FAL36060 - Square D - Molded Case Circuit Breaker Feed-Thru - 60 Amp - 3 Pole - 600 Volt
Product images are representative only. Actual product may vary.
Square D FAL36060 – 60 Amp Molded Case Circuit Breaker, Unit Mount / Feed-Thru
Part of the legacy F-Frame series, the Square D FAL36060 is a 60A MCCB providing reliable thermal-magnetic protection for commercial systems. It features a 600VAC maximum rating and handles 18 kAIC at 480V.
Built for unit-mount configurations, the device fastens into Square D enclosures and switchboards using standard lugs. It serves as an exact match for existing FAL installations, and although superseded by the HDL36060, it remains essential for maintaining older infrastructure without panel modifications.
Product Specifications
| Brand | Square D / Schneider Electric |
| Series | FAL (Legacy F-Frame) |
| Part Number | FAL36060 |
| Amperage | 60A |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Poles | 3 |
| AIC Rating | 25kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC |
| Mounting Style | Unit Mount / Feed-Thru |
| Terminal Type | Lugs |
| For Use With | Square D Enclosures, Switchboards, Panelboards |
| Trip Technology | Thermal Magnetic (Fixed) |
| Trip Function | LI – Long-Time, Instantaneous |
| Wire Range | 14-1/0 AWG (Cu), 12-1/0 AWG (Al) |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
| Standards | HACR, IEC 60947-2, NEMA AB 1, UL 489 |
| Approvals | CSA, IEC, UL |
| Temp Rating | 40°C |
| Construction Features | HACR Rated, Visual Trip Indicator |
Why Choose the Square D FAL36060?
- Exact FAL Match: Direct replacement for existing FAL installations.
- Unit-Mount Versatility: Fits enclosures, switchboards, and panelboards.
- HACR Rated: Suited for HVAC circuit applications.
- HDL36060 Upgrade Path: Available when modernizing infrastructure.
Common Applications
- Legacy enclosure and switchboard maintenance
- HVAC and mechanical equipment feeders
- Older infrastructure upkeep without panel modification
- Industrial power distribution
Frequently Asked Questions
What is the FAL36060 designed to replace?
It's an exact match for existing FAL installations, later superseded by the HDL36060.
What is the interrupting rating of the FAL36060?
18 kA at 480VAC, 25 kA at 240VAC, 14 kA at 600VAC, and 10 kA at 250VDC.
How does the FAL36060 mount?
Unit mount / feed-thru, into Square D enclosures, switchboards, and panelboards.
What wire sizes does it accept?
14–1/0 AWG copper or 12–1/0 AWG aluminum.
Is this a new unit?
Yes — this listing (SKU FAL36060-N) is new-in-box and ready for immediate installation.