{"product_id":"eaton-pdg23m0060tffl-60a-3-pole-600v-feed-thru-mccb","title":"Eaton PDG23M0060TFFL 60A 3-Pole 600V Feed-Thru Molded Case Circuit Breaker","description":"Eaton PDG23M0060TFFL — 60 Amp, 3-Pole, 600V Feed-Thru Molded Case Circuit Breaker\n\n\u003cp\u003eThe \u003cstrong\u003eEaton PDG23M0060TFFL\u003c\/strong\u003e is a heavy-duty, thermal-magnetic \u003cstrong\u003emolded case circuit breaker (MCCB)\u003c\/strong\u003e engineered for reliable overcurrent and short-circuit protection in demanding industrial and commercial power distribution systems. With a \u003cstrong\u003e60-amp continuous current rating\u003c\/strong\u003e, \u003cstrong\u003e3-pole configuration\u003c\/strong\u003e, and \u003cstrong\u003e600VAC voltage rating\u003c\/strong\u003e, this breaker delivers the performance and safety compliance required for three-phase panel boards, switchgear, and distribution equipment.\u003c\/p\u003e\n\n\u003cp\u003eThe Feed-Thru (TFFL) terminal design allows for flexible wiring configurations, making installation efficient and code-compliant in both new construction and retrofit applications.\u003c\/p\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003ePDG23M0060TFFL\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e60 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTrip Mechanism\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru (TFFL)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eFrame Series\u003c\/td\u003e\n\u003ctd\u003ePDG \/ G-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFeatures \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal-Magnetic Trip Technology:\u003c\/strong\u003e Provides dual-level protection — thermal element guards against sustained overloads, while the magnetic element responds instantly to short-circuit faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeed-Thru Terminal Design:\u003c\/strong\u003e Enables pass-through wiring for simplified bus connections, reducing installation time and improving panel layout efficiency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e600V Rating:\u003c\/strong\u003e Suitable for standard three-phase commercial and industrial power systems across North America.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e3-Pole Configuration:\u003c\/strong\u003e Ideal for three-phase load protection — motors, HVAC equipment, compressors, and distribution panels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEaton G-Frame Platform:\u003c\/strong\u003e Built on Eaton's proven G-Frame series, known for consistent interrupt ratings and long service life.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL Listed:\u003c\/strong\u003e Meets NEC requirements and is suitable for use in UL-labeled assemblies and listed switchgear.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial motor control centers (MCCs)\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial panelboards\u003c\/li\u003e\n  \u003cli\u003eThree-phase power distribution equipment\u003c\/li\u003e\n  \u003cli\u003eHVAC and mechanical systems\u003c\/li\u003e\n  \u003cli\u003eManufacturing and process control environments\u003c\/li\u003e\n  \u003cli\u003eRetrofit and replacement in existing Eaton G-Frame installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Choose the Eaton PDG23M0060TFFL?\u003c\/h3\u003e\n\u003cp\u003eEaton is a globally recognized leader in electrical protection and power management. The PDG series molded case circuit breakers are trusted by electrical contractors, engineers, and facility managers for their durability, precise trip characteristics, and compatibility with Eaton's broad ecosystem of panelboards and switchgear. The \u003cstrong\u003ePDG23M0060TFFL\u003c\/strong\u003e is a direct, drop-in solution for 60A, 3-pole, 600V Feed-Thru applications — eliminating costly custom fabrication or field modifications.\u003c\/p\u003e\n\n\u003cp\u003eThis unit is available in \u003cstrong\u003enew condition\u003c\/strong\u003e and ships ready for immediate installation.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat does \"Feed-Thru\" (TFFL) mean on a circuit breaker?\u003c\/strong\u003e\u003cbr\u003e\nFeed-Thru terminals allow conductors to pass through the breaker's terminal block, connecting to both the incoming and outgoing sides. This simplifies panel wiring, especially in applications where a single cable must feed multiple devices.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the PDG23M0060TFFL compatible with Eaton panelboards?\u003c\/strong\u003e\u003cbr\u003e\nYes. This breaker is designed for use with Eaton's G-Frame compatible panelboards and switchgear. Always verify frame compatibility with your specific panel model before installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between a thermal-magnetic and electronic trip breaker?\u003c\/strong\u003e\u003cbr\u003e\nThermal-magnetic breakers use bimetallic strips (for overload protection) and magnetic coils (for short-circuit protection). They are cost-effective, maintenance-free, and well-suited for standard applications. Electronic trip breakers offer adjustable settings and are typically used in higher-frame or more complex distribution systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat voltage systems is this breaker rated for?\u003c\/strong\u003e\u003cbr\u003e\nThe PDG23M0060TFFL is rated for 600VAC, covering 480V and 600V three-phase systems commonly used in North American commercial and industrial facilities.\u003c\/p\u003e\n]]\u0026gt;","brand":"Eaton","offers":[{"title":"New","offer_id":48396208963832,"sku":"PDG23M0060TFFL-N","price":535.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/PDG23M0060TFFJ-New-1_562967de-f076-481d-9330-97123e77af11.jpg?v=1778795216","url":"https:\/\/alphabreakersandcontrols.com\/products\/eaton-pdg23m0060tffl-60a-3-pole-600v-feed-thru-mccb","provider":"Alpha Breakers \u0026 Controls","version":"1.0","type":"link"}