{"product_id":"jda36200-square-d-molded-case-circuit-breaker-i-line-plug-in-200-amp-3-pole-600-volt","title":"JDA36200 - Square D - Molded Case Circuit Breaker I-Line Plug-In - 200 Amp - 3 Pole - 600 Volt","description":"\u003cp\u003e\u003cstrong\u003eThe Square D JDA36200 is a 200 Amp, 3-pole, 600 Volt molded case circuit breaker\u003c\/strong\u003e built for I-Line plug-in mounting in Square D panelboards and switchboards. It uses thermal-magnetic trip technology for reliable overcurrent protection and serves as the direct replacement for the discontinued KA36200, making it a drop-in upgrade for existing I-Line distribution equipment.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e200A rated, 3-pole, 3-phase molded case circuit breaker\u003c\/li\u003e\n\u003cli\u003eVoltage rated 240VAC, 480VAC, 600VAC, and 250VDC\u003c\/li\u003e\n\u003cli\u003eThermal-magnetic trip with adjustable magnetic trip setting for fine-tuned protection\u003c\/li\u003e\n\u003cli\u003e25kA AIC at 240VAC (18kA @ 480VAC, 14kA @ 600VAC, 20kA @ 250VDC)\u003c\/li\u003e\n\u003cli\u003eVisi-Trip indicator for fast visual fault identification\u003c\/li\u003e\n\u003cli\u003eI-Line mounting style, compatible with Square D I-Line panelboards and switchboards\u003c\/li\u003e\n\u003cli\u003eUL 489 listed, HACR rated, current limiting, mercury-free and RoHS compliant\u003c\/li\u003e\n\u003cli\u003eDirect replacement for the discontinued Square D KA36200\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJDA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJDA36200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240VAC, 480VAC, 600VAC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAIC Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 20kA @ 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFor Use With\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D I-Line Panelboards, Switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Function Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLI (Long-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Adjustability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed Thermal, Adjustable Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/0 AWG - 350 kcmil (Al\/Cu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lugs Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCCC, CE, CSA, IEC, NOM, UKCA, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25C to 70C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHACR Rated, Current Limiting, Visual Trip Indicator, Non-Interchangeable Trip, Reverse Feed, Mercury Free, RoHS Compliant, PVC Free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Square D JDA36200 used for?\u003c\/strong\u003e\u003cbr\u003eIt protects 200A, 3-pole electrical circuits from overcurrent and short-circuit faults in commercial and industrial systems using Square D I-Line panelboards or switchboards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the JDA36200 a replacement for the KA36200?\u003c\/strong\u003e\u003cbr\u003eYes. The JDA36200 is Square D's designated direct replacement for the discontinued KA36200, so it installs into existing I-Line equipment without modification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the AIC rating of the JDA36200?\u003c\/strong\u003e\u003cbr\u003e25kA at 240VAC, 18kA at 480VAC, 14kA at 600VAC, and 20kA at 250VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the JDA36200 have an adjustable trip?\u003c\/strong\u003e\u003cbr\u003eYes, it has a fixed thermal trip and an adjustable magnetic trip setting.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":50144096944376,"sku":"JDA36200","price":914.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/1111_c558a64a-6073-4074-8c30-12ef7c5c4abc.webp?v=1786487330","url":"https:\/\/alphabreakersandcontrols.com\/products\/jda36200-square-d-molded-case-circuit-breaker-i-line-plug-in-200-amp-3-pole-600-volt","provider":"Alpha Breakers \u0026 Controls","version":"1.0","type":"link"}