The Square D HJA36125 is a 125A, 3-pole PowerPacT H-Frame molded case circuit breaker with an I-Line plug-in line-side connection, rated 600VAC and built for Square D I-Line panelboards and switchboards.

At 125 amps this is the top of the H-Frame 150A frame's common feeder range, delivering thermal-magnetic Long-Time and Instantaneous (LI) protection with a 65kA interrupting rating at 480VAC and 100kA at 240VAC. Current-limiting construction cuts peak let-through energy during a short circuit, which protects downstream conductors and supports series-rated combinations. The breaker plugs directly onto the I-Line bus with ABC phase sequence and ships with mechanical load lugs accepting up to 3/0 AWG. A Visi-Trip indicator distinguishes a fault trip from a manual open.

Specifications

Brand Square D / Schneider Electric
Series PowerPacT H-Frame, I-Line, Type HJ
Part Number HJA36125
Amperage 125A (150A frame)
Voltage 600VAC, 480VAC, 240VAC, 250VDC
Poles 3
Phase 3
AIC Rating 100kA @ 240VAC, 65kA @ 480VAC, 25kA @ 600VAC, 20kA @ 250VDC (UL 489)
Mounting Style I-Line Plug-In
Terminal Type I-Line jaws on line side, mechanical lugs on load side
Phase Sequence ABC
Continuous Current Rating 80%
For Use With Square D I-Line Panelboards and Switchboards
Trip Technology Thermal Magnetic (LI — Long-Time, Instantaneous)
Trip Adjustability Fixed Thermal / Fixed Magnetic
Wire Range #14 AWG – 3/0 AWG (Al/Cu)
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment
Standards UL 489, CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, RoHS, REACh, HACR
Approvals UL, CSA, CE, IEC, NEMA, NOM
Construction Features Current Limiting, HACR Rated, Visi-Trip Indicator, Reverse Feed Capable, Non-Interchangeable Trip
Operating Temperature -25°C to 70°C
Shipping Dimensions 16 x 10 x 10 in
Shipping Weight 9 lb
Condition New

Frequently Asked Questions

What is the interrupting rating of the HJA36125?

65kA at 480VAC, 100kA at 240VAC, 25kA at 600VAC, and 20kA at 250VDC.

What does HJA36125 stand for?

H = PowerPacT H-Frame, J = 65kA interrupting rating at 480VAC, A = I-Line plug-in with ABC phase sequence, 3 = 3 poles, 6 = 600V class, and 125 = 125 amps.

Is the HJA36125 trip setting adjustable?

No. It uses a fixed thermal and fixed magnetic (LI) trip unit that is non-interchangeable, so the 125A rating is permanent.

What panelboards does the HJA36125 fit?

Square D I-Line panelboards and switchboards. The I-Line jaws plug directly onto the bus with ABC phase sequence.

Is the HJA36125 current limiting?

Yes. It limits peak let-through current and I²t during a short circuit, reducing stress on downstream conductors and equipment.

What wire sizes do the load lugs accept?

The supplied mechanical lugs accept #14 AWG through 3/0 AWG aluminum or copper conductors.

What is the continuous load limit for the HJA36125?

At 80% rating, continuous loads should not exceed 100 amps unless applied in an assembly listed for 100% continuous duty.

Is the HJA36125 UL listed?

Yes. It is UL 489 listed and also certified to CSA C22.2 No. 5, IEC 60947-2, and NOM, with CE marking and RoHS/REACh compliance.