{"product_id":"thed136100-ge-molded-case-circuit-breaker-feed-thru-100-amp-3-pole-600-volt","title":"THED136100 - GE - Molded Case Circuit Breaker Feed-Thru - 100 Amp - 3 Pole - 600 Volt","description":"\u003cdiv class=\"product-description\"\u003e\n\u003cp\u003eThe General Electric THED136100 is a 3-pole, 100-amp molded case circuit breaker rated for 600V AC, built for reliable overcurrent protection in industrial and commercial electrical systems. Part of GE's E150 Line, this THED-series breaker uses thermal magnetic (LI) trip technology in a Feed-Thru, bolt-on configuration, allowing it to pass power through a panel section to a secondary compartment — a common setup in switchboards and panelboards that need through-feed distribution. Long-time and instantaneous trip functions guard connected loads against both sustained overloads and short-circuit faults, while an interrupting rating up to 65kA at 240V and 25kA at 480V gives it the fault-clearing capacity industrial panels demand. Every unit ships new and UL listed, ready to install.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eTHED136100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries \/ Family\u003c\/td\u003e\n\u003ctd\u003eTHED, E150 Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eMolded case, fixed thermal magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eFeed-Thru, Bolt-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e100 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e600V AC (120\/240\/277\/480 VAC; 125\/250 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupting Rating (AIC)\u003c\/td\u003e\n\u003ctd\u003e65 kA @ 240VAC · 25 kA @ 480VAC · 10 kA @ 250VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Functions\u003c\/td\u003e\n\u003ctd\u003eLI — Long-Time \u0026amp; Instantaneous (Thermal Magnetic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Type\u003c\/td\u003e\n\u003ctd\u003eNon-interchangeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eAluminum\/Copper Line \u0026amp; Load Lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 4-1\/8\" W x 3-3\/8\" D x 6-5\/16\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003eWhat is the GE THED136100 used for?\u003c\/h3\u003e\n\u003cp\u003eIt's used to provide 3-phase overcurrent protection on 600V-class electrical systems, typically as a feeder or main breaker in industrial and commercial panelboards and switchboards.\u003c\/p\u003e\n\n\u003ch3\u003eWhat does \"Feed-Thru\" mean on this breaker?\u003c\/h3\u003e\n\u003cp\u003eFeed-Thru refers to a mounting configuration that lets power pass through the breaker's compartment to a downstream section of the panel, rather than terminating there — useful in switchboards that need to distribute power to additional sections.\u003c\/p\u003e\n\n\u003ch3\u003eWhat is the interrupting rating of the THED136100?\u003c\/h3\u003e\n\u003cp\u003eIt's rated to interrupt up to 65kA at 240VAC, 25kA at 480VAC, and 10kA at 250VDC, giving it enough fault-clearing capacity for most industrial 480V distribution systems.\u003c\/p\u003e\n\n\u003ch3\u003eIs the GE THED136100 UL listed?\u003c\/h3\u003e\n\u003cp\u003eYes. It's UL listed and suitable for HACR (heating, air conditioning, and refrigeration) duty applications.\u003c\/p\u003e\n\n\u003ch3\u003eDoes this breaker use a fixed or interchangeable trip unit?\u003c\/h3\u003e\n\u003cp\u003eIt uses a non-interchangeable thermal magnetic trip unit, meaning the trip settings are factory-fixed rather than field-adjustable.\u003c\/p\u003e\n\n\u003ch3\u003eIs this a new or refurbished unit?\u003c\/h3\u003e\n\u003cp\u003eThis listing is for a new GE THED136100, not a reconditioned or surplus unit.\u003c\/p\u003e","brand":"Alpha Brokers \u0026 Controls","offers":[{"title":"New","offer_id":48395561599224,"sku":"THED136100-N","price":708.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0826\/1209\/3176\/files\/THED136100-R_a36d1964-4901-46b0-b4ae-82f9da259b81.webp?v=1778784604","url":"https:\/\/alphabreakersandcontrols.com\/products\/thed136100-ge-molded-case-circuit-breaker-feed-thru-100-amp-3-pole-600-volt","provider":"Alpha Breakers \u0026 Controls","version":"1.0","type":"link"}