{"product_id":"square-d-hga36110-3-pole-non-interchangeable-trip-thermal-magnetic-circuit-breakers","title":"HGA36110 - Square D - Molded Case Circuit Breaker I-Line Plug-In - 110 Amp - 3 Pole - 600 Volt","description":"\u003ch2\u003eSquare D HGA36110 – 110 Amp Molded Case Circuit Breaker, I-Line Plug-In\u003c\/h2\u003e\u003cp\u003eEngineered for commercial and industrial applications, the \u003cstrong\u003eSquare D HGA36110\u003c\/strong\u003e provides 110A of 3-pole protection within the PowerPacT H-Frame family. It features a thermal-magnetic trip unit delivering long-time and instantaneous (LI) protection and installs into Square D I-Line panelboards and switchboards.\u003c\/p\u003e\u003cp\u003eThe HGA36110 replaces legacy KA36110 and KH36110 breakers. Rated 35 kAIC at 480VAC, it includes current-limiting capabilities and a Visi-Trip indicator.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D \/ Schneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHGA (PowerPacT H-Frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHGA36110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmperage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e110A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e208Y\/120VAC, 240VAC, 480Y\/277VAC, 480VAC, 600Y\/347VAC, 600VAC, 250VDC, 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAIC Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e65kA @ 208Y\/120VAC \u0026amp; 240VAC, 35kA @ 480Y\/277VAC \u0026amp; 480VAC, 18kA @ 600Y\/347VAC \u0026amp; 600VAC, 20kA @ 250VDC \u0026amp; 500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eI-Line Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFor Use With\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSquare D I-Line Panelboards, Switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal Magnetic (Non-Interchangeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTrip Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLI – Long-Time, Instantaneous (Fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWire Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG – 3\/0 AWG (Al\/Cu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable Options\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccessories\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eLoad Side Lugs (AL150HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApprovals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, CSA, IEC, NOM, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemp Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstruction Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHACR Rated, Current Limiting, Reverse Feed, Non-Interchangeable Trip, 80% Rated, Visual Trip Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003chr\u003e\u003ch2\u003eWhy Choose the Square D HGA36110?\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect KA36110 \/ KH36110 Replacement:\u003c\/strong\u003e Legacy-compatible upgrade path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limiting Design:\u003c\/strong\u003e Reduces fault energy let-through.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e80% Rated, HACR Rated:\u003c\/strong\u003e Suited for continuous commercial and HVAC loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisi-Trip Indicator:\u003c\/strong\u003e Fast visual fault identification.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eCommon Applications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCommercial and industrial power distribution panels\u003c\/li\u003e\n\u003cli\u003eHVAC and mechanical equipment feeders\u003c\/li\u003e\n\u003cli\u003eKA36110 \/ KH36110 panelboard upgrades\u003c\/li\u003e\n\u003cli\u003eManufacturing and process control systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat panels is the HGA36110 compatible with?\u003c\/strong\u003e\u003cbr\u003eSquare D I-Line panelboards and switchboards that accept plug-in breakers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the interrupting rating of the HGA36110?\u003c\/strong\u003e\u003cbr\u003e35 kA at 480Y\/277VAC and 480VAC, 65 kA at 208Y\/120VAC and 240VAC, and 18 kA at 600VAC.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat does the HGA36110 replace?\u003c\/strong\u003e\u003cbr\u003eLegacy KA36110 and KH36110 breakers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat lugs does it include?\u003c\/strong\u003e\u003cbr\u003eAL150HD load side lugs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this a new unit?\u003c\/strong\u003e\u003cbr\u003eYes — this listing (SKU HGA36110-N) is new-in-box and ready for immediate installation.\u003c\/p\u003e","brand":"Square D \/ Schneider Electric","offers":[{"title":"New","offer_id":48395672748280,"sku":"HGA36110-N","price":1594.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/HGA36110-1.webp?v=1789187681","url":"https:\/\/alphabreakersandcontrols.com\/products\/square-d-hga36110-3-pole-non-interchangeable-trip-thermal-magnetic-circuit-breakers","provider":"Alpha Breakers \u0026 Controls","version":"1.0","type":"link"}