{"product_id":"na2p100-federal-pacific-100-amp-circuit-breaker-plug-in-100-amp-2-pole-240-volt","title":"NA2P100 - Federal Pacific - Stab-Lok Plug-In Circuit Breaker - 100 Amp - 2 Pole - 240 Volt (Used)","description":"\u003cp\u003e\u003cstrong\u003eThe Federal Pacific NA2P100 is a 100A, 2-pole thermal-magnetic Stab-Lok plug-in circuit breaker rated 120\/240VAC, sized full-width at one inch per pole for original FPE Stab-Lok load centers.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eThis unit is sold in used condition and carries a 1-year warranty.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eA 100A two-pole is the typical main or large subfeed position in a residential or small commercial Stab-Lok panel — feeding a subpanel, a range circuit, or a detached structure. Because Federal Pacific ceased production decades ago and the Stab-Lok bus stab is proprietary, no other manufacturer's breaker will seat properly, which makes original NA-series stock the only direct fit. This unit is the full-size body requiring one inch per pole, with common trip linking both poles and a color-coded handle. Rated 10kA at 120\/240VAC.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFederal Pacific (FPE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eNA — Stab-Lok\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eNA2P100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e120\/240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAIC Rating\u003c\/th\u003e\n\u003ctd\u003e10kA @ 120\/240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Style\u003c\/th\u003e\n\u003ctd\u003ePlug-On (Stab-Lok)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eFederal Pacific Stab-Lok Load Centers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Technology\u003c\/th\u003e\n\u003ctd\u003eThermal Magnetic (LI — Long-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Adjustability\u003c\/th\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWire Range\u003c\/th\u003e\n\u003ctd\u003e#4 AWG – 2\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd\u003eFull Size — 1 inch per pole (2 inches total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable Options\u003c\/th\u003e\n\u003ctd\u003ePadlock Attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eCSA C22.2 No. 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eCSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConstruction Features\u003c\/th\u003e\n\u003ctd\u003eStab-Lok System, Common Trip, HACR Rated, Color-Coded Handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Dimensions\u003c\/th\u003e\n\u003ctd\u003e6 x 6 x 6 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Weight\u003c\/th\u003e\n\u003ctd\u003e3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eUsed — 1 Year Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat condition is this NA2P100 in, and is it warrantied?\u003c\/h3\u003e\n\u003cp\u003eIt is a used unit, tested and sold with a 1-year warranty. Used stock is the practical option for legacy Stab-Lok panels where new-old-stock is scarce.\u003c\/p\u003e\n\u003ch3\u003eWill a breaker from another manufacturer fit my Stab-Lok panel?\u003c\/h3\u003e\n\u003cp\u003eNo. The Stab-Lok bus stab geometry is proprietary to Federal Pacific. Only NA-series breakers or listed Stab-Lok replacements will seat correctly and make proper contact.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between full-size and thin Stab-Lok breakers?\u003c\/h3\u003e\n\u003cp\u003eStab-Lok was produced in both a full-size body at one inch per pole and a narrower thin body. They are not interchangeable in all panel positions. The NA2P100 is the full-size format.\u003c\/p\u003e\n\u003ch3\u003eAre there known concerns with Federal Pacific Stab-Lok panels?\u003c\/h3\u003e\n\u003cp\u003eYes. Stab-Lok breakers have been the subject of long-standing reports and litigation regarding failure-to-trip under fault conditions, and many inspectors and insurers recommend full panel replacement rather than continued service. Have the installation evaluated by a licensed electrician before deciding between repair and replacement.\u003c\/p\u003e\n\u003ch3\u003eWhat is the interrupting rating of the NA2P100?\u003c\/h3\u003e\n\u003cp\u003e10kA at 120\/240VAC.\u003c\/p\u003e\n\u003ch3\u003eWhat wire sizes does the NA2P100 accept?\u003c\/h3\u003e\n\u003cp\u003e#4 AWG through 2\/0 AWG conductors.\u003c\/p\u003e\n\u003ch3\u003eDoes the NA2P100 have common trip?\u003c\/h3\u003e\n\u003cp\u003eYes. Both poles are internally linked, so a fault on either pole opens the full two-pole circuit.\u003c\/p\u003e\n\u003ch3\u003eCan the NA2P100 be used as a main breaker?\u003c\/h3\u003e\n\u003cp\u003eIn load centers designed with a 100A main breaker position, yes. Verify the panel label for the acceptable main device before installing.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003e1 YEAR WARRANTY\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eBacked by a full 1-year warranty against manufacturing defects. If your product experiences any issues within this period, contact us for repair, replacement, or support.\u003c\/p\u003e","brand":"Federal Pacific","offers":[{"title":"Used","offer_id":50162364186872,"sku":"NA2P100-U","price":149.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/21DAxcSRnCL.jpg?v=1786727930","url":"https:\/\/alphabreakersandcontrols.com\/products\/na2p100-federal-pacific-100-amp-circuit-breaker-plug-in-100-amp-2-pole-240-volt","provider":"Alpha Breakers \u0026 Controls","version":"1.0","type":"link"}