-3pole-600v-bolt-on-mccb","title":"Siemens - FXD63B250 250A 3-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens FXD63B250\u003c\/strong\u003e is a 3-pole, 250-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. Engineered for industrial and commercial three-phase power distribution, this FXD-frame breaker delivers high-capacity overload and short-circuit protection for large feeder and main circuits. Its robust bolt-on design ensures a secure, vibration-resistant installation in compatible Siemens panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eFXD63B250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 35kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eFXD6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on design for secure installation in Siemens FXD-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e250A high-capacity rating for large feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for three-phase 600V industrial distribution systems\u003c\/li\u003e\n\u003cli\u003eHigh interrupting capacity for demanding industrial environments\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e250A feeder and main circuit protection in industrial 600V panelboards\u003c\/li\u003e\n\u003cli\u003eLarge motor control center (MCC) feeder protection\u003c\/li\u003e\n\u003cli\u003eHeavy manufacturing and process plant main distribution\u003c\/li\u003e\n\u003cli\u003eIndustrial switchboard sub-main and feeder circuit breakers\u003c\/li\u003e\n\u003cli\u003eUtility and process industry 250A power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Siemens FXD63B250?\u003c\/h3\u003e\u003cp\u003eThe Siemens FXD63B250 is a 250-amp, 3-pole, 600V thermal magnetic bolt-on MCCB used as a main or feeder circuit breaker in heavy industrial and commercial three-phase 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat panelboards are compatible with the FXD63B250?\u003c\/h3\u003e\u003cp\u003eThe FXD63B250 uses bolt-on mounting and is compatible with Siemens FXD6-frame panelboards and switchboards. Always verify frame and bus compatibility with your specific equipment before installation.\u003c\/p\u003e\u003ch3\u003eIs the FXD63B250 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Siemens FXD63B250 in new condition. Contact us for current pricing and availability.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395575263480,"sku":"FXD63B250-N","price":674.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/FXD63B250L-All-New-1_4963d693-b992-415d-ad54-560ebde96316.jpg?v=1778784839"},{"product_id":"hgb2b100b-siemens-100a-2pole-600v-bolt-on-mccb","title":"Siemens - HGB2B100B 100A 2-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens HGB2B100B\u003c\/strong\u003e is a 2-pole, 100-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. This HGB-frame, 2-pole breaker delivers reliable overcurrent and short-circuit protection for single-phase and two-phase branch and feeder circuits in commercial and industrial 600V power distribution systems. Its bolt-on design provides a secure installation in compatible Siemens panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHGB2B100B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e2-pole design for single-phase and two-wire 100A circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Siemens HGB-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e100-amp, 600V rating for medium-capacity branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompact HGB frame for efficient switchboard installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e100A single-phase feeder and branch circuit protection in 600V panels\u003c\/li\u003e\n\u003cli\u003eTwo-wire equipment and motor circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial single-phase distribution circuits\u003c\/li\u003e\n\u003cli\u003eControl equipment and instrumentation panel feeders\u003c\/li\u003e\n\u003cli\u003eReplacement in Siemens HGB-frame 2-pole compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Siemens HGB2B100B?\u003c\/h3\u003e\u003cp\u003eThe Siemens HGB2B100B is a 100-amp, 2-pole, 600V thermal magnetic bolt-on MCCB used for overcurrent and short-circuit protection of single-phase and two-wire branch and feeder circuits in commercial and industrial 600V electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between HGB2B100B (2-pole) and HGB3B020B (3-pole)?\u003c\/h3\u003e\u003cp\u003eThe HGB2B100B is a 2-pole, 100A breaker for single-phase and two-wire circuits, while HGB3B020B is a 3-pole, 20A breaker for three-phase circuits. Both are Siemens HGB-frame bolt-on MCCBs, but differ in pole count and amperage rating.\u003c\/p\u003e\u003ch3\u003eIs the HGB2B100B in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Siemens HGB2B100B. Contact us for current availability and pricing.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395578343672,"sku":"HGB2B100B-N","price":174.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260210_231928.jpg?v=1778784890"},{"product_id":"hgb3b020b-siemens-20a-3pole-600v-bolt-on-mccb","title":"Siemens - HGB3B020B 20A 3-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens HGB3B020B\u003c\/strong\u003e is a 3-pole, 20-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. This HGB-frame breaker delivers reliable overload and short-circuit protection for commercial and industrial three-phase branch circuits at 600V. Its bolt-on design ensures secure, vibration-resistant installation in compatible Siemens panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHGB3B020B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure installation in Siemens HGB-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e20-amp, 600V rating for light commercial and industrial three-phase branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V circuit protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompact HGB frame for space-efficient installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e20A three-phase branch circuit protection in 600V commercial and industrial panels\u003c\/li\u003e\n\u003cli\u003eControl panel and small equipment branch circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eLight industrial branch circuits and instrumentation feeders\u003c\/li\u003e\n\u003cli\u003eManufacturing facility small branch circuit distribution\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Siemens HGB-frame compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Siemens HGB3B020B?\u003c\/h3\u003e\u003cp\u003eThe Siemens HGB3B020B is a 20-amp, 3-pole, 600V thermal magnetic bolt-on MCCB used for branch circuit protection in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does the B suffix mean in HGB3B020B?\u003c\/h3\u003e\u003cp\u003eIn Siemens HGB-series part numbers, the trailing B typically indicates a specific factory-configured terminal or mounting option. Consult Siemens product documentation for the full suffix breakdown for this model.\u003c\/p\u003e\u003ch3\u003eIs the HGB3B020B in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Siemens HGB3B020B. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395579916536,"sku":"HGB3B020B-N","price":197.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260210_234150.jpg?v=1778784923"},{"product_id":"jxd63b400-siemens-400a-3pole-600v-bolt-on-mccb","title":"Siemens - JXD63B400 400A 3-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens JXD63B400\u003c\/strong\u003e is a 3-pole, 400-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. Engineered for heavy industrial and commercial three-phase power distribution, this JXD-frame breaker delivers high-capacity overload and short-circuit protection for large feeder and main circuits. The bolt-on design provides a secure, vibration-resistant installation in compatible Siemens panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJXD63B400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 35kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJXD6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on design for secure installation in Siemens JXD-frame compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e400A high-capacity rating for main and large feeder circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V industrial distribution systems\u003c\/li\u003e\n\u003cli\u003eHigh interrupting capacity for demanding industrial environments\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e400A main and large feeder circuit protection in industrial 600V panelboards\u003c\/li\u003e\n\u003cli\u003eHeavy manufacturing plant main distribution protection\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) main incoming feeder protection\u003c\/li\u003e\n\u003cli\u003eIndustrial switchboard main circuit breaker applications\u003c\/li\u003e\n\u003cli\u003eUtility and process industry high-capacity power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Siemens JXD63B400?\u003c\/h3\u003e\u003cp\u003eThe Siemens JXD63B400 is a 400-amp, 3-pole, 600V thermal magnetic bolt-on MCCB used as a main or large feeder circuit breaker in heavy industrial and commercial three-phase 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat panelboards are compatible with the JXD63B400?\u003c\/h3\u003e\u003cp\u003eThe JXD63B400 uses bolt-on mounting and is compatible with Siemens JXD6-frame panelboards and switchboards. Always verify frame and bus compatibility with your specific equipment before installation.\u003c\/p\u003e\u003ch3\u003eIs the JXD63B400 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Siemens JXD63B400 in new condition and ships quickly. Contact us for current pricing and availability.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395582210296,"sku":"JXD63B400-N","price":534.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/shopping-scaled.jpg?v=1778784946"},{"product_id":"lgb3b090b-siemens-90a-3pole-600v-bolt-on-mccb","title":"Siemens - LGB3B090B 90A 3-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens LGB3B090B\u003c\/strong\u003e is a 3-pole, 90-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. Engineered for industrial and commercial three-phase power distribution, this LGB-frame breaker delivers reliable overload and short-circuit protection. Its bolt-on design provides a secure, vibration-resistant connection in compatible Siemens panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLGB3B090B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e90A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eLGB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on design for secure, vibration-resistant mounting in Siemens-compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable time-delay overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e90-amp, 600V rating for industrial and commercial branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003e3-pole design for balanced three-phase 600V protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eField-installable accessories available for enhanced functionality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e90A three-phase branch and feeder circuit protection in 600V industrial panels\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit and feeder protection in switchboards\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution panels up to 600V\u003c\/li\u003e\n\u003cli\u003eHVAC and process equipment feeders at 600V\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Siemens LGB-frame compatible panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Siemens LGB3B090B?\u003c\/h3\u003e\u003cp\u003eThe Siemens LGB3B090B is a 90-amp, 3-pole, 600V thermal magnetic bolt-on MCCB used for branch circuit and feeder protection in three-phase industrial and commercial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does the B suffix mean in LGB3B090B?\u003c\/h3\u003e\u003cp\u003eThe B suffix in Siemens LGB-series part numbers typically indicates a specific terminal or accessory configuration. Consult Siemens product documentation for the exact meaning and available options for this model.\u003c\/p\u003e\u003ch3\u003eIs the LGB3B090B in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Siemens LGB3B090B. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395584045304,"sku":"LGB3B090B-N","price":249.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/8OqVHdzS-LGB3B090B-All-New-1_4d5b4ac0-f708-4b34-a893-961edbd727ce.jpg?v=1778784971"},{"product_id":"bda36100-square-d-100a-3pole-600v-iline-thermal-magnetic-mccb","title":"Square D - BDA36100 100A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D BDA36100\u003c\/strong\u003e is a 3-pole, 100-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this BD-frame breaker provides reliable overcurrent and short-circuit protection for industrial and commercial three-phase feeder and branch circuits at 600V. Its I-Line plug-in interface allows for fast, secure installation in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eBDA36100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eBD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for fast, reliable installation in Square D BD-frame switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for accurate overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e100A rating for industrial and commercial feeder and branch circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003e3-pole design for complete three-phase 600V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D BD-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e100A feeder and branch circuit protection in industrial 600V switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) branch feeder circuit breakers\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution panels at 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility equipment feeders\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D BD-frame I-Line compatible switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D BDA36100?\u003c\/h3\u003e\u003cp\u003eThe BDA36100 is a 100-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB from Square D used for feeder and branch circuit protection in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between BDA36100 and BJA36100?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 100-amp, 3-pole, 600V I-Line thermal magnetic MCCBs, but in different frame families: BDA is BD-frame and BJA is BJ-frame. Frame differences affect interrupting ratings, physical dimensions, and compatible switchboard bus types. Verify the required frame for your equipment before ordering.\u003c\/p\u003e\u003ch3\u003eIs the BDA36100 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D BDA36100. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395601608952,"sku":"BDA36100-N","price":506.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/square-d-bda36100-3-pole-100-amp-600v-circuit-breaker-front-600.jpg?v=1778785264"},{"product_id":"bja260201-square-d-20a-2pole-600v-iline-thermal-magnetic-mccb","title":"Square D - BJA260201 20A 2-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D BJA260201\u003c\/strong\u003e is a 2-pole, 20-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this BJ-frame, 2-pole breaker provides reliable overcurrent and short-circuit protection for single-phase and two-phase branch circuits in 600V commercial and industrial distribution systems. The I-Line plug-in design enables fast installation in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eBJA260201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eBJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e2-pole configuration for single-phase and two-wire branch circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D BJ-frame switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e20-amp, 600V rating for light branch circuit applications\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompact design for space-efficient switchboard installations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e20A single-phase branch circuit protection in 600V industrial and commercial switchboards\u003c\/li\u003e\n\u003cli\u003eTwo-wire equipment and lighting branch circuit protection\u003c\/li\u003e\n\u003cli\u003eControl panel and instrumentation branch circuits at 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility two-pole branch circuit distribution\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D BJ-frame I-Line compatible 2-pole applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D BJA260201?\u003c\/h3\u003e\u003cp\u003eThe BJA260201 is a 20-amp, 2-pole, 600V thermal magnetic I-Line plug-in MCCB from Square D used for branch circuit protection in single-phase and two-wire 600V commercial and industrial electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between BJA260201 (2-pole) and BJA36020 (3-pole)?\u003c\/h3\u003e\u003cp\u003eThe BJA260201 is a 2-pole breaker protecting two conductors, while the BJA36020 is a 3-pole breaker protecting three conductors for three-phase circuits. Use the 2-pole for single-phase or two-wire applications and the 3-pole for three-phase circuits.\u003c\/p\u003e\u003ch3\u003eIs the BJA260201 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D BJA260201. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395601772792,"sku":"BJA260201-N","price":564.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/square-d-bja260201-2-pole-20-amp-600v-circuit-breaker-front-600.jpg?v=1778785266"},{"product_id":"bja36020-square-d-20a-3pole-600v-iline-thermal-magnetic-mccb","title":"Square D - BJA36020 20A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D BJA36020\u003c\/strong\u003e is a 3-pole, 20-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this BJ-frame breaker provides reliable overload and short-circuit protection for commercial and industrial three-phase branch circuits in 600V electrical distribution systems. Its compact I-Line plug-in design makes it easy to install and replace in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eBJA36020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eBJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for tool-free installation in Square D BJ-frame switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e20-amp, 600V rating for light industrial and commercial three-phase branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for balanced three-phase protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D BJ-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e20A three-phase branch circuit protection in 600V industrial panels\u003c\/li\u003e\n\u003cli\u003eControl equipment and small motor branch circuit protection\u003c\/li\u003e\n\u003cli\u003eManufacturing facility distribution switchboard branch circuits\u003c\/li\u003e\n\u003cli\u003eCommercial building branch circuits at 600V\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Square D BJ-frame I-Line compatible switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D BJA36020?\u003c\/h3\u003e\u003cp\u003eThe BJA36020 is a 20-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB from Square D used for branch circuit protection in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eHow does the BJA36020 differ from the HDA36020?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 20-amp, 3-pole, 600V thermal magnetic I-Line MCCBs, but in different frames: BJA is BJ-frame and HDA is HD-frame. Frame differences affect interrupting ratings, physical size, and switchboard bus compatibility. Always confirm the required frame type before ordering.\u003c\/p\u003e\u003ch3\u003eIs the BJA36020 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D BJA36020. Contact us for current availability and fast shipping.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395602428152,"sku":"BJA36020-N","price":514.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/square-d-bja36020-3-pole-20-amp-600v-circuit-breaker-front-600.jpg?v=1778785285"},{"product_id":"bja36100-square-d-100a-3pole-600v-iline-thermal-magnetic-mccb","title":"Square D - BJA36100 100A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D BJA36100\u003c\/strong\u003e is a 3-pole, 100-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this BJ-frame breaker provides dependable overcurrent and short-circuit protection for industrial and commercial three-phase feeder and branch circuits in 600V distribution systems. The I-Line plug-in design enables fast installation in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eBJA36100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eBJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D BJ-frame switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e100A rating for medium-capacity feeder and branch circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D BJ-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e100A feeder and branch circuit protection in industrial 600V switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) branch feeder protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution panels at 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility equipment branch circuits\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D BJ-frame I-Line compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D BJA36100?\u003c\/h3\u003e\u003cp\u003eThe BJA36100 is a 100-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB from Square D used for feeder and branch circuit protection in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between BJA36100 and BDA36100?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 100-amp, 3-pole, 600V I-Line thermal magnetic MCCBs, but in different frame families: BJA is BJ-frame and BDA is BD-frame. Frame differences affect interrupting capacity, physical size, and compatible switchboard bus types. Verify which frame your equipment requires before ordering.\u003c\/p\u003e\u003ch3\u003eIs the BJA36100 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D BJA36100 in new condition. Contact us for current availability and pricing.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395604001016,"sku":"BJA36100-N","price":481.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/square-d-bda36100-3-pole-100-amp-600v-circuit-breaker-front-600_e3ecbfae-1d41-4e60-bd16-0fd3c64b5c18.jpg?v=1778785299"},{"product_id":"hda36020-square-d-20a-3pole-600v-iline-thermal-magnetic-mccb","title":"Square D - HDA36020 20A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HDA36020\u003c\/strong\u003e is a 3-pole, 20-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this HD-frame breaker provides reliable overload and short-circuit protection for commercial and industrial three-phase branch circuits in 600V distribution systems. Its compact I-Line plug-in design makes it easy to install and replace in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHDA36020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for tool-free installation in Square D HD-frame switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e20-amp, 600V rating for light industrial and commercial three-phase branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole design for balanced three-phase 600V protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D HD-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e20A three-phase branch circuit protection in 600V industrial panels\u003c\/li\u003e\n\u003cli\u003eControl panel and small equipment branch circuit protection\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial branch circuits at 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility distribution switchboard branch circuits\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Square D HD-frame I-Line compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HDA36020?\u003c\/h3\u003e\u003cp\u003eThe Square D HDA36020 is a 20-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB used for branch circuit protection in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eHow does the HDA36020 differ from the BJA36020?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 20-amp, 3-pole, 600V I-Line plug-in thermal magnetic MCCBs, but they belong to different frame families: HDA is HD-frame and BJA is BJ-frame. Frame differences affect interrupting capacity, physical dimensions, and compatible switchboard bus types. Check your equipment's required frame before ordering.\u003c\/p\u003e\u003ch3\u003eIs the HDA36020 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D HDA36020 and ships quickly. Contact us for current availability and pricing.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395606294776,"sku":"HDA36020-N","price":504.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HDA36020-1.jpg?v=1778785360"},{"product_id":"hda36060u31x-square-d-60a-3pole-600v-iline-solid-state-mccb","title":"Square D - HDA36060U31X 60A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HDA36060U31X\u003c\/strong\u003e is a 3-pole, 60-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this HD-frame breaker features an adjustable electronic trip unit for precise overcurrent protection in industrial and commercial three-phase 600V branch and feeder circuits. The U31X rating plug provides specific adjustable trip current ranges for selective protection coordination.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHDA36060U31X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolid-state electronic trip unit with adjustable long-time, short-time, and instantaneous protection settings\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D HD-frame switchboards\u003c\/li\u003e\n\u003cli\u003e60A rating for branch and feeder circuit protection in industrial 600V systems\u003c\/li\u003e\n\u003cli\u003e3-pole design for complete three-phase 600V protection\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e60A branch and feeder circuit protection in industrial 600V distribution systems\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection requiring selective coordination\u003c\/li\u003e\n\u003cli\u003eProcess control and manufacturing facility switchboard panels\u003c\/li\u003e\n\u003cli\u003eSystems requiring adjustable electronic trip for coordination studies\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D HD-frame I-Line compatible switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HDA36060U31X?\u003c\/h3\u003e\u003cp\u003eThe HDA36060U31X is a 60-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D (Schneider Electric) used for precise adjustable overcurrent protection of branch and feeder circuits in three-phase 600V industrial electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat does the U31X suffix mean on the HDA36060U31X?\u003c\/h3\u003e\u003cp\u003eThe U31X suffix identifies the electronic trip unit rating plug configuration, which determines the minimum and maximum adjustable current pickup range of the solid-state trip. Consult Schneider Electric documentation to confirm the specific settings for U31X.\u003c\/p\u003e\u003ch3\u003eHow does HDA36060U31X compare to HGA36060U31X?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 60A, 3-pole, 600V I-Line solid-state MCCBs with U31X rating plugs, but in different frame families: HDA is HD-frame and HGA is HG-frame. Frame differences can affect interrupting capacity, accessory options, and switchboard bus compatibility. Verify which frame your equipment requires before ordering.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395606524152,"sku":"HDA36060U31X-N","price":506.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260216_124838-1.jpg?v=1778785378"},{"product_id":"hga36060u31x-square-d-60a-3pole-600v-iline-solid-state-mccb","title":"Square D - HGA36060U31X 60A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HGA36060U31X\u003c\/strong\u003e is a 3-pole, 60-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this HG-frame breaker features an adjustable electronic trip unit for precise, selective overcurrent protection in industrial and commercial three-phase 600V branch and feeder circuits.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHGA36060U31X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolid-state electronic trip unit with adjustable long-time, short-time, and instantaneous settings\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for quick installation in Square D HG-frame switchboards\u003c\/li\u003e\n\u003cli\u003e60A rating for branch and feeder circuit protection in 600V industrial systems\u003c\/li\u003e\n\u003cli\u003e3-pole design for complete three-phase protection\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e60A branch and feeder circuit protection in industrial 600V switchboards\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection requiring precise trip coordination\u003c\/li\u003e\n\u003cli\u003eProcess plant and manufacturing facility distribution panels\u003c\/li\u003e\n\u003cli\u003eSystems requiring selective coordination with adjustable trip settings\u003c\/li\u003e\n\u003cli\u003eReplacement in Square D HG-frame I-Line compatible switchgear\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HGA36060U31X?\u003c\/h3\u003e\u003cp\u003eThe HGA36060U31X is a 60-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D used for precise overcurrent protection of branch and feeder circuits in three-phase 600V industrial and commercial electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat does U31X mean in the HGA36060U31X part number?\u003c\/h3\u003e\u003cp\u003eU31X identifies the rating plug configuration of the solid-state electronic trip unit, determining the adjustable current pickup range available on the breaker. Consult Schneider Electric documentation for the specific settings ranges for the U31X plug.\u003c\/p\u003e\u003ch3\u003eHow does HGA36060U31X differ from HDA36060U31X?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 60A, 3-pole, 600V I-Line solid-state MCCBs with U31X rating plugs. The HGA36060U31X is in the HG frame and the HDA36060U31X is in the HD frame. Frame differences affect interrupting ratings, accessory compatibility, and compatible switchboard bus types.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395607539960,"sku":"HGA36060U31X-N","price":396.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/square-d-hga36060u31x-3-pole-60-amp-600v-circuit-breaker-front-600.jpg?v=1778785406"},{"product_id":"hga36125-square-d-125a-3pole-600v-iline-thermal-magnetic-mccb","title":"Square D - HGA36125 125A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HGA36125\u003c\/strong\u003e is a 3-pole, 125-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this HG-frame breaker delivers dependable overcurrent and short-circuit protection for industrial and commercial feeder and main circuits in three-phase 600V distribution systems. The I-Line plug-in design allows for quick, reliable installation in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHGA36125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D HG-frame switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e125A rating for medium-capacity feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D HG-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e125A feeder and branch circuit protection in 600V industrial switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) branch feeder protection\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial main sub-panel protection at 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing plant distribution panels\u003c\/li\u003e\n\u003cli\u003eReplacement for Square D HG-frame I-Line compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HGA36125?\u003c\/h3\u003e\u003cp\u003eThe HGA36125 is a 125-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB from Square D used for feeder and branch circuit protection in three-phase 600V commercial and industrial electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between HGA36125 and HGA36060U31X?\u003c\/h3\u003e\u003cp\u003eThe HGA36125 is rated at 125A with a fixed thermal magnetic trip, while the HGA36060U31X is rated at 60A with an adjustable solid-state electronic trip unit. Both are Square D HG-frame, 600V I-Line plug-in MCCBs, but they differ in amperage, trip type, and adjustability.\u003c\/p\u003e\u003ch3\u003eIs the HGA36125 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D HGA36125 and ships quickly. Contact us for current availability and pricing.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395607769336,"sku":"HGA36125-N","price":694.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/square-d-hga36060u31x-3-pole-60-amp-600v-circuit-breaker-front-600_51e0836d-4114-472a-93f8-897f467dbfa5.jpg?v=1778785412"},{"product_id":"hja36060-square-d-60a-3pole-600v-iline-thermal-magnetic-mccb","title":"Square D - HJA36060 60A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HJA36060\u003c\/strong\u003e is a 3-pole, 60-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this HJ-frame breaker provides reliable overload and short-circuit protection for commercial and industrial three-phase branch and feeder circuits. The I-Line plug-in interface allows fast, tool-free installation in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHJA36060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for tool-free installation in Square D HJ-frame I-Line equipment\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for accurate overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e60-amp rating for industrial and commercial branch and feeder circuit applications\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D HJ-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e60A branch circuit protection in 600V three-phase industrial panels\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit and feeder protection in switchboards\u003c\/li\u003e\n\u003cli\u003eHVAC and process equipment branch circuits at 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing facility distribution panels\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Square D HJ-frame I-Line compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HJA36060?\u003c\/h3\u003e\u003cp\u003eThe HJA36060 is a 60-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB from Square D used to protect three-phase branch and feeder circuits in industrial and commercial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between HJA36060 and HGA36060U31X?\u003c\/h3\u003e\u003cp\u003eThe HJA36060 is a thermal magnetic MCCB in the HJ frame, while the HGA36060U31X is a solid-state electronic trip MCCB in the HG frame with an adjustable rating plug. The HGA36060U31X offers adjustable trip settings for selective coordination; the HJA36060 provides fixed thermal magnetic protection.\u003c\/p\u003e\u003ch3\u003eIs the HJA36060 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D HJA36060 and offers fast shipping. Contact us for current availability and pricing.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395608555768,"sku":"HJA36060-N","price":435.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HJA36060-1.jpg?v=1778785430"},{"product_id":"jja36200-square-d-200a-3pole-600v-iline-thermal-magnetic-mccb","title":"Square D - JJA36200 200A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36200\u003c\/strong\u003e is a 3-pole, 200-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this JJ-frame breaker provides dependable overload and short-circuit protection for industrial feeder and main circuits in three-phase 600V power distribution systems. Its I-Line plug-in interface makes installation and replacement fast and straightforward in compatible Square D switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJJA36200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D JJ-frame switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e200A rating for medium-to-large industrial feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D JJ-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e200A feeder and sub-main protection in 600V three-phase switchboards\u003c\/li\u003e\n\u003cli\u003eIndustrial motor control center (MCC) feeder circuit protection\u003c\/li\u003e\n\u003cli\u003eManufacturing and process plant distribution systems\u003c\/li\u003e\n\u003cli\u003eCommercial facility main and sub-main circuit protection\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Square D JJ-frame I-Line equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D JJA36200?\u003c\/h3\u003e\u003cp\u003eThe Square D JJA36200 is a 200-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB used for feeder and main circuit protection in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between JJA36200 and JJA36250?\u003c\/h3\u003e\u003cp\u003eThe JJA36200 is rated at 200A while the JJA36250 is rated at 250A. Both are Square D JJ-frame, 600V, 3-pole, thermal magnetic I-Line plug-in MCCBs. Select based on your calculated load and NEC requirements.\u003c\/p\u003e\u003ch3\u003eIs the JJA36200 compatible with Square D I-Line switchboards?\u003c\/h3\u003e\u003cp\u003eYes. The JJA36200 uses I-Line plug-in mounting and is compatible with Square D switchboards and panelboards designed for JJ-frame breakers. Verify bus rating and frame compatibility before installation.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395611013368,"sku":"JJA36200-N","price":1299.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/JJA36200-New-1_00f769cb-5ef0-404d-8347-994d10564bbb-1.jpg?v=1778785481"},{"product_id":"jja36250-square-d-250a-3pole-600v-iline-thermal-magnetic-mccb","title":"Square D - JJA36250 250A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36250\u003c\/strong\u003e is a 3-pole, 250-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this JJ-frame breaker delivers dependable overload and short-circuit protection for large industrial feeder and main circuits in three-phase 600V power distribution systems. The I-Line plug-in interface enables fast, reliable installation in compatible Square D switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJJA36250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for quick installation in Square D JJ-frame compatible switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e250A rating for large industrial feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V system protection\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D JJ-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e250A feeder and sub-main circuit protection in industrial 600V switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) feeder circuit breakers\u003c\/li\u003e\n\u003cli\u003eHeavy manufacturing and process plant distribution panels\u003c\/li\u003e\n\u003cli\u003eCommercial building main and sub-main protection\u003c\/li\u003e\n\u003cli\u003eIndustrial three-phase 600V power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D JJA36250?\u003c\/h3\u003e\u003cp\u003eThe Square D JJA36250 is a 250-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB used for overcurrent and short-circuit protection of feeder and main circuits in three-phase 600V industrial and commercial electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between JJA36250 and JJA36250U31X or JJA36250U33X?\u003c\/h3\u003e\u003cp\u003eThe JJA36250 uses a fixed thermal magnetic trip unit, while the U31X, U33X, and U44X variants use an adjustable solid-state electronic trip unit. The solid-state versions offer adjustable settings for selective coordination; the thermal magnetic version provides fixed, straightforward protection at a lower cost.\u003c\/p\u003e\u003ch3\u003eIs the JJA36250 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D JJA36250 in new condition and ships quickly. Contact us to confirm current availability and lead time.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395611046136,"sku":"JJA36250-N","price":1199.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/JJA36250-New-1_e02139e4-b5f9-4658-863c-b01e55e2b45e.jpg?v=1778785483"},{"product_id":"jja36250u31x-square-d-250a-3pole-600v-iline-solid-state-mccb","title":"Square D JJA36250U31X 250A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36250U31X\u003c\/strong\u003e is a 3-pole, 250-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this JJ-frame breaker features an adjustable electronic trip unit for precise overcurrent protection of large industrial feeder and main circuits in three-phase 600V systems.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJJA36250U31X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable solid-state trip unit with long-time, short-time, and instantaneous settings for selective coordination\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D JJ-frame compatible switchboards\u003c\/li\u003e\n\u003cli\u003e250A rating for large industrial feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V protection\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial feeder and sub-main protection in 600V switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) main incoming protection\u003c\/li\u003e\n\u003cli\u003eHeavy manufacturing and process facility power distribution\u003c\/li\u003e\n\u003cli\u003eSystems requiring selective coordination with adjustable trip settings\u003c\/li\u003e\n\u003cli\u003eData center and critical infrastructure 600V feeder circuits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D JJA36250U31X?\u003c\/h3\u003e\u003cp\u003eThe JJA36250U31X is a 250-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D used to protect large feeder and main circuits in three-phase 600V industrial and commercial electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does U31X mean in the JJA36250U31X part number?\u003c\/h3\u003e\u003cp\u003eThe U31X suffix identifies the rating plug configuration of the solid-state electronic trip unit, which sets the adjustable current pickup range. This differs from U33X and U44X variants. Consult Schneider Electric documentation to confirm the correct plug for your coordination study.\u003c\/p\u003e\u003ch3\u003eHow does the JJA36250U31X differ from JJA36250U33X or JJA36250U44X?\u003c\/h3\u003e\u003cp\u003eAll three are Square D 250A, 3-pole, 600V I-Line solid-state JJ-frame MCCBs. The U31X, U33X, and U44X suffixes indicate different rating plug configurations that affect the adjustable trip current range of the electronic trip unit. Select the correct suffix based on your protection coordination requirements.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395611078904,"sku":"JJA36250U31X-N","price":1764.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/shopping-2-1-scaled.jpg?v=1778785485"},{"product_id":"jja36250u43x-square-d-250a-3-pole-600v-iline-solid-state-mccb","title":"Square D - JJA36250U43X 250A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36250U43X\u003c\/strong\u003e is a 3-pole, 250-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this JJ-frame electronic trip breaker delivers adjustable, highly accurate overcurrent protection for large industrial feeder circuits and main distribution applications. Available in new and used (reconditioned) condition, it is a high-performance solution for three-phase 600V systems requiring selective coordination.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJJA36250U43X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolid-state electronic trip unit with adjustable long-time, short-time, and instantaneous settings\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for quick installation in Square D JJ-frame compatible switchboards\u003c\/li\u003e\n\u003cli\u003e250-amp rating for large feeder and sub-main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600V industrial power systems\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V for demanding environments\u003c\/li\u003e\n\u003cli\u003eAvailable new and reconditioned — all units tested prior to shipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e250A feeder and main circuit protection in industrial 600V switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) main incoming feeds\u003c\/li\u003e\n\u003cli\u003eSub-main protection in large industrial and commercial facilities\u003c\/li\u003e\n\u003cli\u003eProcess plant and manufacturing facility power distribution\u003c\/li\u003e\n\u003cli\u003eSelective coordination systems requiring adjustable trip settings\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D JJA36250U43X?\u003c\/h3\u003e\u003cp\u003eThe JJA36250U43X is a 250-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D (Schneider Electric). It is used for main and feeder overcurrent protection in three-phase industrial and commercial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between JJA36250U43X and JJA36250U44X?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 250A, 3-pole, 600V I-Line solid-state MCCBs in the JJ frame. The U43X and U44X suffixes indicate different rating plug configurations for the electronic trip unit, which affects the adjustable current pickup range. Consult Schneider Electric to confirm which plug is correct for your system coordination study.\u003c\/p\u003e\u003ch3\u003eIs the JJA36250U43X available in used condition?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the JJA36250U43X in both new and used (reconditioned) condition. All used breakers are inspected and tested before shipping to ensure reliable operation.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395611111672,"sku":"JJA36250U43X-N","price":7150.0,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":48395611144440,"sku":"JJA36250U43X-U","price":7150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/CB-JJA36250U43X-1.jpg?v=1778785486"},{"product_id":"lja36400u43x-square-d-400a-3-pole-600v-iline-solid-state-mccb","title":"Square D - LJA36400U43X 400A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D LJA36400U43X\u003c\/strong\u003e is a 3-pole, 400-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this LJ-frame breaker features an adjustable electronic solid-state trip unit for precise, selective overcurrent protection in high-capacity industrial feeder and main circuit applications. It combines high interrupting capacity with flexible trip settings for demanding three-phase 600V power systems.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLJA36400U43X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eLJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable solid-state trip unit with long-time, short-time, and instantaneous settings for selective coordination\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D LJ-frame I-Line switchboards\u003c\/li\u003e\n\u003cli\u003e400-amp capacity for heavy industrial main and feeder circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V protection\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e400A main and feeder breaker in heavy industrial I-Line switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) main incoming protection\u003c\/li\u003e\n\u003cli\u003eLarge manufacturing plant main distribution panels\u003c\/li\u003e\n\u003cli\u003eProcess plant and refinery electrical distribution systems\u003c\/li\u003e\n\u003cli\u003eHigh fault-current industrial environments requiring 65kA interrupting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D LJA36400U43X?\u003c\/h3\u003e\u003cp\u003eThe LJA36400U43X is a 400-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D used for main and feeder circuit protection in heavy industrial three-phase 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does U43X mean in the LJA36400U43X part number?\u003c\/h3\u003e\u003cp\u003eThe U43X suffix on Square D solid-state MCCBs identifies the rating plug configuration of the electronic trip unit, which determines the adjustable current range (pickup and delay settings) available on the breaker. Consult Schneider Electric documentation for the specific ranges associated with U43X.\u003c\/p\u003e\u003ch3\u003eIs the LJA36400U43X available as new and used?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D LJA36400U43X in new condition. Contact us for current pricing and availability.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395611832568,"sku":"LJA36400U43X-N","price":2634.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/EfSZpneA-LJA36400U33X_Illustration_Front.jpg?v=1778785499"},{"product_id":"la36400-square-d-400a-3-pole-600v-iline-mccb","title":"Square D - LA36400 400A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D LA36400\u003c\/strong\u003e is a 3-pole, 400-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, the LA-frame breaker delivers high-capacity overcurrent and short-circuit protection for large industrial feeder and main circuits. The I-Line plug-in interface allows for fast installation and replacement in compatible Square D switchboards and panelboards, making it a standard choice for heavy industrial power distribution.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLA36400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e30kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eLA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in design for quick installation and removal in Square D I-Line switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e400-amp capacity for high-current main and feeder circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600VAC industrial distribution systems\u003c\/li\u003e\n\u003cli\u003eLA frame standard in Square D I-Line switchboard applications\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e400A main or feeder breaker in industrial I-Line switchboards\u003c\/li\u003e\n\u003cli\u003eLarge motor control center (MCC) incoming feeder protection\u003c\/li\u003e\n\u003cli\u003eHeavy manufacturing plant distribution panels\u003c\/li\u003e\n\u003cli\u003eIndustrial sub-main circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eUtility and process industry high-capacity power distribution\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D LA36400?\u003c\/h3\u003e\u003cp\u003eThe Square D LA36400 is a 400-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB used as a main or feeder circuit breaker in heavy industrial and commercial three-phase 600VAC switchboards and panelboards.\u003c\/p\u003e\u003ch3\u003eWhat is the interrupting rating of the LA36400?\u003c\/h3\u003e\u003cp\u003eThe Square D LA36400 has a standard interrupting capacity of 30kA at 480V. This is suitable for most industrial distribution systems; for higher available fault current environments, consider the LJA36400U43X with a solid-state trip and higher interrupting rating.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between LA36400 and LJA36400U43X?\u003c\/h3\u003e\u003cp\u003eThe LA36400 uses a thermal magnetic trip unit (fixed settings), while the LJA36400U43X uses an adjustable solid-state electronic trip unit, offering higher interrupting capacity and flexible protection coordination. The LJA is preferred for systems requiring selective coordination or higher fault-current protection.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395624939768,"sku":"LA36400-N","price":1019.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260302_154526.jpg?v=1778785708"},{"product_id":"pdg23m0050tffj-eaton-50a-3-pole-600v-feed-thru-mccb","title":"Eaton - PDG23M0050TFFJ 50A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton PDG23M0050TFFJ\u003c\/strong\u003e is a 3-pole, 50-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by Eaton, this PDG-frame breaker delivers dependable overcurrent and short-circuit protection for commercial and industrial three-phase branch and feeder circuits at 600V. The feed-through mounting makes it suitable for use in service entrance and main distribution panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003ePDG23M0050TFFJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003ePDG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main and branch circuit applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e50-amp rating for light industrial and commercial branch and feeder circuits at 600V\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase power system protection\u003c\/li\u003e\n\u003cli\u003eRobust Eaton PDG frame construction for industrial environments\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e50A three-phase branch circuit protection in 600V industrial panels\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection in commercial and industrial applications\u003c\/li\u003e\n\u003cli\u003eHVAC and process equipment feeder circuits at 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing plant branch circuit distribution\u003c\/li\u003e\n\u003cli\u003eFeed-through sub-panel main protection in 600VAC systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton PDG23M0050TFFJ?\u003c\/h3\u003e\u003cp\u003eThe Eaton PDG23M0050TFFJ is a 50-amp, 3-pole, 600V thermal magnetic feed-through MCCB used to protect three-phase branch and feeder circuits in industrial and commercial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eIs the PDG23M0050TFFJ available in feed-thru only, or other mounting styles?\u003c\/h3\u003e\u003cp\u003eThe PDG23M0050TFFJ is specifically configured for feed-through (feed-thru) mounting. Eaton offers other PDG series models with different mounting configurations. Check the full PDG series catalog or contact Alpha Brokers \u0026amp; Controls for alternatives.\u003c\/p\u003e\u003ch3\u003eWhat is the interrupting capacity of the PDG23M0050TFFJ?\u003c\/h3\u003e\u003cp\u003eThe PDG23M0050TFFJ carries an interrupting rating of 65kA at 240V and 25kA at 600V, making it suitable for the majority of commercial and industrial 600V power systems.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395627823352,"sku":"PDG23M0050TFFJ-N","price":534.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/PDG23M0050TFFJ-All-New-1_664ebb18-55c3-4f45-9104-cfe3132a24a9.jpg?v=1778785760"},{"product_id":"pdg23m0125tffj-eaton-125a-3-pole-600v-feed-thru-mccb","title":"Eaton - PDG23M0125TFFJ 125A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton PDG23M0125TFFJ\u003c\/strong\u003e is a 3-pole, 125-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by Eaton, this PDG-frame breaker provides reliable overcurrent and short-circuit protection for commercial and industrial three-phase feeder and main circuits. Its feed-through configuration makes it well-suited for panelboard main breaker and service entrance applications at 600V.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003ePDG23M0125TFFJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e125A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003ePDG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main breaker and service entrance applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip mechanism for accurate overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e125-amp rating for main and feeder circuit applications in 600V systems\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase power protection\u003c\/li\u003e\n\u003cli\u003eHeavy-duty PDG frame construction for industrial reliability\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e125A main circuit breaker in industrial and commercial 600V panelboards\u003c\/li\u003e\n\u003cli\u003eService entrance protection for three-phase 600VAC systems\u003c\/li\u003e\n\u003cli\u003eFeeder circuit protection in manufacturing and process facilities\u003c\/li\u003e\n\u003cli\u003eSub-panel main protection in large commercial buildings\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Eaton PDG-frame compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton PDG23M0125TFFJ?\u003c\/h3\u003e\u003cp\u003eThe Eaton PDG23M0125TFFJ is a 125-amp, 3-pole, 600V thermal magnetic feed-through MCCB used to protect main and feeder circuits in three-phase commercial and industrial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eCan the PDG23M0125TFFJ be used as a service entrance breaker?\u003c\/h3\u003e\u003cp\u003eYes. The feed-through mounting and 125A, 600V rating make the PDG23M0125TFFJ suitable for service entrance and main distribution board applications. Verify compliance with local codes and NEC requirements for your specific installation.\u003c\/p\u003e\u003ch3\u003eHow does the PDG23M0125TFFJ compare to PDG23M0200TFFJ?\u003c\/h3\u003e\u003cp\u003eBoth are Eaton PDG-frame, 600V, 3-pole, thermal magnetic feed-through MCCBs. The PDG23M0125TFFJ is rated at 125A, while the PDG23M0200TFFJ is rated at 200A. Choose based on your calculated load requirements per NEC.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395627856120,"sku":"PDG23M0125TFFJ-N","price":984.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/jVsx01vX-PDG23M0125TFFJ-New-1_a3910adb-c193-40ad-bfad-a76901783986_jpg.webp?v=1778785762"},{"product_id":"pdg23m0200tffj-eaton-200a-3-pole-600v-feed-thru-mccb","title":"Eaton - PDG23M0200TFFJ 200A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton PDG23M0200TFFJ\u003c\/strong\u003e is a 3-pole, 200-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by Eaton, this PDG-frame breaker delivers reliable overcurrent and fault protection for main and feeder circuits in industrial and commercial three-phase power distribution systems. The feed-through design is ideal for service entrance and main distribution board configurations.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003ePDG23M0200TFFJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003ePDG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main breaker and service entrance panelboard applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e200-amp rating for medium-to-large main and feeder circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600V system protection\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade PDG frame with robust construction\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, fully NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e200A main circuit breaker in industrial and commercial 600V panelboards\u003c\/li\u003e\n\u003cli\u003eService entrance protection for three-phase systems\u003c\/li\u003e\n\u003cli\u003eFeeder circuit protection in manufacturing facilities\u003c\/li\u003e\n\u003cli\u003eSub-main breaker in large-scale commercial electrical distribution\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in Eaton PDG-compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton PDG23M0200TFFJ?\u003c\/h3\u003e\u003cp\u003eThe Eaton PDG23M0200TFFJ is a 200-amp, 3-pole, 600V thermal magnetic feed-through MCCB used as a main or feeder circuit breaker in three-phase industrial and commercial 600V electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between PDG23M0200TFFJ and PDG23M0225TFFJ?\u003c\/h3\u003e\u003cp\u003eThe primary difference is the amperage rating: the PDG23M0200TFFJ is rated at 200A, while the PDG23M0225TFFJ is rated at 225A. Both share the same PDG frame, 600V rating, feed-through mount, and thermal magnetic trip type. Select based on your circuit's load requirements and NEC calculations.\u003c\/p\u003e\u003ch3\u003eIs the PDG23M0200TFFJ in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Eaton PDG23M0200TFFJ and ships quickly. Contact us to confirm current availability.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395627921656,"sku":"PDG23M0200TFFJ-N","price":945.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/PDG23M0200TFFJ-All-New-1_43235bad-2f05-47f4-8a53-b3abe02ad193.jpg?v=1778785763"},{"product_id":"pdg23m0225tffj-eaton-225a-3-pole-600v-bolt-on-mccb","title":"Eaton - PDG23M0225TFFJ 225A 3-Pole 600V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton PDG23M0225TFFJ\u003c\/strong\u003e is a 3-pole, 225-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with bolt-on mounting. Manufactured by Eaton, the PDG series is designed for reliable main and feeder circuit protection in industrial and commercial three-phase 600V power distribution systems. The bolt-on configuration ensures secure mechanical attachment and consistent contact pressure in panelboards and switchboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003ePDG23M0225TFFJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e225A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003ePDG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBolt-on mounting for secure, vibration-resistant installation in compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable time-delay overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e225-amp capacity for main circuit and large feeder protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V power systems\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade PDG frame construction\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e225A main circuit breaker in commercial and industrial panelboards\u003c\/li\u003e\n\u003cli\u003eFeeder circuit protection in 600V three-phase systems\u003c\/li\u003e\n\u003cli\u003eManufacturing plant distribution panel main breaker\u003c\/li\u003e\n\u003cli\u003eIndustrial switchboard branch circuit protection\u003c\/li\u003e\n\u003cli\u003eSub-main breaker in large commercial electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Eaton PDG23M0225TFFJ?\u003c\/h3\u003e\u003cp\u003eThe Eaton PDG23M0225TFFJ is a 225-amp, 3-pole, 600V thermal magnetic bolt-on MCCB used as a main or feeder circuit breaker in three-phase industrial and commercial 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does TFFJ mean in the Eaton PDG23M0225TFFJ part number?\u003c\/h3\u003e\u003cp\u003eIn Eaton PDG series part numbers, the suffix characters indicate options such as trip rating, frame size, and terminal\/lug configuration. TFFJ identifies specific factory-configured trip and accessory options. Consult Eaton product documentation for the full breakdown of suffix meanings for this model.\u003c\/p\u003e\u003ch3\u003eIs the PDG23M0225TFFJ compatible with Eaton panelboards?\u003c\/h3\u003e\u003cp\u003eYes. The PDG23M0225TFFJ is designed for bolt-on installation in Eaton and compatible third-party panelboards that accept PDG-frame MCCBs. Verify bus rating and mounting compatibility before installation.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395627987192,"sku":"PDG23M0225TFFJ-N","price":945.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/PDG23M0225TFFJ-All-New-1_7845656f-7504-4f6f-af09-ba5c394958cc.jpg?v=1778785765"},{"product_id":"ted134020-ge-20a-3pole-480v-feed-thru-mccb","title":"GE TED134020 20A 3-Pole 480V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eGE TED134020\u003c\/strong\u003e is a 3-pole, 20-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC with feed-through (feed-thru) mounting. Manufactured by General Electric (now ABB), the TED1 series delivers reliable overload and short-circuit protection for commercial and light industrial three-phase 480V branch and feeder circuits. Its feed-through configuration is suitable for main and branch breaker applications in compatible GE panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eTED134020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE \/ ABB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eTED1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main and branch circuit applications in GE-compatible panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for time-delay overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e20-amp, 480V rating for light commercial and industrial three-phase branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole design for balanced three-phase 480V circuit protection\u003c\/li\u003e\n\u003cli\u003eCompact TED1 frame for GE and compatible switchgear\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e20A three-phase branch circuit protection in 480V distribution panels\u003c\/li\u003e\n\u003cli\u003eSmall motor and equipment branch circuit protection\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial feeder circuits at 480V\u003c\/li\u003e\n\u003cli\u003eControl panel branch circuit protection\u003c\/li\u003e\n\u003cli\u003eReplacement breaker in GE\/ABB TED1-compatible equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the GE TED134020?\u003c\/h3\u003e\u003cp\u003eThe GE TED134020 is a 20-amp, 3-pole, 480V thermal magnetic feed-through MCCB used for branch circuit and feeder protection in three-phase commercial and light industrial 480V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eIs the TED134020 the same as TED134020WL?\u003c\/h3\u003e\u003cp\u003eThe TED134020WL adds a factory-installed wire lug (WL suffix) for simplified wiring connections. Both are electrically identical — the only difference is the included terminal hardware.\u003c\/p\u003e\u003ch3\u003eWhat panelboards are compatible with the GE TED134020?\u003c\/h3\u003e\u003cp\u003eThe TED134020 is designed for GE and ABB TED1-frame compatible panelboards. Always verify frame compatibility and bus rating before installation.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395651449080,"sku":"TED134020-N","price":349.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260203_153410_897af32f-a3c3-4389-bd7d-446b84e1e42a.jpg?v=1778786135"},{"product_id":"thed136030-ge-30a-3-pole-600v-feed-thru-mccb","title":"GE - THED136030 30A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eGE THED136030\u003c\/strong\u003e is a 3-pole, 30-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by General Electric (now ABB), the THED series is a trusted choice for commercial and industrial branch circuit and feeder protection in three-phase 600V electrical distribution systems. Its feed-through design makes it suitable for panelboard main breaker and service entrance applications.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eTHED136030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE \/ ABB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 18kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eTHED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main circuit breaker and service entrance applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip provides reliable overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e30-amp rating for light industrial and commercial branch and feeder circuits\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eCompact THED frame compatible with GE panelboards and switchboards\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed for NEC compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e30A branch circuit and feeder protection in 600V three-phase panels\u003c\/li\u003e\n\u003cli\u003eSmall motor branch circuit protection\u003c\/li\u003e\n\u003cli\u003eCommercial building sub-panel main breakers\u003c\/li\u003e\n\u003cli\u003eIndustrial control panel branch circuit protection\u003c\/li\u003e\n\u003cli\u003eService entrance protection in light industrial facilities\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the GE THED136030 circuit breaker?\u003c\/h3\u003e\u003cp\u003eThe GE THED136030 is a 30-amp, 3-pole, 600V thermal magnetic feed-through MCCB used to protect three-phase branch circuits and feeders in commercial and industrial panelboards and switchboards.\u003c\/p\u003e\u003ch3\u003eWho manufactures the GE THED136030 now?\u003c\/h3\u003e\u003cp\u003eThe GE industrial circuit breaker product line, including the THED series, was acquired by ABB. The THED136030 may be sourced as a GE or ABB equivalent depending on manufacturing date. Alpha Brokers \u0026amp; Controls stocks original GE parts.\u003c\/p\u003e\u003ch3\u003eIs THED136030 the same as THED136030WL?\u003c\/h3\u003e\u003cp\u003eThe THED136030WL includes a factory-installed wire lug (WL suffix) for simplified installation. The base THED136030 does not include the lug accessory. Both are electrically identical; the difference is only in the included terminal hardware.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395653906680,"sku":"THED136030-N","price":368.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260204_214620_64eeb609-c3fc-4efa-90c8-401e0e53061f.jpg?v=1778786187"},{"product_id":"hdl36150-square-d-150a-3-pole-600v-feed-thru-mccb","title":"Square D - HDL36150 150A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HDL36150\u003c\/strong\u003e is a 3-pole, 150-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by Schneider Electric, this HD-frame breaker provides dependable overload and short-circuit protection for industrial and commercial main and feeder circuits. The feed-through design makes it well-suited for service entrance and main distribution board applications where top and bottom terminal access is required.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHDL36150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main breaker and service entrance applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for accurate overload (time-delay) and short-circuit (instantaneous) protection\u003c\/li\u003e\n\u003cli\u003e150-amp rating for medium-capacity main and feeder circuits\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eCompact HD-frame fits a range of Square D panelboards and switchboards\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e150A main breaker in commercial and light industrial panelboards\u003c\/li\u003e\n\u003cli\u003eService entrance protection for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eIndustrial sub-panel feeder protection\u003c\/li\u003e\n\u003cli\u003eManufacturing facility distribution boards\u003c\/li\u003e\n\u003cli\u003eFeed-through circuit breaker in switchboard assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HDL36150?\u003c\/h3\u003e\u003cp\u003eThe Square D HDL36150 is a 150-amp, 3-pole, 600V thermal magnetic feed-through MCCB used as a main or feeder breaker in three-phase commercial and industrial electrical distribution systems up to 600VAC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between feed-thru and I-Line plug-in mounting?\u003c\/h3\u003e\u003cp\u003eFeed-through breakers connect to the bus and have separate line and load terminal connections for hard-wiring, commonly used as main breakers. I-Line plug-in breakers physically plug into a bus in a panelboard or switchboard for faster installation and removal without hard-wiring each phase.\u003c\/p\u003e\u003ch3\u003eWhat are the terminal options on the HDL36150?\u003c\/h3\u003e\u003cp\u003eThe HDL36150 has standard lug terminals on both the line (top) and load (bottom) sides, accepting conductors sized for 150A feeders per NEC requirements. Consult Square D installation documentation for specific conductor sizing and torque specifications.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395672518904,"sku":"HDL36150-N","price":524.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HDL36150-1.jpg?v=1778786496"},{"product_id":"hja36070-square-d-70a-3-pole-600v-iline-mccb","title":"Square D - HJA36070 70A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HJA36070\u003c\/strong\u003e is a 3-pole, 70-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this HJ-frame breaker provides dependable overcurrent and short-circuit protection for commercial and industrial three-phase branch and feeder circuits. The I-Line plug-in interface enables fast, reliable installation in compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHJA36070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for tool-free installation and removal from Square D I-Line equipment\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for reliable overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e70-amp rating for branch and feeder circuit applications\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600V distribution systems\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed for NEC compliance\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D HJ-frame I-Line accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial 600V three-phase branch circuit protection\u003c\/li\u003e\n\u003cli\u003eMotor feeder circuit breakers in switchboards\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial distribution panels up to 600V\u003c\/li\u003e\n\u003cli\u003eManufacturing plant equipment feeders\u003c\/li\u003e\n\u003cli\u003eHVAC and process equipment branch circuits in 600V systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HJA36070 used for?\u003c\/h3\u003e\u003cp\u003eThe HJA36070 is a 70-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB used to protect three-phase branch and feeder circuits in industrial and commercial switchboards and panelboards up to 600VAC.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between HLA36070 and HJA36070?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 70-amp, 3-pole, 600V I-Line thermal magnetic MCCBs, but they belong to different frame families. The HJ series is a higher-rated frame compared to the HL series and may offer higher interrupting capacity or different accessory compatibility. Consult Schneider Electric specifications to confirm the correct replacement or equivalent.\u003c\/p\u003e\u003ch3\u003eIs the HJA36070 in stock?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the Square D HJA36070 and offers fast shipping. Contact us for current availability and pricing.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395675205880,"sku":"HJA36070-N","price":537.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/square-d-hga36060u31x-3-pole-60-amp-600v-circuit-breaker-front-600_048f8298-57a7-4051-be1c-15a904737d49.jpg?v=1778786516"},{"product_id":"hja36150u44x-square-d-150a-3-pole-600v-iline-solid-state-mccb","title":"Square D - HJA36150U44X 150A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HJA36150U44X\u003c\/strong\u003e is a 3-pole, 150-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, the HJ-frame solid-state trip unit provides adjustable, highly accurate protection for medium-to-large industrial feeder circuits. Engineered for applications where precise protection coordination and high interrupting capacity are required in demanding three-phase systems.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHJA36150U44X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolid-state electronic trip unit with adjustable long-time, short-time, and instantaneous settings\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for straightforward installation in Square D I-Line switchboards\u003c\/li\u003e\n\u003cli\u003e150-amp rating for industrial feeder and main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for complete three-phase 600V protection\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V for demanding industrial environments\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed for NEC compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial feeder protection in 600V three-phase switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) feeder circuit protection\u003c\/li\u003e\n\u003cli\u003eSub-main breaker in industrial distribution systems\u003c\/li\u003e\n\u003cli\u003eProcess plant and manufacturing facility power distribution\u003c\/li\u003e\n\u003cli\u003eOil, gas, and petrochemical facility electrical systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HJA36150U44X?\u003c\/h3\u003e\u003cp\u003eThe HJA36150U44X is a 150-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D. It provides adjustable overcurrent and short-circuit protection for feeder and main circuits in three-phase 600V industrial and commercial electrical systems.\u003c\/p\u003e\u003ch3\u003eWhat does the U44X suffix mean on the HJA36150U44X?\u003c\/h3\u003e\u003cp\u003eThe U44X suffix on Square D solid-state MCCBs typically indicates the trip unit rating plug configuration, which sets the adjustable current range of the electronic trip unit. This affects minimum and maximum current trip settings available on the breaker.\u003c\/p\u003e\u003ch3\u003eIs the HJA36150U44X compatible with Square D I-Line panels?\u003c\/h3\u003e\u003cp\u003eYes. The HJA36150U44X features I-Line plug-in mounting compatible with Square D I-Line switchboards and panelboards designed for HJ-frame breakers. Confirm bus rating and frame compatibility before installation.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395675336952,"sku":"HJA36150U44X-N","price":3499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/CB-HJA36150U44X_1d77f426-f1bf-4715-83cb-d8da32258102.jpg?v=1778786519"},{"product_id":"jgl36225-square-d-225a-3-pole-600v-feed-thru-mccb","title":"Square D - JGL36225 225A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JGL36225\u003c\/strong\u003e is a 3-pole, 225-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with feed-through (feed-thru) mounting. Manufactured by Schneider Electric, the JG-frame design delivers reliable overcurrent and short-circuit protection for industrial and commercial main and feeder circuits. The feed-thru configuration allows the breaker to be wired from both the line and load sides, commonly used in service entrance and main distribution applications.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJGL36225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e225A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFeed-through mounting for main breaker and service entrance applications\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip mechanism for reliable overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e225-amp rating suitable for main distribution panels and sub-main feeders\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V systems\u003c\/li\u003e\n\u003cli\u003eHigh interrupting capacity for industrial environments\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, fully NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain circuit breaker in 225A three-phase distribution panels\u003c\/li\u003e\n\u003cli\u003eService entrance protection for commercial buildings\u003c\/li\u003e\n\u003cli\u003eIndustrial sub-main feeder circuit protection\u003c\/li\u003e\n\u003cli\u003eManufacturing facility main distribution boards\u003c\/li\u003e\n\u003cli\u003eFeed-through panelboard main breaker applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D JGL36225 circuit breaker?\u003c\/h3\u003e\u003cp\u003eThe Square D JGL36225 is a 225-amp, 3-pole, 600V thermal magnetic feed-through MCCB used as a main or feeder breaker in three-phase commercial and industrial electrical distribution systems up to 600VAC.\u003c\/p\u003e\u003ch3\u003eWhat does feed-thru mounting mean for the JGL36225?\u003c\/h3\u003e\u003cp\u003eFeed-through (feed-thru) mounting means the circuit breaker accepts wiring connections on both the line (top) and load (bottom) terminals, making it ideal for use as a main breaker in panelboards where power flows through the breaker to downstream distribution.\u003c\/p\u003e\u003ch3\u003eWhat is the interrupting rating of the Square D JGL36225?\u003c\/h3\u003e\u003cp\u003eThe JGL36225 has an interrupting rating of 65kA at 240V and 25kA at 600V, providing adequate fault current protection for most commercial and industrial power distribution applications.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395677532408,"sku":"JGL36225-N","price":647.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/JGL36225-1.jpg?v=1778786547"},{"product_id":"jja36250u33x-square-d-250a-3-pole-600v-iline-solid-state-mccb","title":"Square D - JJA36250U33X 250A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36250U33X\u003c\/strong\u003e is a 3-pole, 250-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Produced by Schneider Electric, this JJ-frame breaker features an adjustable solid-state electronic trip unit for highly accurate overcurrent protection. Designed for demanding three-phase industrial power systems requiring selective coordination and high fault current interruption.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJJA36250U33X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAdjustable solid-state trip unit with long-time, short-time, and instantaneous protection settings\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in design for fast, reliable installation in Square D I-Line equipment\u003c\/li\u003e\n\u003cli\u003e250A rating for heavy industrial feeder and sub-main circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole for complete three-phase 600VAC system protection\u003c\/li\u003e\n\u003cli\u003e65kA interrupting rating suitable for high fault-current environments\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed, NEC compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and feeder protection in industrial switchboards\u003c\/li\u003e\n\u003cli\u003eMotor control center (MCC) bus incoming protection\u003c\/li\u003e\n\u003cli\u003eRefinery, chemical plant, and heavy industrial power systems\u003c\/li\u003e\n\u003cli\u003eLarge commercial facility main distribution protection\u003c\/li\u003e\n\u003cli\u003eSub-main breaker in 600V three-phase distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the difference between JJA36250U33X and JJA36250U44X?\u003c\/h3\u003e\u003cp\u003eBoth are Square D 250A, 3-pole, 600V I-Line solid-state MCCBs. The suffix U33X and U44X typically denote different trip unit rating plug configurations, affecting the adjustable current range of the electronic trip unit. Consult Schneider Electric documentation or a qualified electrician to confirm the correct model for your application.\u003c\/p\u003e\u003ch3\u003eWhat is the Square D JJA36250U33X used for?\u003c\/h3\u003e\u003cp\u003eThe JJA36250U33X is used for overcurrent and short-circuit protection of 250-amp feeder and main circuits in three-phase 600V industrial and commercial electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eIs the JJA36250U33X available in new and used condition?\u003c\/h3\u003e\u003cp\u003eYes. Alpha Brokers \u0026amp; Controls stocks the JJA36250U33X in both new and reconditioned\/used condition. All used circuit breakers are tested and inspected prior to sale.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395677565176,"sku":"JJA36250U33X-N","price":6249.0,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":48395677597944,"sku":"JJA36250U33X-U","price":6249.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/CB-SB-JJA36250U33X-1-scaled.jpg?v=1778786549"},{"product_id":"jja36250u44x-square-d-250a-3-pole-600v-iline-solid-state-mccb","title":"Square D - JJA36250U44X 250A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36250U44X\u003c\/strong\u003e is a 3-pole, 250-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, the JJ-frame solid-state trip unit delivers precise, adjustable overcurrent protection for large industrial feeder circuits. Engineered for high-performance three-phase systems where accurate trip coordination and fault current management are critical.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eJJA36250U44X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eJJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolid-state electronic trip unit with adjustable long-time, short-time, and instantaneous settings\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for quick installation in compatible Square D switchboards\u003c\/li\u003e\n\u003cli\u003e250-amp capacity for medium-to-large industrial feeder circuits\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V power systems\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed for NEC compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial feeder circuit protection in switchboards and MCCs\u003c\/li\u003e\n\u003cli\u003eLarge motor control center (MCC) incoming feeds\u003c\/li\u003e\n\u003cli\u003eManufacturing facility sub-panel main protection\u003c\/li\u003e\n\u003cli\u003eData center and critical infrastructure power distribution\u003c\/li\u003e\n\u003cli\u003eProcess control and heavy industrial equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D JJA36250U44X?\u003c\/h3\u003e\u003cp\u003eThe JJA36250U44X is a 250-amp, 3-pole, 600V solid-state I-Line plug-in MCCB from Square D used to protect large feeder and branch circuits in three-phase industrial and commercial electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eHow does the solid-state trip unit differ from thermal magnetic on the JJA36250U44X?\u003c\/h3\u003e\u003cp\u003eUnlike a fixed thermal magnetic trip, the solid-state electronic trip unit on the JJA36250U44X allows engineers to adjust long-time delay, short-time pickup, and instantaneous trip thresholds, enabling precise system coordination and reducing nuisance tripping.\u003c\/p\u003e\u003ch3\u003eWhat is the interrupting capacity of the JJA36250U44X?\u003c\/h3\u003e\u003cp\u003eThe JJA36250U44X is rated at 65kA interrupting capacity at 600V, qualifying it for use in high fault-current industrial environments where large available short-circuit current is present.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395677630712,"sku":"JJA36250U44X-N","price":3299.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/CB-JJA36250U44X-1.webp?v=1778786550"},{"product_id":"lga36600u33x-square-d-600a-3-pole-600v-iline-solid-state-mccb","title":"Square D - LGA36600U33X 600A 3-Pole 600V I-Line Solid State Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D LGA36600U33X\u003c\/strong\u003e is a 3-pole, 600-amp solid-state molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, this heavy-duty LG-frame breaker features an electronic (solid-state) trip unit for highly precise and adjustable protection of large industrial feeder and main circuits. It is ideal for high-capacity three-phase distribution in demanding industrial environments.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLGA36600U33X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eSolid State (Electronic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eLG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSolid-state electronic trip unit enables adjustable long-time, short-time, and instantaneous protection settings\u003c\/li\u003e\n\u003cli\u003eI-Line plug-in mounting for fast installation in Square D LG-frame compatible switchboards\u003c\/li\u003e\n\u003cli\u003e600-amp rating for high-capacity main and feeder circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole design for three-phase 600V industrial power systems\u003c\/li\u003e\n\u003cli\u003eHigh 65kA interrupting rating at 600V for demanding industrial applications\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed and compliant with NEC requirements\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain circuit breaker for large industrial switchboards and MCCs\u003c\/li\u003e\n\u003cli\u003e600A feeder protection in manufacturing plants and process facilities\u003c\/li\u003e\n\u003cli\u003eData center main distribution boards\u003c\/li\u003e\n\u003cli\u003eUtility substations and industrial power distribution systems\u003c\/li\u003e\n\u003cli\u003eMining, oil and gas, and heavy industrial applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D LGA36600U33X?\u003c\/h3\u003e\u003cp\u003eThe Square D LGA36600U33X is a 600-amp, 3-pole, 600V solid-state I-Line plug-in molded case circuit breaker used as a main or feeder breaker in heavy industrial and commercial three-phase electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat does the solid-state trip unit on the LGA36600U33X offer?\u003c\/h3\u003e\u003cp\u003eThe solid-state electronic trip unit provides adjustable long-time delay, short-time delay, and instantaneous trip settings, allowing engineers to precisely coordinate protection with upstream and downstream devices for selective coordination.\u003c\/p\u003e\u003ch3\u003eWhat is the interrupting rating of the LGA36600U33X?\u003c\/h3\u003e\u003cp\u003eThe LGA36600U33X is rated at 65kA interrupting capacity at 600V, making it suitable for high fault-current industrial distribution systems where high available fault current is present.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395679727864,"sku":"LGA36600U33X-N","price":3299.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/LGA36600U33X-1.jpg?v=1778786584"},{"product_id":"hda36100-square-d-100a-3-pole-600v-iline-mccb","title":"Square D - HDA36100 100A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HDA36100\u003c\/strong\u003e is a 3-pole, 100-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC with I-Line plug-in mounting. Manufactured by Schneider Electric, the HD series delivers dependable branch-circuit and feeder protection for industrial and commercial three-phase power systems. The I-Line plug-in interface simplifies installation and replacement within compatible Square D switchboards and panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHDA36100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting enables tool-free installation in Square D I-Line equipment\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip mechanism for overload and instantaneous fault protection\u003c\/li\u003e\n\u003cli\u003e100-amp rating ideal for mid-range industrial feeder and branch circuits\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 600V distribution systems\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed in compliance with NEC requirements\u003c\/li\u003e\n\u003cli\u003eSupports field-installable accessories for expanded functionality\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial and commercial 600V three-phase panelboards\u003c\/li\u003e\n\u003cli\u003e100A motor and equipment feeder circuit protection\u003c\/li\u003e\n\u003cli\u003eSwitchboard branch circuits in manufacturing facilities\u003c\/li\u003e\n\u003cli\u003eData centers and large commercial building electrical systems\u003c\/li\u003e\n\u003cli\u003eUtility and process control equipment protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HDA36100 used for?\u003c\/h3\u003e\u003cp\u003eThe Square D HDA36100 is a 100-amp, 3-pole, 600V thermal magnetic I-Line plug-in MCCB used to protect feeder and branch circuits in commercial and industrial three-phase 600V electrical distribution systems.\u003c\/p\u003e\u003ch3\u003eIs the HDA36100 compatible with Square D I-Line panelboards?\u003c\/h3\u003e\u003cp\u003eYes. The HDA36100 features I-Line plug-in mounting, making it directly compatible with Square D I-Line panelboards and switchboards rated for HD-frame breakers. Verify bus ampacity and frame compatibility before installation.\u003c\/p\u003e\u003ch3\u003eWhat does the thermal magnetic trip type mean for the HDA36100?\u003c\/h3\u003e\u003cp\u003eThermal magnetic means the breaker uses a bimetallic strip for overload (time-delay) protection and an electromagnetic mechanism for instantaneous short-circuit interruption, providing dual-mode overcurrent protection in a single device.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395704271096,"sku":"HDA36100-N","price":586.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HDA36100-1.jpg?v=1778786982"},{"product_id":"hla36070-square-d-70a-3-pole-600v-iline-mccb","title":"Square D HLA36070 70A 3-Pole 600V I-Line Plug-In Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D HLA36070\u003c\/strong\u003e is a 3-pole, 70-amp thermal magnetic molded case circuit breaker (MCCB) rated for 600VAC systems with I-Line plug-in mounting. Part of the Schneider Electric HL series, it is engineered for reliable overcurrent protection in industrial and commercial three-phase distribution panels. The I-Line plug-in design allows fast, tool-free installation into compatible Square D I-Line panelboards.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHLA36070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eHL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eI-Line plug-in mounting for quick installation and removal in Square D I-Line panelboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for precise overload and instantaneous short-circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole design for balanced three-phase 600V distribution\u003c\/li\u003e\n\u003cli\u003eHigh interrupting capacity suitable for industrial environments\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed for compliance with NEC requirements\u003c\/li\u003e\n\u003cli\u003eCompatible with Square D I-Line accessory kit options\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial 600V three-phase distribution panels\u003c\/li\u003e\n\u003cli\u003eMotor feeder and branch circuit protection up to 70A\u003c\/li\u003e\n\u003cli\u003eManufacturing plants and process equipment panels\u003c\/li\u003e\n\u003cli\u003eCommercial buildings with 600VAC service\u003c\/li\u003e\n\u003cli\u003eOil and gas, mining, and utility distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Square D HLA36070 circuit breaker?\u003c\/h3\u003e\u003cp\u003eThe Square D HLA36070 is a 70-amp, 3-pole, 600V I-Line plug-in thermal magnetic molded case circuit breaker used for overcurrent and short-circuit protection in industrial and commercial three-phase 600V power distribution systems.\u003c\/p\u003e\u003ch3\u003eWhat panelboards are compatible with the HLA36070?\u003c\/h3\u003e\u003cp\u003eThe HLA36070 uses I-Line plug-in mounting and is compatible with Square D I-Line panelboards and switchboards designed to accept HL-frame breakers. Always verify frame size and bus compatibility before installation.\u003c\/p\u003e\u003ch3\u003eWhat is the interrupting rating of the Square D HLA36070?\u003c\/h3\u003e\u003cp\u003eThe HLA36070 has an interrupting rating of 65kA at 240V and 25kA at 600V, suitable for demanding industrial power distribution applications.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395707384056,"sku":"HLA36070-N","price":949.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/square-d-hga36060u31x-3-pole-60-amp-600v-circuit-breaker-front-600_5c1a5b1e-cbd7-4b53-97b9-9604c0c92e8b.jpg?v=1778787042"},{"product_id":"ed43b045-siemens-45a-3-pole-480v-bolt-on-mccb","title":"Siemens ED43B045 45A 3-Pole 480V Bolt-On Molded Case Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens ED43B045\u003c\/strong\u003e is a 3-pole, 45-amp thermal magnetic molded case circuit breaker (MCCB) rated for 480VAC systems. Designed for bolt-on panelboard installation, it provides reliable overcurrent and short-circuit protection for commercial and industrial three-phase electrical distribution systems. The ED4 series is trusted by electricians and facilities engineers for its compact footprint, consistent trip performance, and UL 489 listing.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eED43B045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Rating\u003c\/td\u003e\n\u003ctd\u003e45A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e480VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Type\u003c\/td\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd\u003e65kA @ 240V \/ 25kA @ 480V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eUL 489 Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003eED4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThermal magnetic trip mechanism provides accurate overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eBolt-on design for secure, vibration-resistant mounting in panelboards\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for three-phase 480V power distribution\u003c\/li\u003e\n\u003cli\u003eCompact ED4 frame fits standard Siemens and compatible load centers\u003c\/li\u003e\n\u003cli\u003eUL 489 Listed — meets National Electrical Code (NEC) requirements\u003c\/li\u003e\n\u003cli\u003eField-installable accessories including shunt trip, aux contacts, and locking devices\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCommercial and industrial 480V panelboards and load centers\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection up to 45A\u003c\/li\u003e\n\u003cli\u003eHVAC equipment feeders and branch circuits\u003c\/li\u003e\n\u003cli\u003eManufacturing facility power distribution panels\u003c\/li\u003e\n\u003cli\u003eMain or branch breaker in 480V three-phase systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003ch3\u003eWhat is the Siemens ED43B045 circuit breaker used for?\u003c\/h3\u003e\u003cp\u003eThe Siemens ED43B045 is a 45-amp, 3-pole, 480V bolt-on molded case circuit breaker used to protect three-phase branch circuits and feeder circuits in commercial and industrial panelboards. It safeguards wiring and equipment against overloads and short circuits.\u003c\/p\u003e\u003ch3\u003eWhat is the interrupting rating of the ED43B045?\u003c\/h3\u003e\u003cp\u003eThe Siemens ED43B045 has an interrupting rating of 65kA at 240V and 25kA at 480V, making it suitable for most commercial and light industrial 480V distribution applications.\u003c\/p\u003e\u003ch3\u003eIs the ED43B045 compatible with Siemens panelboards?\u003c\/h3\u003e\u003cp\u003eYes. The ED43B045 uses a bolt-on mounting style compatible with Siemens S-series and P-series panelboards. Always verify compatibility with your specific panel model before installation.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395743297784,"sku":"ED43B045-N","price":197.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/ED43B045L_Illustration_Front_Original.jpg?v=1778787594"},{"product_id":"lgb3b050b-siemens-molded-case-circuit-breaker-bolt-on-50-amp-3-pole-600-volt","title":"Siemens LGB3B050B — 50A 3-Pole 600V Bolt-On Molded Case Circuit Breaker (MCCB)","description":"\u003cp\u003eThe \u003cstrong\u003eSiemens LGB3B050B\u003c\/strong\u003e is a 50-amp, 3-pole, 600V thermal magnetic molded case circuit breaker (MCCB) with bolt-on mounting. Part of Siemens' LGB frame series, this breaker provides reliable three-phase overcurrent protection for industrial and commercial distribution systems requiring robust performance at up to 600VAC.\u003c\/p\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e LGB3B050B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Siemens\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-Pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame:\u003c\/strong\u003e LGB Frame\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Type:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e UL Listed, CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBolt-on mounting for a secure, vibration-resistant installation in Siemens panelboard enclosures\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip provides accurate overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for complete three-phase protection at 600VAC\u003c\/li\u003e\n\u003cli\u003eLGB frame construction engineered for reliable performance in industrial environments\u003c\/li\u003e\n\u003cli\u003eSiemens quality manufacturing for long service life and consistent trip accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\u003cp\u003eThe LGB3B050B is used as a feeder or branch circuit breaker in industrial plants, manufacturing facilities, and commercial buildings requiring 50A three-phase overcurrent protection at 600V in bolt-on panelboard configurations.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"New","offer_id":48395750342904,"sku":"LGB3B050B-N","price":187.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260212_224322.jpg?v=1778787718"},{"product_id":"sela36at0060-ge-molded-case-circuit-breaker-bolt-on-60-amp-3-pole-600-volt","title":"GE SELA36AT0060 — 60A 3-Pole 600V 100kA Bolt-On Molded Case Circuit Breaker (MCCB)","description":"\u003cp\u003eThe \u003cstrong\u003eGE SELA36AT0060\u003c\/strong\u003e is a 60-amp, 3-pole, 600V molded case circuit breaker (MCCB) with bolt-on mounting from General Electric's SE-series frame. Featuring a high 100kA interrupting capacity at 240VAC, this breaker is engineered for robust short-circuit and overload protection in demanding commercial and industrial distribution systems.\u003c\/p\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e SELA36AT0060\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE \/ General Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 60A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-Pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Capacity:\u003c\/strong\u003e 100kA @ 240VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame:\u003c\/strong\u003e SE Type Frame\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Bolt-On\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Type:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e UL Listed, CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e100kA interrupting capacity at 240VAC for high fault-current commercial and industrial applications\u003c\/li\u003e\n\u003cli\u003eBolt-on mounting provides a secure, vibration-resistant connection in panelboard enclosures\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip for precise overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e3-pole configuration for simultaneous three-phase circuit protection at 600V\u003c\/li\u003e\n\u003cli\u003eGE SE-type frame known for reliability in switchboard and distribution panel applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\u003cp\u003eThe SELA36AT0060 is used as a feeder or branch breaker in commercial buildings, industrial facilities, and large-scale distribution systems requiring high-interrupting-capacity 60A, 600VAC three-phase overcurrent protection.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Used","offer_id":48395796316408,"sku":"SELA36AT0060-U","price":359.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260203_124530.jpg?v=1778788432"},{"product_id":"hmcp007c0c-eaton-molded-case-circuit-breaker-feed-thru-7-amp-3-pole-600-volt","title":"Eaton HMCP007C0C — 7A 3-Pole 600V Motor Circuit Protector (Magnetic-Only MCCB Circuit Breaker)","description":"\u003cp\u003eThe \u003cstrong\u003eEaton HMCP007C0C\u003c\/strong\u003e is a 7-amp, 3-pole, 600VAC \/ 250VDC magnetic-only molded case circuit breaker (MCCB) with Feed-Thru mounting. Part of Eaton's HMCP (Heinemann Motor Circuit Protector) series, this breaker is specifically engineered for motor branch circuit protection, providing instantaneous magnetic-only trip to withstand motor inrush currents without nuisance tripping.\u003c\/p\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e HMCP007C0C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Eaton \/ Cutler-Hammer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 7A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-Pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600VAC \/ 250VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e HMCP (Motor Circuit Protector)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Feed-Thru\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Type:\u003c\/strong\u003e Magnetic Only (Instantaneous)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e UL Listed, CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMagnetic-only trip tolerates high motor inrush currents without nuisance tripping\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for motor branch circuit protection per NEC 430 requirements\u003c\/li\u003e\n\u003cli\u003eAdjustable instantaneous trip setting to coordinate with motor starting characteristics\u003c\/li\u003e\n\u003cli\u003e3-pole design for complete three-phase motor protection at 600VAC or 250VDC\u003c\/li\u003e\n\u003cli\u003eFeed-thru mounting for use in motor control centers and industrial panelboards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\u003cp\u003eThe HMCP007C0C is used to protect three-phase motors up to 7A in motor control centers (MCCs), industrial control panels, and manufacturing equipment requiring NEC-compliant motor branch circuit protection at 600VAC.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48395846353144,"sku":"HMCP007C0C-N","price":414.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/Photoroom_20260208_222227.jpg?v=1778789215"},{"product_id":"square-d-rc3040m200sl-test-block-bypass-meter-sockets","title":"Square D - RC3040M200SL Test Block Bypass Meter Socket | 200A Ringless NEMA 3R","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D RC3040M200SL\u003c\/strong\u003e is a \u003cstrong\u003e200-amp test block bypass meter socket\u003c\/strong\u003e featuring a ringless cover design, NEMA 3R enclosure, and 120\/240V single-phase, 3-wire configuration. Designed for utility-grade metering applications where test block functionality and bypass capability are required, this unit is UL listed and surface-mount ready.\u003c\/p\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e RC3040M200SL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Square D \/ Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Test Block Bypass Meter Socket\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 200 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCircuit:\u003c\/strong\u003e 1-Phase, 3-Wire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e NEMA 3R (Outdoor Rated)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover Type:\u003c\/strong\u003e Ringless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Surface Mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListing:\u003c\/strong\u003e UL Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe RC3040M200SL is engineered for commercial and utility metering installations where test block access and bypass switching are essential for meter maintenance without interrupting service to the customer. The integrated test block allows utility technicians to test, maintain, and replace the revenue meter safely while maintaining continuity of electrical service.\u003c\/p\u003e\n\u003cp\u003eThe ringless cover design is widely required by utilities across North America, eliminating the need for a meter ring and providing tamper-resistant access control. The NEMA 3R enclosure ensures reliable performance in outdoor installations, resisting rain, sleet, and ice formation. Surface mounting simplifies installation on building facades, meter pedestals, and service panels.\u003c\/p\u003e\n\u003ch2\u003eWhy Choose the Square D RC3040M200SL?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest block bypass enables meter maintenance without service interruption\u003c\/li\u003e\n\u003cli\u003eRingless design meets utility requirements across major North American service territories\u003c\/li\u003e\n\u003cli\u003eNEMA 3R rated for outdoor durability in all weather conditions\u003c\/li\u003e\n\u003cli\u003e200A capacity handles large residential and small commercial loads\u003c\/li\u003e\n\u003cli\u003eUL listed for code-compliant installations\u003c\/li\u003e\n\u003cli\u003eSquare D brand trusted by utilities and electrical contractors nationwide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUtility-grade commercial metering stations\u003c\/li\u003e\n\u003cli\u003eLarge residential service entrances with bypass requirements\u003c\/li\u003e\n\u003cli\u003eMunicipal and cooperative utility metering infrastructure\u003c\/li\u003e\n\u003cli\u003eService entrances requiring test block access for meter calibration\u003c\/li\u003e\n\u003cli\u003eCommercial buildings with utility-mandated bypass meter sockets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is a test block bypass meter socket?\u003c\/strong\u003e\u003cbr\u003eA test block bypass meter socket includes an integrated switching mechanism that allows the utility to bypass the revenue meter during testing or replacement, maintaining uninterrupted electrical service to the customer while the meter is being serviced.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does \"ringless\" mean on a meter socket?\u003c\/strong\u003e\u003cbr\u003eRingless refers to the cover design — instead of a separate locking ring holding the meter in place, a ringless socket uses a cover that latches over the meter jaw assembly. Many utilities require ringless sockets as they provide better tamper resistance and access control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is NEMA 3R?\u003c\/strong\u003e\u003cbr\u003eNEMA 3R is an enclosure rating that indicates the unit is suitable for outdoor installation, providing protection against rain, sleet, and ice without compromising equipment operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the RC3040M200SL available new or used?\u003c\/strong\u003e\u003cbr\u003eThe RC3040M200SL is available in both New and Used condition. Contact us for current availability and pricing on each condition tier.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395849466104,"sku":"RC3040M200SL-N","price":4900.0,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":48395849498872,"sku":"RC3040M200SL-U","price":4900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/RC3040M200SL.png?v=1779886818"},{"product_id":"square-d-rc3040m150sl-test-block-bypass-meter-sockets","title":"Square D - RC3040M150SL Test Block Bypass Meter Socket | 150A Ringless NEMA 3R","description":"\u003ch2\u003eSquare D RC3040M150SL — Test Block Bypass Single Meter Socket, 150A, NEMA 3R, Ringless\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSquare D RC3040M150SL\u003c\/strong\u003e is a \u003cstrong\u003e150-amp test block bypass meter socket\u003c\/strong\u003e featuring a ringless cover, NEMA 3R outdoor-rated enclosure, and 120\/240V single-phase, 3-wire configuration. Purpose-built for utility and commercial metering installations requiring safe meter bypass capability, this UL-listed unit is engineered for reliable long-term outdoor service.\u003c\/p\u003e\n\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e RC3040M150SL\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Square D \/ Schneider Electric\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Test Block Bypass Meter Socket\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 150 Amps\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120\/240 VAC\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCircuit:\u003c\/strong\u003e 1-Phase, 3-Wire\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e NEMA 3R (Outdoor Rated)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCover Type:\u003c\/strong\u003e Ringless\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Surface Mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eListing:\u003c\/strong\u003e UL Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe RC3040M150SL delivers the same trusted test block bypass platform as the RC3040M series at a \u003cstrong\u003e150-amp rating\u003c\/strong\u003e, making it the right choice for residential and light commercial service entrances where bypass metering is a utility requirement but full 200A capacity isn't needed.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated test block allows utility crews to safely test, calibrate, or replace the revenue meter without interrupting electrical service — a critical capability for utilities committed to uptime and customer satisfaction. The ringless cover ensures tamper-resistant meter access and is accepted by major utilities across North America. NEMA 3R construction makes the RC3040M150SL weather-resistant and reliable in outdoor environments year-round.\u003c\/p\u003e\n\n\u003ch2\u003eWhy Choose the Square D RC3040M150SL?\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eTest block bypass allows live meter replacement without service interruption\u003c\/li\u003e\n  \u003cli\u003e150A rating optimized for residential and light commercial service entrances\u003c\/li\u003e\n  \u003cli\u003eRingless cover — tamper-resistant and widely utility-accepted\u003c\/li\u003e\n  \u003cli\u003eNEMA 3R outdoor enclosure withstands rain, sleet, and ice\u003c\/li\u003e\n  \u003cli\u003eUL listed for NEC-compliant installation\u003c\/li\u003e\n  \u003cli\u003eSurface mount design for straightforward field installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Compares: RC3040M150SL vs RC3040M200SL\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRC3040M150SL:\u003c\/strong\u003e 150A — Residential and light commercial service entrances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRC3040M200SL:\u003c\/strong\u003e 200A — Larger residential and small commercial applications\u003c\/li\u003e\n  \u003cli\u003eBoth feature ringless covers, NEMA 3R enclosures, test block bypass, and UL listing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eResidential service entrances with utility bypass requirements\u003c\/li\u003e\n  \u003cli\u003eLight commercial metering installations\u003c\/li\u003e\n  \u003cli\u003eUtility infrastructure upgrades requiring test block access\u003c\/li\u003e\n  \u003cli\u003eMunicipal and cooperative utility metering programs\u003c\/li\u003e\n  \u003cli\u003eNew construction where utility-specified bypass sockets are required\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is a test block bypass meter socket?\u003c\/strong\u003e\u003cbr\u003eA test block bypass meter socket integrates a switching mechanism that allows a utility technician to safely bypass the revenue meter during testing, calibration, or replacement — without cutting power to the customer. This is required by many utilities to enable safe meter maintenance on live circuits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the RC3040M150SL and RC3040M200SL?\u003c\/strong\u003e\u003cbr\u003eThe primary difference is amperage: the RC3040M150SL is rated at 150 amps, while the RC3040M200SL is rated at 200 amps. Both share the same ringless design, NEMA 3R enclosure, test block bypass functionality, and UL listing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat does \"ringless\" mean on a meter socket?\u003c\/strong\u003e\u003cbr\u003eA ringless meter socket uses an integrated cover latch rather than a separate locking ring to secure the utility meter. This design is preferred by many utilities for its tamper-resistance and simpler field operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the RC3040M150SL available new or used?\u003c\/strong\u003e\u003cbr\u003eThe RC3040M150SL is available in both New and Used condition. Contact us to confirm current stock and pricing for each condition.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395850580216,"sku":"RC3040M150SL-N","price":4900.0,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":48395850612984,"sku":"RC3040M150SL-U","price":4900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/RC3040M150SL.png?v=1779907665"},{"product_id":"jja36150-square-d-molded-case-circuit-breaker-i-line-plug-in-150-amp-3-pole-600-volt","title":"Square D JJA36150 — 150A 3-Pole 600V I-Line Plug-In Molded Case Circuit Breaker (MCCB)","description":"\u003cp\u003eThe \u003cstrong\u003eSquare D JJA36150\u003c\/strong\u003e is a 150-amp, 3-pole, 600V thermal magnetic molded case circuit breaker (MCCB) with I-Line Plug-In mounting. Part of Schneider Electric's JJ frame series, this breaker delivers dependable three-phase overcurrent protection for industrial switchboards, commercial distribution panels, and main feeder applications at up to 600VAC.\u003c\/p\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e JJA36150\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Square D \/ Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 150A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoles:\u003c\/strong\u003e 3-Pole\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 600VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame:\u003c\/strong\u003e JJ Frame (J Frame)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e I-Line Plug-In\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrip Type:\u003c\/strong\u003e Thermal Magnetic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e UL Listed, CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eI-Line Plug-In mounting for efficient, safe installation in Square D I-Line panelboards and switchboards\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip mechanism for accurate overload and short-circuit protection at 150A\u003c\/li\u003e\n\u003cli\u003e3-pole configuration provides simultaneous protection across all three phases at 600V\u003c\/li\u003e\n\u003cli\u003eJJ frame design built for reliable performance in demanding industrial environments\u003c\/li\u003e\n\u003cli\u003eSchneider Electric engineering quality for consistent, long-term operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCommon Applications\u003c\/h2\u003e\n\u003cp\u003eThe JJA36150 serves as a main or feeder circuit breaker in industrial facilities, commercial buildings, and large distribution panels operating at 600VAC and requiring 150A three-phase overcurrent protection in I-Line switchboard configurations.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395859263736,"sku":"JJA36150-N","price":1102.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/JJA36150-New-1_f6896d4f-c09d-4009-aec6-32efba268583.jpg?v=1778789412"}],"url":"https:\/\/alphabreakersandcontrols.com\/collections\/optimized.oembed?page=4","provider":"Alpha Breakers \u0026 Controls","version":"1.0","type":"link"}