HJA36040 - Square D - PowerPacT H I-Line Molded Case Circuit Breaker - 40 Amp - 3 Pole - 600 Volt
Product images are representative only. Actual product may vary.
The Square D HJA36040 is a 40A, 3-pole PowerPacT H-Frame molded case circuit breaker with an I-Line plug-in line-side connection, rated 600VAC and built for Square D I-Line panelboards and switchboards.
This thermal-magnetic breaker delivers Long-Time and Instantaneous (LI) protection with a 65kA interrupting rating at 480VAC and 100kA at 240VAC. Unlike the smaller frame sizes, the 40A HJA offers an adjustable magnetic trip, letting you raise the instantaneous pickup to ride through motor inrush without nuisance tripping while keeping the thermal element fixed at 40A. Its current-limiting construction cuts peak let-through energy during a fault, and the H-Frame retrofits into the same I-Line mounting space as the discontinued FC36040 and FH36040. HID and HACR rated for lighting and HVAC branch circuits.
Specifications
| Brand | Square D / Schneider Electric |
|---|---|
| Series | PowerPacT H-Frame, I-Line, Type HJ |
| Part Number | HJA36040 |
| Amperage | 40A (150A frame) |
| Voltage | 600VAC, 480VAC, 240VAC, 250VDC |
| Poles | 3 |
| Phase | 3 |
| AIC Rating | 100kA @ 240VAC, 65kA @ 480VAC, 25kA @ 600VAC, 20kA @ 250VDC (UL 489) |
| Mounting Style | I-Line Plug-In |
| Terminal Type | I-Line jaws on line side, mechanical lugs on load side |
| Phase Sequence | ABC |
| Continuous Current Rating | 80% |
| For Use With | Square D I-Line Panelboards and Switchboards |
| Trip Technology | Thermal Magnetic (LI — Long-Time, Instantaneous) |
| Trip Adjustability | Fixed Thermal / Adjustable Magnetic |
| Wire Range | #14 AWG – 3/0 AWG (Al/Cu) |
| Replaces | Square D FC36040, FH36040 |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Handle Padlock Attachment |
| Standards | UL 489, CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1 |
| Approvals | UL, CSA, CE, IEC, NOM |
| Construction Features | Current Limiting, HACR Rated, HID Rated, Non-Interchangeable Trip, Visi-Trip Indicator |
| Operating Temperature | -25°C to 70°C |
| Shipping Dimensions | 14 x 10 x 10 in |
| Shipping Weight | 8 lb |
| Condition | New |
Frequently Asked Questions
What is the interrupting rating of the HJA36040?
65kA at 480VAC, 100kA at 240VAC, 25kA at 600VAC, and 20kA at 250VDC.
Is the magnetic trip on the HJA36040 adjustable?
Yes. The 40A HJA has a field-adjustable instantaneous magnetic pickup, which is useful for motor and transformer circuits with high inrush. The thermal (long-time) element remains fixed at 40A.
What does HJA36040 stand for?
H = PowerPacT H-Frame, J = 65kA interrupting rating at 480VAC, A = I-Line plug-in with ABC phase sequence, 3 = 3 poles, 6 = 600V class, and 040 = 40 amps.
Which older Square D breakers does the HJA36040 replace?
It is the designated replacement for the discontinued FC36040 and FH36040, and it fits the same I-Line mounting space.
Is the HJA36040 HID rated?
Yes. It is rated for high-intensity discharge lighting circuits as well as HACR heating, air conditioning, and refrigeration equipment.
What wire sizes will the load lugs accept?
The supplied mechanical lugs accept #14 AWG through 3/0 AWG aluminum or copper conductors.
What is the continuous load limit for the HJA36040?
At 80% rating, continuous loads should not exceed 32 amps unless the breaker is applied in an assembly listed for 100% continuous duty.
Is the HJA36040 UL listed?
Yes. It is UL 489 listed and also certified to CSA C22.2 No. 5, IEC 60947-2, and NOM, with CE marking.