{"product_id":"ccvh2100x-circuit-breaker-240v-100a-2p-25ka240v-feed-thru-tenant-main","title":"Eaton CCVH2100X – 100A 2-Pole 240V Feed-Thru Tenant Main Circuit Breaker","description":"\u003cp\u003eThe \u003cstrong\u003eEaton CCVH2100X\u003c\/strong\u003e is a 2-pole, 100-amp thermal magnetic molded case circuit breaker rated for 120\/240V with an interrupting capacity of \u003cstrong\u003e25kA @ 240V\u003c\/strong\u003e. Designed for \u003cstrong\u003eFeed-Thru Tenant Main\u003c\/strong\u003e applications, it delivers reliable overcurrent and short-circuit protection in multi-tenant residential and light commercial panels.\u003c\/p\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCCVH2100X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kA @ 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries \/ Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCCVH Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 489, CSA C22.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e25kA @ 240V interrupting capacity\u003c\/strong\u003e — handles high fault currents without nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal magnetic trip mechanism\u003c\/strong\u003e — precise overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFeed-Thru Tenant Main configuration\u003c\/strong\u003e — conductors pass through for downstream tenant connections\u003c\/li\u003e\n\u003cli\u003eUL 489 listed and CSA C22.2 certified for full North American code compliance\u003c\/li\u003e\n\u003cli\u003eIdeal for apartment buildings, condominiums, and multi-unit commercial properties\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe CCVH Series is Eaton's purpose-built platform for tenant metering centers and multi-family residential distribution. The Feed-Thru design allows service conductors to pass through the breaker to individual tenant meters, making installation fast and code-compliant.\u003c\/p\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-tenant residential metering centers and load centers\u003c\/li\u003e\n\u003cli\u003eApartment building and condominium electrical distribution\u003c\/li\u003e\n\u003cli\u003eLight commercial multi-unit service entrance equipment\u003c\/li\u003e\n\u003cli\u003e120\/240V panelboards requiring tenant main protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the interrupting capacity of the CCVH2100X?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The CCVH2100X has an interrupting capacity of 25kA at 240V, suitable for systems with moderate available fault currents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the Feed-Thru Tenant Main mounting configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Feed-Thru means conductors pass through the breaker body to downstream terminals, allowing this breaker to serve as the main disconnect for individual tenant meters in a metering stack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CCVH2100X UL listed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is UL 489 listed and CSA C22.2 certified for use in North American electrical systems.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48396205850872,"sku":"CCVH2100X-N","price":414.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/CCVH2100-new-1_21519d5c-2117-4bc8-bc1d-864ec51580bb.jpg?v=1778795129","url":"https:\/\/alphabreakersandcontrols.com\/products\/ccvh2100x-circuit-breaker-240v-100a-2p-25ka240v-feed-thru-tenant-main","provider":"Alpha Breakers \u0026 Controls","version":"1.0","type":"link"}