{"product_id":"eaton-pdg23m0035tffl-power-defense-35a-3-pole-600v-molded-case-circuit-breaker-feed-thru","title":"Eaton PDG23M0035TFFL Power Defense 35A 3-Pole 600V Molded Case Circuit Breaker | Feed-Thru","description":"\u003ch2\u003eEaton PDG23M0035TFFL — Power Defense Molded Case Circuit Breaker, 35A, 3-Pole, 600V, Feed-Thru\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eEaton PDG23M0035TFFL\u003c\/strong\u003e is a high-performance \u003cstrong\u003e35-amp, 3-pole, 600V molded case circuit breaker\u003c\/strong\u003e from Eaton's globally rated \u003cstrong\u003ePower Defense (PD2) Frame 2\u003c\/strong\u003e platform. Engineered for demanding commercial and industrial power distribution systems, this breaker delivers superior fault protection with a \u003cstrong\u003e65 kAIC interrupting capacity at 480V\u003c\/strong\u003e — making it one of the highest-rated breakers in its class.\u003c\/p\u003e\n\n\u003cp\u003eConfigured with \u003cstrong\u003eFeed-Thru (load-only) standard terminals\u003c\/strong\u003e and a \u003cstrong\u003efixed thermal-magnetic (T-M) trip unit\u003c\/strong\u003e, the PDG23M0035TFFL is designed for reliable overload and short-circuit protection in panelboards and switchboards. It is a direct replacement for the legacy \u003cstrong\u003eHFD3035\u003c\/strong\u003e and compatible Eaton Frame 2 applications, reducing downtime during upgrades.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e35A continuous current rating\u003c\/strong\u003e — ideal for branch circuit and feeder protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3-Pole, 600V AC\u003c\/strong\u003e — suitable for 3-phase commercial and industrial systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e65 kAIC @ 480V (UL)\u003c\/strong\u003e — industry-leading interrupting capacity for its frame size\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFixed Thermal-Magnetic Trip Unit\u003c\/strong\u003e — reliable, non-adjustable overload and short-circuit protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeed-Thru Configuration (Load-Only Terminals)\u003c\/strong\u003e — designed for downstream connection in panelboards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Defense Frame 2 platform\u003c\/strong\u003e — globally rated for UL, IEC, CSA, and CCC standards\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect replacement for HFD3035\u003c\/strong\u003e — backward-compatible for easy upgrades\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor\u003c\/strong\u003e — 88.9mm (D) × 152.4mm (H) × 104.6mm (W)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePDG23M0035TFFL\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Defense (PD2 Global)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame 2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupting Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 kAIC @ 480V | 18 kAIC @ 600V (UL\/CSA)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Thermal-Magnetic (T-M, Fxd-Fxd)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru — Standard Load-Only Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Breaker Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 489, CSA, IEC 60947-2, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (D × H × W)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88.9mm × 152.4mm × 104.6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.82 kg (4.01 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLegacy Replacement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHFD3035\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat Is a Feed-Thru Molded Case Circuit Breaker?\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003efeed-thru (or feed-through) circuit breaker\u003c\/strong\u003e is configured with load-side terminals only. Power is fed into the breaker from the bus bars of the panelboard or switchboard, and the breaker connects on the load side. This design is standard in distribution panels where the breaker is mounted directly into a pre-wired bus assembly, simplifying installation and ensuring a clean, organized wiring layout.\u003c\/p\u003e\n\n\u003ch3\u003eWhy Choose the Eaton Power Defense Platform?\u003c\/h3\u003e\n\u003cp\u003eEaton's \u003cstrong\u003ePower Defense series\u003c\/strong\u003e is a globally rated molded case circuit breaker platform designed to meet UL, IEC, CSA, and CCC standards within a single product. This means fewer SKUs to manage across international projects, simplified procurement, and consistent protection performance. The Frame 2 platform is engineered for high fault-current environments, making it a trusted choice for commercial buildings, industrial facilities, data centers, and utility applications.\u003c\/p\u003e\n\n\u003ch3\u003eCompatible Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCommercial and industrial panelboards\u003c\/li\u003e\n  \u003cli\u003eMotor control centers (MCC)\u003c\/li\u003e\n  \u003cli\u003eSwitchboards and switchgear\u003c\/li\u003e\n  \u003cli\u003eDistribution panels in 480V 3-phase systems\u003c\/li\u003e\n  \u003cli\u003eUpgrade or replacement for legacy Eaton HFD3035 breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat does PDG23M0035TFFL replace?\u003c\/strong\u003e\u003cbr\u003eThe PDG23M0035TFFL is a direct replacement for the Eaton \u003cstrong\u003eHFD3035\u003c\/strong\u003e and other compatible Frame 2 breakers. It fits the same panelboard footprint, making it an easy drop-in upgrade.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the interrupting rating of the PDG23M0035TFFL?\u003c\/strong\u003e\u003cbr\u003eThis breaker carries a \u003cstrong\u003e65 kAIC interrupting capacity at 480V\u003c\/strong\u003e (UL rated), and 18 kAIC at 600V. This high interrupt rating makes it suitable for installations with high available fault current.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the PDG23M0035TFFL UL listed?\u003c\/strong\u003e\u003cbr\u003eYes. The PDG23M0035TFFL is certified to \u003cstrong\u003eUL 489\u003c\/strong\u003e, as well as CSA, IEC 60947-2, and CCC — making it globally compliant for commercial and industrial use.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between PDG23M0035TFFL and PDG23M0035TFFJ?\u003c\/strong\u003e\u003cbr\u003eThe primary difference is the terminal configuration. The \u003cstrong\u003eTFFL\u003c\/strong\u003e variant uses \u003cstrong\u003efeed-thru (load-only) terminals\u003c\/strong\u003e, while the \u003cstrong\u003eTFFJ\u003c\/strong\u003e variant includes \u003cstrong\u003estandard line and load terminals\u003c\/strong\u003e for direct wiring on both sides.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat does the \"M\" designation mean in PDG23M0035TFFL?\u003c\/strong\u003e\u003cbr\u003eIn Eaton's Power Defense catalog numbering, the \u003cstrong\u003e\"M\" denotes the higher interrupt rating variant\u003c\/strong\u003e — specifically 65 kAIC at 480V, compared to the \"G\" variant which is rated at 35 kAIC at 480V.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"New","offer_id":48396210274552,"sku":"PDG23M0035TFFL-N","price":575.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/PDG23M0035TFFJ-All-New-1_1a2ee698-76f2-40fa-9a71-33abf349c7d3.jpg?v=1778795244","url":"https:\/\/alphabreakersandcontrols.com\/products\/eaton-pdg23m0035tffl-power-defense-35a-3-pole-600v-molded-case-circuit-breaker-feed-thru","provider":"Alpha Breakers \u0026 Controls","version":"1.0","type":"link"}