{"product_id":"ted136030-ge-molded-case-circuit-breaker-feed-thru-30-amp-3-pole-600-volt","title":"TED136030 - GE - E150 Bolt-On Molded Case Circuit Breaker - 30 Amp - 3 Pole - 600 Volt","description":"\u003cp\u003e\u003cstrong\u003eThe GE TED136030 is a 30A, 3-pole E150-frame molded case circuit breaker with bolt-on mounting, rated 600VAC and built for GE A-Series and Spectra Series panelboards and switchboards.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThirty amps at 600 volts covers most small three-phase motor feeders, transformer primaries, and equipment disconnect circuits in commercial buildings. The TED136030 delivers fixed thermal-magnetic Long-Time and Instantaneous (LI) protection with an 18kA interrupting rating at 480VAC and 14kA at 600VAC. Quick-make\/quick-break contacts and a trip-free mechanism ensure the breaker opens on a fault even if the handle is held closed, and common trip links all three poles so a single-phase fault de-energizes the whole circuit. TCAL12 load lugs are included, and the unit is HACR and HID rated for HVAC and discharge lighting duty.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGE \/ ABB (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eE150 Line, Type TED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePart Number\u003c\/th\u003e\n\u003ctd\u003eTED136030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmperage\u003c\/th\u003e\n\u003ctd\u003e30A (150A frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e600VAC, 480VAC, 240VAC, 500VDC, 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAIC Rating\u003c\/th\u003e\n\u003ctd\u003e18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC (UL 489)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting Style\u003c\/th\u003e\n\u003ctd\u003eBolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFor Use With\u003c\/th\u003e\n\u003ctd\u003eGE A-Series Panelboards, GE Spectra Series Panelboards, Switchboards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Technology\u003c\/th\u003e\n\u003ctd\u003eThermal Magnetic (LI — Long-Time, Instantaneous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTrip Adjustability\u003c\/th\u003e\n\u003ctd\u003eFixed Thermal \/ Fixed Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWire Range\u003c\/th\u003e\n\u003ctd\u003e#14–3 AWG (Cu), #12–1 AWG (Al)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAccessories Included\u003c\/th\u003e\n\u003ctd\u003eTCAL12 Load Lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable Options\u003c\/th\u003e\n\u003ctd\u003eShunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL 489, CSA C22.2 No. 5, NEMA AB 1, HACR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eApprovals\u003c\/th\u003e\n\u003ctd\u003eUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConstruction Features\u003c\/th\u003e\n\u003ctd\u003eHACR Rated, HID Rated, Common Trip, Quick-Make\/Quick-Break, Trip-Free Mechanism, Reverse Feed Capable, Non-Interchangeable Trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Dimensions\u003c\/th\u003e\n\u003ctd\u003e10 x 8 x 8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping Weight\u003c\/th\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the difference between the TED136030 and the TED136030WL?\u003c\/h3\u003e\n\u003cp\u003eThe WL suffix designates a factory catalog number that ships with wire lugs installed. Electrically and mechanically the breakers are identical; both units listed here include TCAL12 lugs.\u003c\/p\u003e\n\u003ch3\u003eWhat is the interrupting rating of the TED136030?\u003c\/h3\u003e\n\u003cp\u003e18kA at 240VAC and 480VAC, 14kA at 600VAC, and 10kA at 250VDC and 500VDC.\u003c\/p\u003e\n\u003ch3\u003eHow does the TED differ from the THED?\u003c\/h3\u003e\n\u003cp\u003eThe THED is the high-interrupting version of the same E150 frame, rated 25kA at 480VAC and 65kA at 240VAC versus the TED's 18kA. Choose based on the available fault current at the panel.\u003c\/p\u003e\n\u003ch3\u003eWhat does trip-free mean?\u003c\/h3\u003e\n\u003cp\u003eThe mechanism will open the contacts on an overcurrent even if the operating handle is held in the ON position, so the breaker cannot be defeated manually.\u003c\/p\u003e\n\u003ch3\u003eWhat panelboards accept the TED136030?\u003c\/h3\u003e\n\u003cp\u003eGE A-Series and Spectra Series panelboards and switchboards using bolt-on mounting hardware.\u003c\/p\u003e\n\u003ch3\u003eCan the TED136030 be reverse fed?\u003c\/h3\u003e\n\u003cp\u003eYes. Reverse feed is permitted with no line\/load marking restriction under UL 489.\u003c\/p\u003e\n\u003ch3\u003eIs the 30A trip rating adjustable?\u003c\/h3\u003e\n\u003cp\u003eNo. The trip unit is fixed and non-interchangeable.\u003c\/p\u003e\n\u003ch3\u003eIs the TED136030 UL listed?\u003c\/h3\u003e\n\u003cp\u003eYes. It is UL 489 listed and CSA certified to C22.2 No. 5, and it is HACR rated.\u003c\/p\u003e","brand":"GE","offers":[{"title":"New","offer_id":48395652038904,"sku":"TED136030-N","price":449.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/TED136030-GE-MoldedCaseCircuitBreakerFeed-Thru-30Amp-3Pole-600Volt.webp?v=1786726718","url":"https:\/\/alphabreakersandcontrols.com\/products\/ted136030-ge-molded-case-circuit-breaker-feed-thru-30-amp-3-pole-600-volt","provider":"Alpha Breakers \u0026 Controls","version":"1.0","type":"link"}